General Miata Chat A place to talk about anything Miata

anyone run high temp silicone hose for oil drain line

Thread Tools
 
Search this Thread
 
Old 09-16-2012, 07:12 PM
  #1  
Junior Member
Thread Starter
 
coltonr's Avatar
 
Join Date: Aug 2012
Location: Santa Fe, NM
Posts: 99
Total Cats: -24
Default anyone run high temp silicone hose for oil drain line

So i am looking at a predrilled oil pan with a 5/8in piece in the oil pan. However the fitting is not threaded but the guy who im debating on buying it from says that he ran a high temp hose and just put the hose over the outlet and used a hose clamp to hold the hose and had no leaks.

However i read that the lines should be ss since the heat but the high temp is good to 350F so i just figured i would ask for some opinions.

thanks
coltonr is offline  
Old 09-16-2012, 08:38 PM
  #2  
Elite Member
iTrader: (24)
 
viperormiata's Avatar
 
Join Date: Aug 2008
Location: Key West
Posts: 6,110
Total Cats: 283
Default

Silicone works. Just be ready to replace it when you see signs of stress or fatigue.

If the guy drilled the pan and threaded the fitting in, you should replace the fitting with something else so you can run a SS line.
viperormiata is offline  
Old 09-16-2012, 08:54 PM
  #3  
Ben
Supporting Vendor
iTrader: (33)
 
Ben's Avatar
 
Join Date: Jul 2006
Location: atlanta-ish
Posts: 12,659
Total Cats: 134
Default

I have used silicone with a heat sleeve before. Works fine.

Attached Thumbnails anyone run high temp silicone hose for oil drain line-2_601334702637.jpg  
__________________
Chief of Floor Sweeping, DIYAutoTune.com & AMP EFI
Crew Chief, Car Owner & Least Valuable Driver, HongNorrthRacing

91 Turbo | 10AE Turbo | 01 Track Rat | #323 Mazda Champcar

Originally Posted by concealer404
Buy an MSPNP Pro, you'll feel better.
Ben is offline  
Old 09-16-2012, 09:12 PM
  #4  
Junior Member
Thread Starter
 
coltonr's Avatar
 
Join Date: Aug 2012
Location: Santa Fe, NM
Posts: 99
Total Cats: -24
Default

Originally Posted by viperormiata
Silicone works. Just be ready to replace it when you see signs of stress or fatigue.

If the guy drilled the pan and threaded the fitting in, you should replace the fitting with something else so you can run a SS line.
That's what I was debating on doing in the long run I just wish it was drilled a 5/8th size that seems to be an awkward size to find in order to match with the fitting on the td04 turbo
coltonr is offline  
Old 09-16-2012, 09:14 PM
  #5  
Former Vendor
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

I ran silicone for a while as well. SS is preferable since it will last far longer, but high-temp silicone works.
Savington is offline  
Old 09-16-2012, 10:31 PM
  #6  
Junior Member
Thread Starter
 
coltonr's Avatar
 
Join Date: Aug 2012
Location: Santa Fe, NM
Posts: 99
Total Cats: -24
Default

Originally Posted by Savington
I ran silicone for a while as well. SS is preferable since it will last far longer, but high-temp silicone works.
Awesome thank you

Originally Posted by Ben
I have used silicone with a heat sleeve before. Works fine.

Sounds good thank you
coltonr is offline  
Old 09-17-2012, 01:27 AM
  #7  
Elite Member
iTrader: (2)
 
Faeflora's Avatar
 
Join Date: Jan 2007
Location: Los Angeles, CA
Posts: 8,682
Total Cats: 130
Default

you can also slide ss braid over the bung and clamp. Or the blue push loc hose.
Faeflora is offline  
Old 09-17-2012, 09:54 AM
  #8  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

