EGT logging
#1
Elite Member
Thread Starter
iTrader: (15)
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,847
Total Cats: 27
EGT logging
So I have a new manifold with a bung for an EGT probe. I plan on taking the proven/usual approach using a thermocouple probe. The question is, what to use to condition the signal, and how to get it into the Adaptronic?
There are a few thermocouple amplifiers out there that will take an input and convert it to a analog and/or digital signal. Innovate makes one, but it has 4 input channels (overkill) and may not have a 0-5V out; I have not torn into the manual yet. Plus it is $130. Anyone got an idea on a good 1-channel TC amplifier, with a 0-5V output, that runs on 12V? Not looking to build a conditioner, would rather buy one off-the-shelf.
As far as how to connect to the Adaptronic, I am already using the serial port for the Innovate LC-1 WB02, so I think that is out unless there is a cheap and easy way to connect both at the same time. So I think that means I need an analog output from the TC conditioner to connect to the Adaptronic. Any suggestions there?
I poked around the Adaptronic site and did not see anything in particular. If it is there, I missed it.
There are a few thermocouple amplifiers out there that will take an input and convert it to a analog and/or digital signal. Innovate makes one, but it has 4 input channels (overkill) and may not have a 0-5V out; I have not torn into the manual yet. Plus it is $130. Anyone got an idea on a good 1-channel TC amplifier, with a 0-5V output, that runs on 12V? Not looking to build a conditioner, would rather buy one off-the-shelf.
As far as how to connect to the Adaptronic, I am already using the serial port for the Innovate LC-1 WB02, so I think that is out unless there is a cheap and easy way to connect both at the same time. So I think that means I need an analog output from the TC conditioner to connect to the Adaptronic. Any suggestions there?
I poked around the Adaptronic site and did not see anything in particular. If it is there, I missed it.
#3
Elite Member
Thread Starter
iTrader: (15)
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,847
Total Cats: 27
Yeah forgot to mention the gauge thing. I do not have another spot to put one and really do not want to anyway. If I cannot find a way to log it, I will probably just use a handheld meter with a thermocouple reader, like at the dyno during tuning for example.
The adaptronic may not read an EGT natively, but if I can at least log the voltage I can always convert it later. Plus it will be synched with the rest of the logged data.
The adaptronic may not read an EGT natively, but if I can at least log the voltage I can always convert it later. Plus it will be synched with the rest of the logged data.