General Miata Chat A place to talk about anything Miata

Fuel Pump Voltage Drop vs Pressure 1999

Thread Tools
 
Search this Thread
 
Old 03-16-2015, 03:13 AM
  #1  
Elite Member
Thread Starter
iTrader: (16)
 
patsmx5's Avatar
 
Join Date: Aug 2007
Location: Houston, TX
Posts: 9,292
Total Cats: 475
Default Fuel Pump Voltage Drop vs Pressure 1999

Did this test today, results below. I measured the voltage drop on each wire. Looks like the wires are too skimpy for my 255HP.

Attached Thumbnails Fuel Pump Voltage Drop vs Pressure 1999-fuel%2520pressure%2520drop_zpsveg0kfwf.jpg  
patsmx5 is offline  
Old 03-16-2015, 08:38 AM
  #2  
Tweaking Enginerd
iTrader: (2)
 
Ted75zcar's Avatar
 
Join Date: Mar 2013
Location: Boulder, CO
Posts: 1,770
Total Cats: 351
Default

Hmm, a current measurement would be useful. I was already planning on installing a circuit that regulates the FP voltage at the pump. A 1V drop across a wire is significant for DC.

Just ask Edison!
Ted75zcar is online now  
Old 03-16-2015, 09:20 AM
  #3  
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Chicago. (The less-murder part.)
Posts: 33,019
Total Cats: 6,587
Default

I'd be really curious to know how much of that 1v drop on the supply side is occurring across the fuel pump relay itself. As Ted75zcar noted, 1v drop on a 12v supply is massive, especially for something as nominally trivial as a fuel pump motor.

Do you have access to a DC ammeter capable of reading several amps?
Joe Perez is offline  
Old 03-16-2015, 10:03 AM
  #4  
Retired Mech Design Engr
iTrader: (3)
 
DNMakinson's Avatar
 
Join Date: Jan 2013
Location: Seneca, SC
Posts: 5,009
Total Cats: 856
Default

I suppose, since you made the measurements, it is likely that you are planning to jack the pressure up. If not:

The stock FPR is set at 60 psi, so that is where the operating point of the pump is. Flow goes either into engine, or back into tank. Very nearly a steady state proposition from the pump and wiring point of view.
DNMakinson is offline  
Old 03-16-2015, 11:34 AM
  #5  
Elite Member
Thread Starter
iTrader: (16)
 
patsmx5's Avatar
 
Join Date: Aug 2007
Location: Houston, TX
Posts: 9,292
Total Cats: 475
Default

Originally Posted by Joe Perez
I'd be really curious to know how much of that 1v drop on the supply side is occurring across the fuel pump relay itself. As Ted75zcar noted, 1v drop on a 12v supply is massive, especially for something as nominally trivial as a fuel pump motor.

Do you have access to a DC ammeter capable of reading several amps?
I have a meter that will got to 10A.

Looks like relay is under the dash.... Not sure I want to go digging for it to measure voltage drop across it.

Just checked walbro specs though

60 PSI = 10A current
90 PSI = 12A current.

I think the fuel/pump has 16 gauge wire going to it.

This calculator: American Wire Gauge table and AWG Electrical Current Load Limits with skin depth frequencies and wire breaking strength

Shows, with 12 ft of wire, at 12V

10A =1 V drop
12A = 1.2V drop

So not that far off.
patsmx5 is offline  
Old 03-16-2015, 11:25 PM
  #6  
Tweaking Enginerd
iTrader: (2)
 
Ted75zcar's Avatar
 
Join Date: Mar 2013
Location: Boulder, CO
Posts: 1,770
Total Cats: 351
Default

Well, I guess the numbers add up then.

Just more incentive to build a high-current input spanning switch mode converter. The non-linearity that is tolerated in automotive electrical systems just baffles me.

I imagine you are probably going to install a higher gauge feed. I think if I was going that route I would probably drive a secondary relay at the pump using the existing control signal. That way you can wire directly from the battery with the larger conductor, but you don't have to run it back and forth.

I suspect this is discussed at length somewhere around here.

