Engine Performance This section is for discussion on all engine building related questions.
Sponsored by:
Sponsored by: KPower

ARP head stud torque for a Miata.

Thread Tools
 
Search this Thread
 
Old 01-21-2011, 06:49 PM
  #41  
Junior Member
iTrader: (4)
 
Larimer's Avatar
 
Join Date: May 2009
Location: Novi, MI
Posts: 308
Total Cats: 1
Default

haha, I should just do a quick FEA of it next time I'm bored at work.
Larimer is offline  
Old 01-21-2011, 09:56 PM
  #42  
Junior Member
iTrader: (3)
 
RavynX's Avatar
 
Join Date: Apr 2010
Location: San Antonio, TX
Posts: 410
Total Cats: 1
Default

I'll be putting the head back on my car this weekend hopefully. I'm planning on torquing them to 65 ft lbs as well.
RavynX is offline  
Old 01-26-2011, 04:40 PM
  #43  
AFM Crusader
iTrader: (19)
 
olderguy's Avatar
 
Join Date: Oct 2004
Location: Wayne, NJ
Posts: 4,666
Total Cats: 336
Default

Found this today with some old papers in the garage. Installed mine before this thread started and probably followed the instructions. Guess I will just need to wait and see what happens.
Attached Thumbnails ARP head stud torque for a Miata.-arp-studs.jpg  
olderguy is offline  
Old 02-03-2011, 04:31 AM
  #44  
Newb
 
tbro's Avatar
 
Join Date: Sep 2010
Location: Brisbane Queensland
Posts: 10
Total Cats: 0
Default

Received an email from ARP after the floods destroyed all our build diarys,

Sorry to hear you lost some things in the flood! Here are the torque
numbers you need. They are the same for both the ARP Ultra Torque and
ARP Moly Lube.

Rod Bolts 118-6401 = 38 ft/lbs
Head Studs 218-4701 = 80 ft/lbs
Main Studs 218-5401 = 60 ft/lbs

Regards,

Alan Nichols
Sales & Technical

Automotive Racing Products
1863 Eastman Ave.
Ventura, CA 93003
Toll Free: 800-826-3045
Ph: 805-339-2200
Fax: 805-650-0742
Email: alann@arpfasteners.com
www.arp-bolts.com



So I think I follow Savs recommendations

Terry
tbro is offline  
Old 02-03-2011, 12:45 PM
  #45  
Elite Member
Thread Starter
 
bbundy's Avatar
 
Join Date: Jul 2005
Location: Anacortes, WA
Posts: 2,478
Total Cats: 144
Default

Originally Posted by tbro
Received an email from ARP after the floods destroyed all our build diarys,

Sorry to hear you lost some things in the flood! Here are the torque
numbers you need. They are the same for both the ARP Ultra Torque and
ARP Moly Lube.

Rod Bolts 118-6401 = 38 ft/lbs
Head Studs 218-4701 = 80 ft/lbs
Main Studs 218-5401 = 60 ft/lbs

Regards,

Alan Nichols
Sales & Technical

Automotive Racing Products
1863 Eastman Ave.
Ventura, CA 93003
Toll Free: 800-826-3045
Ph: 805-339-2200
Fax: 805-650-0742
Email: alann@arpfasteners.com
www.arp-bolts.com



So I think I follow Savs recommendations

Terry
I am pretty sure 80 is way too much for our aluminum heads. The original ARP engineer who set up the studs for the application said 48 I believe and the stock specs for the OE bolts which should provide a lot less clamp force per torque amount is 56-60.

Bob

Last edited by bbundy; 02-03-2011 at 01:06 PM.
bbundy is offline  
Old 02-13-2011, 02:15 PM
  #46  
Senior Member
iTrader: (23)
 
Jfornachon's Avatar
 
Join Date: Oct 2009
Location: Chatsworth, SoCal
Posts: 948
Total Cats: 1
Default

So if the head bolt spec is off then what should the rod and main bolts be torque to? I am about to rebuild my engine.