Same silicone hose since around 2008. I replaced it once, only because it was degarded around where it clamps, and only since I had taken in on/off a few times.
Braineack is offline  
Old 09-17-2012, 11:36 AM
  #9  
Junior Member
Thread Starter
 
coltonr's Avatar
 
Join Date: Aug 2012
Location: Santa Fe, NM
Posts: 99
Total Cats: -24
Default

Originally Posted by Braineack
Same silicone hose since around 2008. I replaced it once, only because it was degarded around where it clamps, and only since I had taken in on/off a few times.
Thank you brain. I was worried that ppl would say to stray from this course but it seems like for 15 dollars for an oil pan pre tapped it seems like a good deal
coltonr is offline  
Old 09-17-2012, 02:47 PM
  #10  
Junior Member
iTrader: (1)
 
mcfandango's Avatar
 
Join Date: Aug 2008
Location: Austin, TX
Posts: 240
Total Cats: 5
Default

I forget exactly what I've used but I haven't changed the hose since 07 when I first built the motor. Got it from a Farm and Tractor Supply hardware store. High Temp hydraulic hose I think. I did put some of the foil sleeve over it. No issues so far. Although I am probably going to do something different when I do the preventative maintenance rebuild this winter.
mcfandango is offline  
Old 09-20-2012, 01:37 PM
  #11  
Junior Member
iTrader: (5)
 
MR.M!474's Avatar
 
Join Date: Nov 2010
Location: Originally from Germany. Now live in SoCal
Posts: 194
Total Cats: -5
Default

meh, id go SS but thats just me. Put it on and forget about it. Its also a bit difficult to check the oil drain line without getting under the car.
MR.M!474 is offline  
Old 09-20-2012, 01:53 PM
  #12  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

I put mine on and forgot about it...

I'm more concerned about the vacuum plug I used to block a coolant port.
Braineack is offline  
Old 09-20-2012, 04:00 PM
  #13  
Senior Member
 
sturovo's Avatar
 
Join Date: Apr 2011
Location: Martin, Slovakia
Posts: 507
Total Cats: 74
Default

Originally Posted by coltonr
That's what I was debating on doing in the long run I just wish it was drilled a 5/8th size that seems to be an awkward size to find in order to match with the fitting on the td04 turbo
I used vulcanizing rubber tape to bump the diameter of the wrx TD04 drain fitting.
sturovo is offline  
Old 09-20-2012, 04:09 PM
  #14  
Elite Member
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default

Silicone hose + fiberglass weave for the last 10k miles. No problems.
Saml01 is offline  
Old 09-20-2012, 04:09 PM
  #15  
Junior Member
Thread Starter
 
coltonr's Avatar
 
Join Date: Aug 2012
Location: Santa Fe, NM
Posts: 99
Total Cats: -24
Default

Originally Posted by sturovo
I used vulcanizing rubber tape to bump the diameter of the wrx TD04 drain fitting.

Tha would work to but.I ended up getting.something.like this which will allow for a cleaner tap of the pan.
Performance Stainless Steel 1001 - Performance Stainless Steel Hose Adapters - Mobile SummitRacing.com
coltonr is offline  
Old 09-20-2012, 08:58 PM
  #16  
Tour de Franzia
iTrader: (6)
 
hustler's Avatar
 
Join Date: Jun 2006
Location: Republic of Dallas
Posts: 29,085
Total Cats: 375
Default


Only $431
Attached Thumbnails anyone run high temp silicone hose for oil drain line-4700-101.jpg  
hustler is offline  
Old 09-20-2012, 10:14 PM
  #17  
Junior Member
Thread Starter
 
coltonr's Avatar
 
Join Date: Aug 2012
Location: Santa Fe, NM
Posts: 99
Total Cats: -24
Default

Originally Posted by hustler

Only $431
dam for that price i def shouldve gone with that! i shouldve gotten a nice twin turbo setup custom built to
coltonr is offline  
Old 09-21-2012, 04:26 AM
  #18  
Senior Member
 
sturovo's Avatar
 
Join Date: Apr 2011
Location: Martin, Slovakia
Posts: 507
Total Cats: 74
Default

Originally Posted by hustler

Only $431
Too bad I didn't see this before committing to my 9$ steel braided setup

[IMG][/IMG]
sturovo is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Andifer
Miata parts for sale/trade
8
09-23-2015 05:43 PM
Voltwings
WTB
5
09-11-2015 08:23 AM
SuperSneakySecretSquirrel
Meet and Greet
5
09-06-2015 08:30 PM
AlwaysBroken
Engine Performance
5
09-06-2015 12:53 AM
itsMikey
Insert BS here
0
09-05-2015 02:56 PM



Quick Reply: anyone run high temp silicone hose for oil drain line