Build Threads Building a motor? Post the progress here.

Trackspeed's '02SE "Acamas" - EFR6758, TSE motor, 500whp or bust

Thread Tools
 
Search this Thread
 
Old 12-07-2016, 05:40 PM
  #341  
Elite Member
iTrader: (1)
 
Chiburbian's Avatar
 
Join Date: Feb 2008
Location: Loganville, GA
Posts: 2,331
Total Cats: 202
Default

Makes sense. I didn't catch the SSR = Solid State Relay when I first read it. I am pretty sure it was talked about earlier in the thread but it's been awhile since I spent serious time reading through it.
Chiburbian is offline  
Old 12-07-2016, 05:41 PM
  #342  
Former Vendor
Thread Starter
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

Aidan, why did you wire your relay ground to the OEM fuel pump ground instead of straight back to the battery? Convenience or concern about ground loops or something else?
Savington is offline  
Old 12-07-2016, 05:43 PM
  #343  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

probably convenience...I know I have 2 big wires running to the trunk.

let me go back and look at my pictures.

Edit: Yeah it was convenience. I think either one should work though.

You just need to provide a reference that the ECU ground gets "compared" against.

The transistor turns on when the voltage difference between the fuel pump signal and relay ground is smaller than a certain voltage.

ECU and battery ground should be very similar, if I were to do it again I might use the battery ground for the relay ground.

Last edited by aidandj; 12-07-2016 at 05:54 PM.
aidandj is offline  
Old 12-07-2016, 06:13 PM
  #344  
Former Vendor
Thread Starter
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

Cool, thank you for the help.

Off to grab a 1N4001 and some 8AWG wire. 8 gauge will give me some headroom to upgrade to a Walbro 450 later on if I need to. Planning to feed the DW300 ~13.5A at full boost, but a Walbro 450 would need ~19A at the same pressure.
Savington is offline  
Old 12-07-2016, 06:14 PM
  #345  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

8AWG. Damn, just gotta one up me.

I'm running that 450 you sold me on 10AWG wire. I think I did math at some point. And 10AWG was overkill for me.

http://www.calculator.net/voltage-dr...s=20&x=55&y=15

Cool calculator. ~4ft of wire. .20 voltage drop at 20Amps on 10AWG. .16 with 8AWG.
aidandj is offline  
Old 12-07-2016, 06:24 PM
  #346  
Former Vendor
Thread Starter
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

I used a different calculator and I think it was a little too conservative. 10 will be fine.
Savington is offline  
Old 12-07-2016, 06:26 PM
  #347  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

Are you running the stock fuel pump connector? Or something else.

At a possible 18-20 amps I wasn't going to risk the stock wiring. Not without a full fire system at least.
aidandj is offline  
Old 12-07-2016, 06:44 PM
  #348  
Former Vendor
Thread Starter
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

Stock connector. Punch the numbers into your calculator - the pessimist in me says they're 18awg wires, but it's only 6 inches of wire. At 20A, the voltage drop is actually lower than pulling the 20A down 4ft of 10awg.
Savington is offline  
Old 12-07-2016, 06:45 PM
  #349  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

I'm scared of fire not voltage.

I also severely over think things. Almost as bad as @EO2K but nobody gets on his level.
aidandj is offline  
Old 12-07-2016, 06:47 PM
  #350  
Elite Member
iTrader: (1)
 
sonofthehill's Avatar
 
Join Date: Apr 2014
Location: SF Bay Area, CA
Posts: 3,074
Total Cats: 551
Default

sonofthehill is offline  
Old 12-07-2016, 06:51 PM
  #351  
Elite Member
iTrader: (37)
 
EO2K's Avatar
 
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Default

EO2K is offline  
Old 12-07-2016, 06:58 PM
  #352  
afm
Senior Member
iTrader: (3)
 
afm's Avatar
 
Join Date: Nov 2015
Location: Berkeley, CA
Posts: 981
Total Cats: 508
Default

@EO2K uses shielded wiring for his fuel pump
afm is offline  
Old 12-07-2016, 07:00 PM
  #353  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

Originally Posted by afm
@EO2K uses shielded wiring for his fuel pump


lost it.
aidandj is offline  
Old 12-07-2016, 07:13 PM
  #354  
Elite Member
iTrader: (37)
 
EO2K's Avatar
 
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Default

Gotta keep the pump noise out of the stereo, right?

EO2K is offline  
Old 12-07-2016, 07:48 PM
  #355  
Former Vendor
Thread Starter
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

The stock wires are 16awg, same as what's inside the tank.

Bulkhead Fuel Pump Harness Assemblies

I would do this, which is 10awg outside and 16awg inside, but....it's still 16awg inside. What's the difference between 16awg inside the tank, and 16awg inside the tank + 4" of it outside the tank?
Savington is offline  
Old 12-07-2016, 07:53 PM
  #356  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

I used a 4 pin bulkhead. 2 pins for power, 2 for ground. Stock bulkhead for level sender.
aidandj is offline  
Old 12-07-2016, 08:00 PM
  #357  
Elite Member
 
codrus's Avatar
 
Join Date: Mar 2007
Location: Santa Clara, CA
Posts: 5,165
Total Cats: 855
Default

Originally Posted by aidandj
I used a 4 pin bulkhead. 2 pins for power, 2 for ground. Stock bulkhead for level sender.
Link?

--Ian
codrus is offline  
Old 12-07-2016, 08:02 PM
  #358  
Elite Member
iTrader: (37)
 
EO2K's Avatar
 
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Default

You probably don't want it. Its the one from Racetronix that he and Leafy were endlessly complaining about.

The Radium one actually looks better, but its significantly more expensive.
EO2K is offline  
Old 12-07-2016, 08:17 PM
  #359  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

I'm going to have a mod delete that link. It sucked. Overpriced garbage.

Leafy seems to think the GM specific model would work in ours but i disagree.
aidandj is offline  
Old 12-07-2016, 08:26 PM
  #360  
Former Vendor
Thread Starter
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,099
Default

Looking closer at the Radium part, it's actually four 16awg wires inside the tank and two 10awg outside, so that's definitely an upgrade over stock. Having said that, I don't think it will fit under the stock fuel tank cover.
Savington is offline  


Quick Reply: Trackspeed's '02SE "Acamas" - EFR6758, TSE motor, 500whp or bust



All times are GMT -4. The time now is 06:21 PM.