Closed mode conflict b/c of larger injectors?
Did some diagnosis on the 99 with EMU this weekend....confirmed that rear o2 is putting out a signal. When the car warms up, and goes into closed mode at idle [I think], the idle becomes terrible. I end up throwing misfire codes, like P0302.
Clear the code, cool the car off - idles beautifully. This car has 440 injectors and a MAP to run the EMU. I have also relocated the IAT to the exit of the intercooler. The ECU still uses the MAF for its functions. I am not versed enough in EMU to understand where to move next... The goal will be to get through the O2 sensor check and finally get emissions tested, but I cannot do that if I am continuously throw P03xx codes due to what I guess is an over-rich idle condition after closed mode starts. How do I get the EMU to take over the function in this case? Or how do I get the ECU to recognize the larger injectors. How do I get the ECU and EMU to handoff to each other correctly? PS - EGR tube not available, bu GA allows 2 unfilled readiness checks, so I think I can live with that, as I think EGR is the last test in the readiness cycle. Thanks in advance for any advice. |
Quick update - earlier, I got a hint from sturovo to check if the O2 was shunted to the EMU. Just one is - signal from the front O2. This is being run into the analog voltage input and back out of the analog voltage output. Also - the sensor ground send to / from the EMU, but that is needed for the injectors.
For my next move, I will look into the menus of EMU, and likely break and short the connection back to the ECU. |