Tons are using a hosebarb and clamp on the oil return line, probably 80% or more of us anyway.
The difference is the oil return isn't pressurized. It is merely a tube for the oil to drain via gravity back into the pan. |
Should I admit that even my drain line is braided S/S with AN fittings? Nah. :inout:
|
Originally Posted by Joe Perez
(Post 182000)
Should I admit that even my drain line is braided S/S with AN fittings? Nah. :inout:
I don't want to deal with possible line failures on the track. |
Originally Posted by Joe Perez
(Post 182000)
Should I admit that I shit gold? Nah. :inout:
|
Two feet of -8AN hose: $12
One straight NPT end: $8 One 90° -8AN end: $15 Turbo drain flange: $14 Never having to worry about the drain line again: Priceless. There are some things in life Savington can't afford. For everything else, there's money. :bigtu: |
this looks to good to be true (i would also get the flyinmiata oil thermostat kit to go with it) what do you guys think?
http://www.glowshiftdirect.com/index...ROD&ProdID=274 i'm looking to get the FM thermostat high temp lines AN fittings and a mocal cooler ~$300 |
Originally Posted by ldp82
(Post 182060)
this looks to good to be true (i would also get the flyinmiata oil thermostat kit to go with it) what do you guys think?
http://www.glowshiftdirect.com/index...ROD&ProdID=274 i'm looking to get the FM thermostat high temp lines AN fittings and a mocal cooler ~$300 |
I looked around at the Cooltek kit and at some Ebay stuff. In the end, I decided that a few extra bucks was worth it in such a critical system. Especially, since I just spent a ton on the BEGI S5 system. So, I ended up with this Mocal kit from BatInc: http://64.202.180.37/files/coolkit.pdf
I got Option 4 ($189) with the 16 row cooler ($126.75). $315.75 total is not bad for one of the best out there. I've seen the lower quality kits for more (like this one http://www.miatamania.com/Shop/ViewP...eIndexID=60192 for example). Simply decided not to go cheap. That's not always my philosophy. I did go with Megasquirt because I could not discover a reasonable advantage worth the extra $1500 for, say a Hydra. |
My pneumatic supply store guy today said that Aeroequp hose and push-lock fittings are good to 250psi without hoseclamps. I'm installing tomorrow.
Push-lock fittings are EXPENSIVE. :( I'm into the lines and fittings for nearly $70, so it might have been cheaper for them to custom-make me some -10AN lines. What's the line itself run these days? |
Originally Posted by magnamx-5
(Post 181953)
I simply refuse to use barded lines on anything other than fuel or water.
-t.t. |
Hooked up my cooler today. Push-locks are working great. We'll see what it does tomorrow at the track.
|
Originally Posted by jayc72
(Post 181970)
How many are using a hosebarb and clamp on their oil return line?
|
All times are GMT -4. The time now is 12:28 AM. |
© 2024 MH Sub I, LLC dba Internet Brands