DIY Turbo Discussion greddy on a 1.8? homebrew kit?

Protecting heater lines from DP

Thread Tools
 
Search this Thread
 
Old 05-10-2009, 01:23 PM
  #1  
Elite Member
Thread Starter
iTrader: (7)
 
SKMetalworks's Avatar
 
Join Date: Jan 2007
Location: Renton Washington
Posts: 1,731
Total Cats: 4
Default Protecting heater lines from DP

I have done some "googling" and now i have more questions than before. The problem is that my downpipe is in contact with my heater lines. I know that the DP is gonna get hot and melt them. What would be the best (affordable) effective solution to this. I have seen the header "wrap" stuff but not sure if that would keep the heat from melting my lines.
Alloy heat shield
was also looking at that but still would like a "professional" opinion.

Thanks
SKMetalworks is offline  
Old 05-10-2009, 01:58 PM
  #2  
Junior Member
iTrader: (1)
 
1redcanuck's Avatar
 
Join Date: Jul 2007
Posts: 123
Total Cats: 0
Default

This is what I used.

Thermo Tec 14000 - Thermo-Tec Thermo Shield Aluminized Wrap
1redcanuck is offline  
Old 05-10-2009, 02:05 PM
  #3  
Elite Member
Thread Starter
iTrader: (7)
 
SKMetalworks's Avatar
 
Join Date: Jan 2007
Location: Renton Washington
Posts: 1,731
Total Cats: 4
Default

Perfect! ordering right now
SKMetalworks is offline  
Old 05-10-2009, 02:19 PM
  #4  
Junior Member
iTrader: (1)
 
1redcanuck's Avatar
 
Join Date: Jul 2007
Posts: 123
Total Cats: 0
Default

Also you can pry/bend the heater hose as far toward the firewall as possible.
1redcanuck is offline  
Old 05-10-2009, 02:52 PM
  #5  
Elite Member
iTrader: (8)
 
wayne_curr's Avatar
 
Join Date: Aug 2007
Location: Bellingham, Wa
Posts: 2,712
Total Cats: 4
Default

Originally Posted by 1redcanuck
Also you can pry/bend the heater hose as far toward the firewall as possible.
Exactly. I used the top half of my jack handle on the heater pipe and just bent it as far as I could get it. For the wrap I got some reflective fiberglass wrap, prolly exactly like whats in the link above. I didn't click it.

I still want a heat shield though...
wayne_curr is offline  
Old 05-10-2009, 03:49 PM
  #6  
Elite Member
 
Laur3ns's Avatar
 
Join Date: Mar 2008
Location: Enschede, NL
Posts: 2,053
Total Cats: 12
Default

Shielding is useless if they touch. They must not touch. Then you always need to wrap them.
Laur3ns is offline  
Old 05-10-2009, 04:23 PM
  #7  
Elite Member
iTrader: (15)
 
ZX-Tex's Avatar
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,847
Total Cats: 27
Default

I am using exhaust wrap on my heater lines. One has a thin stainless shield on top of the wrap for abrasion protection since it is in direct contact with the header bung for the EGR. So far so good.
ZX-Tex is offline  
Old 05-10-2009, 04:50 PM
  #8  
Elite Member
Thread Starter
iTrader: (7)
 
SKMetalworks's Avatar
 
Join Date: Jan 2007
Location: Renton Washington
Posts: 1,731
Total Cats: 4
Default

Originally Posted by wayne_curr
Exactly. I used the top half of my jack handle on the heater pipe and just bent it as far as I could get it. For the wrap I got some reflective fiberglass wrap, prolly exactly like whats in the link above. I didn't click it.

I still want a heat shield though...
Good idea. Im doing my exhaust build right now (still...) ill get that out of the way. I wish i known that when i did my SG pipe. Probably could of ran in longer and eased it back into the flow
SKMetalworks is offline  
Old 05-11-2009, 02:40 AM
  #9  
Elite Member
Thread Starter
iTrader: (7)
 
SKMetalworks's Avatar
 
Join Date: Jan 2007
Location: Renton Washington
Posts: 1,731
Total Cats: 4
Default

So after deciding to use the jack pump as a lever to use to move the heater lines i slipped and banged the **** out of my elbow. The whole left side of my hand was numb for an hour. Just got back from the ER and i had a contusion. AND i got 2 days off!! Thanks wayne for the sweet idea. I get to finish my exhaust. With the pain meds they gave me i should be able to
SKMetalworks is offline  
Old 05-11-2009, 03:19 PM
  #10  
Elite Member
iTrader: (8)
 
wayne_curr's Avatar
 
Join Date: Aug 2007
Location: Bellingham, Wa
Posts: 2,712
Total Cats: 4
Default

wow lol. No idea how you managed that. My jack handle has a huge inner diameter so the heater pipe went inside and there was no way for it to slip off.

