Wideband AFR not matching DIYPNP AFR

Thread Tools
 
Search this Thread
 
Old 03-04-2013, 02:23 PM
  #1  
Junior Member
Thread Starter
iTrader: (1)
 
Halcyon's Avatar
 
Join Date: Dec 2006
Location: San Francisco, CA
Posts: 323
Total Cats: 2
Default Wideband AFR not matching DIYPNP AFR

Both items have good ground.
I called AEM and they told me for 31-4100 to input the following:
10.0 afr at 0.0V
19.98 afr at 4.99V

I took a video and the AFRs don't match.
It doesn't look like a delay either.
For example during the short video:
wideband vs laptop
15.2 vs 15.7
14.9 vs 15.5
14.5 vs 15.4
14.4 vs 15.0
14.2 vs 14.9
14.1 vs 14.7
14.2 vs 14.5
14.4 vs 14.7
14.7 vs 15.0
14.3 vs 15.1
14.3 vs 14.7

So it's not even a fixed pattern.
Any suggestions on what I can try?
Halcyon is offline  
Old 03-04-2013, 02:27 PM
  #2  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

you need to measure voltages to account for any groudning offset between the gauge and MS and account for that in the calibration, then if it's still not quite right...


you might need to change the lamdba lag factor? But keep in mind your MS will update the readings much faster that silly *** ugeo display will. it has awful refresh rates.
Braineack is offline  
Old 03-04-2013, 02:58 PM
  #3  
Junior Member
Thread Starter
iTrader: (1)
 
Halcyon's Avatar
 
Join Date: Dec 2006
Location: San Francisco, CA
Posts: 323
Total Cats: 2
Default

In general, what's a good lambda lag factor?
Halcyon is offline  
Old 03-04-2013, 03:07 PM
  #4  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

as high as possible (ie, no filtering/dampening).
Braineack is offline  
Old 03-04-2013, 03:11 PM
  #5  
Junior Member
Thread Starter
iTrader: (1)
 
Halcyon's Avatar
 
Join Date: Dec 2006
Location: San Francisco, CA
Posts: 323
Total Cats: 2
Default

To measure grounding offset. Do I do a voltage drop test?
Halcyon is offline  
Old 05-13-2013, 10:59 PM
  #6  
Junior Member
 
jbresee's Avatar
 
Join Date: Aug 2007
Location: Burlington, VT
Posts: 428
Total Cats: 1
Default

Halcyon,
did you figure this out?
I am seeing a similar issue with my AEM.
Jim
jbresee is offline  
Old 05-13-2013, 11:01 PM
  #7  
Elite Member
iTrader: (1)
 
Full_Tilt_Boogie's Avatar
 
Join Date: May 2009
Location: Jacksonville, FL
Posts: 5,155
Total Cats: 406
Default

Link your grounds.
Full_Tilt_Boogie is offline  
Old 05-14-2013, 08:06 AM
  #8  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

Originally Posted by jbresee
Halcyon,
did you figure this out?
I am seeing a similar issue with my AEM.
Jim
calibrate your MS to match the actual output of you gauge, not the published settings.
Braineack is offline  
Old 05-14-2013, 10:08 AM
  #9  
Junior Member
 
Fathom55's Avatar
 
Join Date: Mar 2013
Location: Houston
Posts: 107
Total Cats: -3
Default

Brain, is the assumption there that the gauge is right and the published settings become irrelevant once the grounding effects are factored in?
Fathom55 is offline  
Old 05-14-2013, 10:08 AM
  #10  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

si.
Braineack is offline  
Old 05-14-2013, 11:18 AM
  #11  
Junior Member
 
skinny's Avatar
 
Join Date: May 2011
Location: UK
Posts: 47
Total Cats: 0
Default

does the aem let you output set voltages?

on my LC-1 i got it to output from 0v to 5v in steps of 0.5v and recorded what it gave me in tunerstudio. as well as a linear voltage offset that increased with voltage, i had a very funny point at the top end that was throwing my 0-5v calibration out using those two points.



anyway, the upshot is, whatever afr (or volts) your tunerstudio reads for a given voltage output from your wideband, just set that afr as the setpoint for that voltage. in my case, 4.5v output gives 4.65v reading in TS... 4.65v = 19.33 AFR so set 19.33AFR to 4.5v in the wideband.

the check is to use the equation generated in the graph above to give you the offset for 14.7 AFR. For me, 2.265v output gives 2.35v reading in TS. Set output to 2.265v (an option whilst warming up on the LC-1) and check you get 14.7 AFR in TS.

however, if it's not a consistent relationship then you either need to work on your grounds or concentrate on the area from 11 - 18 AFR if that's any better.
Attached Thumbnails Wideband AFR not matching DIYPNP AFR-afrgraph_zps1ba27564.jpg  
skinny is offline  
Old 05-14-2013, 12:43 PM
  #12  
Elite Member
iTrader: (11)
 
miatauser884's Avatar
 
Join Date: Feb 2009
Posts: 2,959
Total Cats: 11
Default

I had to use the custom gauge for my AEM to match TS. The 4100 calibration was always about .15 to .2 off

iirc

0V = 10
5V = 18.7

I have a feeling that everyone may have a slightly different calibration due to grounding and wiring.
miatauser884 is offline  
Old 05-15-2013, 10:06 PM
  #13  
Junior Member
 
jbresee's Avatar
 
Join Date: Aug 2007
Location: Burlington, VT
Posts: 428
Total Cats: 1
Default

On AEM's site there is a post about this. They suggest disconnecting the sensor, turning the car on and seeing if the gauge and TS both show 14.7.

I did this test and they match perfectly. Once I plug the sensor in, the gauge shows 14.7, but TS shows 15.2.

Does this imply that it's an issue with ground differences, or a problem with the gauge/WB itself?

Is it possible that the increase in power consumption caused by the sensor being installed causes the delta?
jbresee is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Rick02R
WTB
3
01-03-2016 07:18 PM
The Gleas
MEGAsquirt
3
10-01-2015 09:30 AM
itsMikey
MSPNP
3
09-28-2015 06:40 AM



Quick Reply: Wideband AFR not matching DIYPNP AFR



All times are GMT -4. The time now is 07:39 AM.