Have a great day,
Jared
Jfornachon is offline  
Old 02-13-2011, 04:33 PM
  #47  
Elite Member
iTrader: (18)
 
astroboy's Avatar
 
Join Date: Dec 2007
Location: oahu
Posts: 1,787
Total Cats: 6
Default

Originally Posted by bbundy
ARP studs also have smaller OD washers than stock which isnt helping things.
Bob
Would there be benefits to using oe sized washers with the head stud kit? Perhaps the higher torque numbers would not damage the head with more area under the washer for said tq to be exerted onto or would it be such a small increase in od that no difference would be realized?
astroboy is offline  
Old 02-14-2011, 11:50 AM
  #48  
Junior Member
iTrader: (4)
 
Larimer's Avatar
 
Join Date: May 2009
Location: Novi, MI
Posts: 308
Total Cats: 1
Default

I haven't seen the size difference but any time you can increase the area that will reduce the pressure/stress exerted on the face. Even small changes in area should produce a decently reduced stress. P=F/A
Larimer is offline  
Old 02-14-2011, 12:31 PM
  #49  
Elite Member
Thread Starter
 
bbundy's Avatar
 
Join Date: Jul 2005
Location: Anacortes, WA
Posts: 2,478
Total Cats: 144
Default

Originally Posted by Larimer
I haven't seen the size difference but any time you can increase the area that will reduce the pressure/stress exerted on the face. Even small changes in area should produce a decently reduced stress. P=F/A
I can probably take some pictures tonight. I ditch the ARP washers and use OEM ones. They appear to be the same hardness but the OEM ones have a significantly bigger OD.

Bob
bbundy is offline  
Old 02-14-2011, 01:54 PM
  #50  
Senior Member
iTrader: (1)
 
Cococarbine3's Avatar
 
Join Date: Jul 2009
Location: Batavia, IL
Posts: 601
Total Cats: 0
Default

I torqued mine to 80ft/lbs a couple years ago, which seemed ridiculous when torquing them down at the time. I have, however, ran the engine without a belt on the water pump for 40 minutes in traffic (Had no water temperature gauge) before the upper radiator hose literally blew off the radiator. In normal cases with factory head studs, this would call for the head to be machined for sure. I just put the hose back on, threw a belt on, filled up, and I haven't lost coolant ever since.
Cococarbine3 is offline  
Old 02-20-2011, 10:35 PM
  #51  
Former Vendor
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

Originally Posted by tbro
Rod Bolts 118-6401 = 38 ft/lbs
Surprising that ARP would tell you this. The ARP2000 bolts that M-Tuned ships with their rods specify a stretch spec, not a torque spec. I've found that in order to get the ~.005-.006" stretch spec (IIRC), they wanted around 55-60ft.lbs of torque, not 38.
Savington is offline  
Old 03-28-2011, 04:35 PM
  #52  
Elite Member
iTrader: (18)
 
astroboy's Avatar
 
Join Date: Dec 2007
Location: oahu
Posts: 1,787
Total Cats: 6
Default

Originally Posted by Savington
Surprising that ARP would tell you this. The ARP2000 bolts that M-Tuned ships with their rods specify a stretch spec, not a torque spec. I've found that in order to get the ~.005-.006" stretch spec (IIRC), they wanted around 55-60ft.lbs of torque, not 38.
When I contacted m-tuned about torquing the rod bolts they specified 40-45ft lbs if not torquing to the stretch value.
astroboy is offline  
Old 10-13-2011, 11:06 AM
  #53  
Elite Member
iTrader: (11)
 
miatauser884's Avatar
 
Join Date: Feb 2009
Posts: 2,959
Total Cats: 11
Default

Sorry to bring this back up. I just pulled the head, and plan on installing the new gasket this weekend. I originally torqued the nuts to 80 ft lbs per the instructions using the arp moly lube. After reading this thread it sounds like 65 lbs is a better option. Do I need to get more arp moly, is there a substitue, and do I need to measure the length of the threads for stretching with a micrometer? Keep in mind the threads had moly only when initially torqued, and now they will probably have a little oil on them. What is the recommendation for this scenario.

EDIT: It appears that ARP is now using the "ultratorque" lube which really minimizes the variance between torque stages. I think I screwed the pooch by tightening once, then immediately checking the torque again then buttoning everything up and never looking back. It appears that a person should probably use 8 separate torque cycles at the desired torque. How many cycles leading up to the desired torque before starting the 8 cycle retorque session? How long between cycles should a person wait before starting the next torque cycle???