Isn't a contusion just a bruise?
wayne_curr is offline  
Old 05-11-2009, 04:03 PM
  #11  
Elite Member
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default

Originally Posted by 1redcanuck
^ that.

and fiberglass weave from wirecare.com. Thats what I did
Saml01 is offline  
Old 05-11-2009, 04:17 PM
  #12  
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Chicago. (The less-murder part.)
Posts: 33,020
Total Cats: 6,588
Default

This business of bending the heater lines kinda scares me...

I simply cut the hoses which go to the heater core as short as possible, so that they are pulled back away from the downpipe.

And they're covered in the same sleeve. Good stuff. Used it on my neighbor's KTM as well, which had a clear PVC hose running right next to the exhaust header. Worked a treat.
Joe Perez is offline  
Old 05-11-2009, 05:01 PM
  #13  
Senior Member
 
Miatamaniac92's Avatar
 
Join Date: Nov 2005
Location: Austin, TX yall
Posts: 846
Total Cats: 0
Default

Safety wire can also be used to pull the insulated line away from the DP.

Chris
Miatamaniac92 is offline  
Old 05-11-2009, 05:07 PM
  #14  
Elite Member
iTrader: (4)
 
hornetball's Avatar
 
Join Date: Mar 2008
Location: Granbury, TX
Posts: 6,301
Total Cats: 696
Default

Not sure of your geometry, but you might also consider transitioning to beaded hard lines in the vicinity of the downpipe. The hard lines will have a greatly reduced outer diameter for the same inner diameter.
hornetball is offline  
Old 05-11-2009, 05:23 PM
  #15  
Miotta FTW!
iTrader: (24)
 
Splitime's Avatar
 
Join Date: Jun 2006
Location: Chicagoland, IL
Posts: 4,290
Total Cats: 31
Default

I got cheap domestic car alternator heat shielding and cut it to size, then wire wrapped mine. Held up so far.
Splitime is offline  
Old 05-11-2009, 05:36 PM
  #16  
Senior Member
 
Prospero's Avatar
 
Join Date: Nov 2007
Location: somewhere in NoVA
Posts: 533
Total Cats: -1
Default

Originally Posted by wayne_curr
wow lol. No idea how you managed that. My jack handle has a huge inner diameter so the heater pipe went inside and there was no way for it to slip off.

Isn't a contusion just a bruise?
Contusion is a "deep tissue bruise" with swelling and longer lasting pain and suffering. Had contusions on both arms after my accident... feels like a harsh workout soreness with much more tenderness.

Oh as far as the heat shielding:

HSP270200 - Reflect-A-Sleeve Reflective Hose & Wire Covering - 2" I.D X 3' Long - Solid Sewn Seam

Part#: HSP270200

Manufacturer Part#: 270200

(Qty: 1 x $22.02)



HSP203123 - Colored Sleeving - 25' Roll, Adjustable Inside Diameter:1/4" To 7/16" - Withstands 1200 Degrees F Continuous - Yellow

Part#: HSP203123

Manufacturer Part#: 203123

(Qty: 1 x $18.60)



HSP350008 - Thermal-Tie Stainless Steel "Zip Ties" - For Fastening Heat Wrap Etc. 8" Long, 8 Pieces

Part#: HSP350008

Manufacturer Part#: 350008

(Qty: 1 x $13.96)

Heatshield Products - Thermal and heat protective sleeving

I have been using this for my cars with no issues at all.

Cheers,
Prospero
Prospero is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Full_Tilt_Boogie
Build Threads
84
04-12-2021 04:21 PM
bigmackloud
Miata parts for sale/trade
19
01-08-2021 11:24 AM
StratoBlue1109
Miata parts for sale/trade
21
09-30-2018 01:09 PM
JesseTheNoob
DIY Turbo Discussion
15
09-30-2015 02:44 PM



Quick Reply: Protecting heater lines from DP



All times are GMT -4. The time now is 09:14 AM.