I just purchased a 600w 12v transformer for outdoor lighting. Is the DC load going to directly determine the current draw (similar to AC)? Or is this baby going to suck down 600w no matter what the DC load is? It has an eerie hum with just the AC plugged in with no DC load, and it’s warm, and it’s huge (at least 20#).

Reason I ask: I only have about 200w worth of lighting that I need to power, but I opted for the larger power supply for the possibility of expanding, and it was only $20 more than a unit with half the capacity. Just wondering if the smaller unit would have been notably more efficient (300w unit driving 200w worth of lights versus a 600w unit driving 200w worth of lights)?

Thanks
Slayer is offline  
Old 08-19-2011, 12:18 PM
  #2  
Senior Member
iTrader: (1)
 
revlimiter's Avatar
 
Join Date: Jan 2009
Location: ABQ, NM
Posts: 518
Total Cats: 95
Default

awww. I got all excited.

revlimiter is offline  
Old 08-19-2011, 12:26 PM
  #3  
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Chicago. (The less-murder part.)
Posts: 33,019
Total Cats: 6,587
Default

Originally Posted by Slayer
I just purchased a 600w 12v transformer for outdoor lighting. Is the DC load going to directly determine the current draw (similar to AC)? Or is this baby going to suck down 600w no matter what the DC load is?
Current draw will vary with load.

More lights = more current on the AC side.

The wattage rating on the transformer indicates the maximum that it can supply before it blows up.


It has an eerie hum with just the AC plugged in with no DC load, and it’s warm, and it’s huge (at least 20#).
Yup. Transformers are not 100% efficient. They draw a small amount of current even with no load.

If you were to measure a transformer's primary winding with a regular DC ohmmeter, it would appear to be a dead short. It's just a big coil of wire connected directly across both legs of the AC supply. The reason it doesn't immediately catch on fire and blow a fuse is because it has a very large AC impedance, and impedance is basically a resistance to change in the flow of current (it's sort of like resistance, but applicable to AC only.) If you were to feed 120v DC into it, it would melt and catch on fire. This is the big reason why Westinghouse beat Edison in the War of the Currents- you can run AC it into transformers, and the electromagnetic properties of the transformer cause it to magically load-follow. With DC, you can't do passive voltage conversion.

Those poor elephants...



Just wondering if the smaller unit would have been notably more efficient (300w unit driving 200w worth of lights versus a 600w unit driving 200w worth of lights)?
Very slightly, but you're not likely to notice it on your power bill.
Joe Perez is offline  
Old 08-19-2011, 12:39 PM
  #4  
Ben
Supporting Vendor
iTrader: (33)
 
Ben's Avatar
 
Join Date: Jul 2006
Location: atlanta-ish
Posts: 12,659
Total Cats: 134
Default

P = I * I * R
Where P = power (measured in watts)
I = current (measured in amps)
R = resistance (measured in ohms)

So power varies with load.
__________________
Chief of Floor Sweeping, DIYAutoTune.com & AMP EFI
Crew Chief, Car Owner & Least Valuable Driver, HongNorrthRacing

91 Turbo | 10AE Turbo | 01 Track Rat | #323 Mazda Champcar

Originally Posted by concealer404
Buy an MSPNP Pro, you'll feel better.
Ben is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
bigmackloud
Miata parts for sale/trade
19
01-08-2021 11:24 AM
Quinn
Cars for sale/trade
6
10-23-2016 07:58 AM
Joe Perez
Current Events, News, Politics
8
09-30-2015 04:41 PM
JesseTheNoob
DIY Turbo Discussion
15
09-30-2015 02:44 PM
skipstr
Miata parts for sale/trade
2
09-28-2015 10:53 PM



Quick Reply: Question about transformers (DC, not robot)



All times are GMT -4. The time now is 10:12 PM.