Dig the SC build by the way, I am in the process of piecing together my own compound ... even though everybody tells me not to do it
Ted75zcar is online now  
Old 03-17-2015, 08:36 AM
  #7  
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Chicago. (The less-murder part.)
Posts: 33,019
Total Cats: 6,587
Default

Originally Posted by Ted75zcar
The non-linearity that is tolerated in automotive electrical systems just baffles me.
Many years ago, there was a movement within the industry to transition to a 42v electrical system for this exact reason. Interest in the concept died out when the automakers started assuming that within 10-20 years we'd all be driving EVs with much higher-voltage electrical systems and the point would be moot.


Here we are in the 21st century, and our few EVs still have 12v electrical systems to drive all their conventional accessories.
Joe Perez is offline  
Old 03-17-2015, 12:51 PM
  #8  
Elite Member
Thread Starter
iTrader: (16)
 
patsmx5's Avatar
 
Join Date: Aug 2007
Location: Houston, TX
Posts: 9,292
Total Cats: 475
Default

Originally Posted by Ted75zcar
Well, I guess the numbers add up then.

Just more incentive to build a high-current input spanning switch mode converter. The non-linearity that is tolerated in automotive electrical systems just baffles me.

I imagine you are probably going to install a higher gauge feed. I think if I was going that route I would probably drive a secondary relay at the pump using the existing control signal. That way you can wire directly from the battery with the larger conductor, but you don't have to run it back and forth.

I suspect this is discussed at length somewhere around here.

Dig the SC build by the way, I am in the process of piecing together my own compound ... even though everybody tells me not to do it
Yes sir, that's the plan. Just going to add a relay near the battery area, and have it trigger off the old F/P wire. And thanks! I tested the oil pump flow rate on my engine last night, so getting close! (unintentional test btw)
patsmx5 is offline  
Old 02-03-2016, 02:18 PM
  #9  
Senior Member
iTrader: (5)
 
90civichhb's Avatar
 
Join Date: Oct 2014
Posts: 542
Total Cats: 36
Default

Sorry for the necro revive but what ever came of this? I feel like my car has some serious voltage drop during certain situations. I can hear the Walbro 255 change pitch with my turn indicaters. It's even more pronounced when the headlights and/or fan is running.
90civichhb is offline  
Old 02-03-2016, 04:36 PM
  #10  
Elite Member
Thread Starter
iTrader: (16)
 
patsmx5's Avatar
 
Join Date: Aug 2007
Location: Houston, TX
Posts: 9,292
Total Cats: 475
Default

Originally Posted by 90civichhb
Sorry for the necro revive but what ever came of this? I feel like my car has some serious voltage drop during certain situations. I can hear the Walbro 255 change pitch with my turn indicaters. It's even more pronounced when the headlights and/or fan is running.
I ran a 40A fuse to the battery, 10 gauge wire, 50A relay, and 10 gauge wires into the tank. 10 Gauge ground to chassis just outside of tank on the shelf. Voltage drop of 0.02-0.03 with twin walbro 255's. I now have a Walbro 450 and a Walbro 255, didn't measure it again but it's negligible with the new wiring.
patsmx5 is offline  
Old 02-03-2016, 04:57 PM
  #11  
Elite Member
iTrader: (3)
 
deezums's Avatar
 
Join Date: May 2014
Location: Kansas
Posts: 3,146
Total Cats: 201
Default

How did you get 10 gauge into the tank? I need to do this soon...
deezums is offline  
Old 02-03-2016, 06:10 PM
  #12  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

I'm using the racetronix adapter thingy. Got it on sale over black friday.

Racetronix - Universal Bulkhead Wiring System, 4-Way
aidandj is offline  
Old 02-03-2016, 06:15 PM
  #13  
Elite Member
iTrader: (3)
 
deezums's Avatar
 
Join Date: May 2014
Location: Kansas
Posts: 3,146
Total Cats: 201
Default

Not big enough for me, walbro 450 pulls 20A or more at high pressure and wants ~16A at 5 bar.



Well, I guess I could double up. I only need one fuel pump...
Attached Thumbnails Fuel Pump Voltage Drop vs Pressure 1999-walbro-f90000267-400lph-flowrates-chart-650.jpg  
deezums is offline  
Old 02-03-2016, 06:17 PM
  #14  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

How is that not big enough.

