Delay AC
Is there a way to have megasquirt delay allowing the AC to run for the first 30 second after startup? Like when I remote start, i want the ac to be on but if it could wait 30 seconds that would be great. I have slightly rough idle for about 30 seconds and then all is good. I do have my ac wired to MS and I know I can set time there so AC doesn't rapidly off and on but that is for entire ride. I need a longer period just for startup.
Thanks |
The best answer would be to fix your idle after startup.
Nevertheless, what MS, running what FW? DNM |
I may have solved the issue by changing the ac delay to 5 seconds from 2. I have to do a few more start ups to know for sure.
I have a microsquirt. I suspect the latest firmware but i would have to check on that. |
What I was contemplating won’t work on MS2.
I hope your adjustment is a good fix. DNM |