Example: Pre torque 25%, 50%, 75%, 100% then 7 more cycles at 100% torque

Last edited by miatauser884; 10-13-2011 at 11:37 AM.
miatauser884 is offline  
Old 10-13-2011, 11:14 AM
  #54  
Tour de Franzia
iTrader: (6)
 
hustler's Avatar
 
Join Date: Jun 2006
Location: Republic of Dallas
Posts: 29,085
Total Cats: 375
Default

Originally Posted by djp0623
Sorry to bring this back up. I just pulled the head, and plan on installing the nw gasket this weekend. I originally torqued the nuts top 80 lbs per the instructions using the arp moly lube. After reading this thread it souns like 65 lbs is a better option. Do I need to get more arp moly, is there a substitue, and do I need to measure the length of the threads for stretching with a micrometer? Keep in mind the threads had moly only when initially torqued, and now they will probably have a little oil on them. What is the recommendation for this scenario.
+1

In for answer.
hustler is offline  
Old 10-14-2011, 10:10 AM
  #55  
Elite Member
iTrader: (11)
 
miatauser884's Avatar
 
Join Date: Feb 2009
Posts: 2,959
Total Cats: 11
Default

Just an FYI. This is why I said eight cycles to tighten. Then if you use assembly lube or motor oil you can be sure that you are getting the torque that you want. It also appears that a torque cycle is defined by tightening to spec, then loosening. I was unaware of this. I thought it meant tighten to spec, wait for any stretching then hit it with the torque wrench again to check. Using ARP assembly would clearly save a bit of time.

miatauser884 is offline  
Old 10-14-2011, 11:39 AM
  #56  
Elite Member
iTrader: (2)
 
miata2fast's Avatar
 
Join Date: Aug 2009
Location: Dover, FL
Posts: 3,143
Total Cats: 174
Default

That is very good info. Thanks for sharing.

I will say that the BP is not known for blowing head gaskets, and unless you are building a mega high horsepower motor, 8 torque cycles, tightening and loosening, and choice of lubircant is not overly important. Clamping a miata head to block is pretty forgiving of discrepencies in technique, with the exception of over torquing which has already been discussed.
miata2fast is offline  
Old 10-14-2011, 04:21 PM
  #57  
Former Vendor
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

There is no time component to fastener stretch. It stretches as soon as you preload it.

8 torque cycles is absolutely ridiculous. Use their recommended lubricant, torque it in 3 steps, and don't untorque it. All you are doing is uncompressing and recompressing the gasket, which is a bad idea.
Savington is offline  
Old 10-14-2011, 04:43 PM
  #58  
Elite Member
iTrader: (11)
 
miatauser884's Avatar
 
Join Date: Feb 2009
Posts: 2,959
Total Cats: 11
Default

Originally Posted by Savington
There is no time component to fastener stretch. It stretches as soon as you preload it.

8 torque cycles is absolutely ridiculous. Use their recommended lubricant, torque it in 3 steps, and don't untorque it. All you are doing is uncompressing and recompressing the gasket, which is a bad idea.
Thanks Sav!
miatauser884 is offline  
Old 04-23-2012, 07:22 PM
  #59  
Junior Member
 
VanMSM's Avatar
 
Join Date: Dec 2006
Location: Vancouver, BC
Posts: 129
Total Cats: 6
Default

Back from the dead.

I just called FM and they say the 48lb ARP head stud number is not used by them anymore. They said 60-65lb for both the ARP head and main studs when using the ARP moly lube.

Why would we want to exceed the OE torque spec and thus clamping force if we know that the ARP studs are already stronger than OE bolts? Isn't the benefit in using the stronger studs? Or is there something to be gained by increasing the clamping force?

I'm reluctant to use ARP main studs at a higher torque if it forces a line bore since it adds $$$ to the build.
VanMSM is offline  
Old 04-25-2012, 11:21 PM
  #60  
Elite Member
iTrader: (9)
 
TravisR's Avatar
 
Join Date: Jun 2008
Location: Houston, TX
Posts: 1,547
Total Cats: 13
Default

The increased yield of the material is of little use in stock preload applications. The modulus of elasticity which would determine the "clampyness factor" is pretty well absolutely constant for most steels. Unless you need a higher torque load on the bolt/stud the additional material strength isn't going to do you any good. In short... the studs should not apply any additional clamping force under stock pre-load. Higher then stock pre-load can cause problems as mentioned...

That being said, the tensioner bolt on my power steering pump broke today. I could just be bitter.
TravisR is offline  


Quick Reply: ARP head stud torque for a Miata.



All times are GMT -4. The time now is 08:31 AM.