2 14 gauge wires is equivalent to 1 11 gauge wire. Should work fine.
aidandj is offline  
Old 02-03-2016, 06:24 PM
  #15  
Elite Member
iTrader: (3)
 
deezums's Avatar
 
Join Date: May 2014
Location: Kansas
Posts: 3,146
Total Cats: 201
Default

If I double down it should be big enough is what I meant to say. I don't want to ground inside the tank, so 4 wires is plenty fo me.

Cheaper and easier than what I was planning on doing.
deezums is offline  
Old 02-03-2016, 06:26 PM
  #16  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

Thats what i was assuming you were going to do. 2 power 2 ground.

Pat where did you ground outside the tank?

You could even use the 2 stock wires too if you wanted all of the wires.

Make sure you get the racetronix e85 plug/install kit for the walbro450
aidandj is offline  
Old 02-03-2016, 06:55 PM
  #17  
Elite Member
Thread Starter
iTrader: (16)
 
patsmx5's Avatar
 
Join Date: Aug 2007
Location: Houston, TX
Posts: 9,292
Total Cats: 475
Default

Originally Posted by aidandj
Thats what i was assuming you were going to do. 2 power 2 ground.

Pat where did you ground outside the tank?

You could even use the 2 stock wires too if you wanted all of the wires.

Make sure you get the racetronix e85 plug/install kit for the walbro450
A 10mm bolt on the shelf back there close to the tank.
patsmx5 is offline  
Old 02-03-2016, 07:15 PM
  #18  
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Chicago. (The less-murder part.)
Posts: 33,019
Total Cats: 6,587
Default

Originally Posted by patsmx5
I ran a 40A fuse to the battery, 10 gauge wire, 50A relay, and 10 gauge wires into the tank.
I was about to say "40A? Jesus, why not just measure the actual current and then size accordingly, rather than build a bomb right behind the driver's seat?"

Then I saw the chart which deezums posted.

Holy ****. 21A at 13.5V is 280 watts, which is a pretty substantial heating element. Granted, not a lot of us are running 110 PSI on the fuel rail at all times, but that's still amazing. Put three 100w light bulbs next to each other on your desk and turn them on, then see how long you can hold your hand over them.

Then put that in your fuel tank.

Then add 60% (for the other pump).
Joe Perez is offline  
Old 02-03-2016, 07:20 PM
  #19  
Ben
Supporting Vendor
iTrader: (33)
 
Ben's Avatar
 
Join Date: Jul 2006
Location: atlanta-ish
Posts: 12,659
Total Cats: 134
Default

We've known since 1999 that the stock wiring is inadequate for the stock fuel pump -- How is this news in 2016?

For a 20A pump driven by the battery via relay, you'll want a minimum of 12ga wiring. If you were gangster, you'd use a spare PWM output to duty cycle that big *** fuel pump at low loads. Easy breezy with a solid state relay.
__________________
Chief of Floor Sweeping, DIYAutoTune.com & AMP EFI
Crew Chief, Car Owner & Least Valuable Driver, HongNorrthRacing

91 Turbo | 10AE Turbo | 01 Track Rat | #323 Mazda Champcar

Originally Posted by concealer404
Buy an MSPNP Pro, you'll feel better.
Ben is offline  
Old 02-03-2016, 07:21 PM
  #20  
Ben
Supporting Vendor
iTrader: (33)
 
Ben's Avatar
 
Join Date: Jul 2006
Location: atlanta-ish
Posts: 12,659
Total Cats: 134
Default

Originally Posted by Joe Perez
I was about to say "40A? Jesus, why not just measure the actual current and then size accordingly, rather than build a bomb right behind the driver's seat?"

Then I saw the chart which deezums posted.

Holy ****. 21A at 13.5V is 280 watts, which is a pretty substantial heating element. Granted, not a lot of us are running 110 PSI on the fuel rail at all times, but that's still amazing. Put three 100w light bulbs next to each other on your desk and turn them on, then see how long you can hold your hand over them.

Then put that in your fuel tank.

Then add 60% (for the other pump).
Which is why you PWM and/or stage your big fuel pump.
__________________
Chief of Floor Sweeping, DIYAutoTune.com & AMP EFI
Crew Chief, Car Owner & Least Valuable Driver, HongNorrthRacing

91 Turbo | 10AE Turbo | 01 Track Rat | #323 Mazda Champcar

Originally Posted by concealer404
Buy an MSPNP Pro, you'll feel better.
Ben is offline  