Miata Turbo Forum - Boost cars, acquire cats.

Miata Turbo Forum - Boost cars, acquire cats. (https://www.miataturbo.net/)
-   MEGAsquirt (https://www.miataturbo.net/megasquirt-18/)
-   -   MAP behaves oddly during Overrun.. (https://www.miataturbo.net/megasquirt-18/map-behaves-oddly-during-overrun-19098/)

Joe Perez 04-01-2008 07:50 PM

MAP behaves oddly during Overrun..
 
1 Attachment(s)
I remember a little while ago some people mentioning that they sometimes observed MLV to populate very strange values into certain cells. I myself have seen this occur frequently in the 100kpa area, and I figured out why.

It seems that sometimes, but not always, while I am in overrun (coasting in gear) my MAP value jumps to exactly 100 kpa and stays there for a moment, then reverts back to reality. I have seen this not only in the logs, but also on the gauge display in Megatune. It's never done it while I'm on the throttle, and oddly it does not turn the fuel back on when it happens.

A full log is attached, but here's a screenshot of a typical event:

http://img132.imageshack.us/img132/250/graph2mm1.gif


Has anyone ever seen such a thing before?

The_Pipefather 04-01-2008 11:28 PM

You know, I am neither turbocharged, nor at sea level, yet I see this today:

http://img225.imageshack.us/img225/3489/graphsj4.png

cjernigan 04-02-2008 12:49 AM

I found 4 similar events.
http://i27.tinypic.com/4jhwx.png

http://i32.tinypic.com/2u8c503.png

http://i32.tinypic.com/2iscjtk.png

http://i28.tinypic.com/ohkbjo.png

Joe Perez 04-03-2008 11:54 AM

This morning I turned off Overrun and logged. The exact same thing happened- both in the log and on the gauge display. And again, it seemed not to impact the actual fueling- it's as though this is a display / logging artifact only.

Damned odd. I've started a thread over at MSExtra, which so far has failed to gather much interest. Seems that folks over there don't really care an awful lot about debugging... http://www.msextra.com/viewtopic.php?p=183865#183865

cjernigan 04-03-2008 11:56 AM


Originally Posted by Joe Perez (Post 237643)
This morning I turned off Overrun and logged. The exact same thing happened- both in the log and on the gauge display. And again, it seemed not to impact the actual fueling- it's as though this is a display / logging artifact only.

Damned odd. I've started a thread over at MSExtra, which so far has failed to gather much interest. Seems that folks over there don't really care an awful lot about debugging... http://www.msextra.com/viewtopic.php?p=183865#183865

I guess that is why RB26 has jumped up and helped start the DIY EFI project?

Matt Cramer 04-03-2008 12:27 PM

I haven't seen this behavior on our own tests, so I'd encourage the others who have to post their similar logs in Joe's thread on MSExtra.com. The more data the developers have, the more they'll have to go on.

cjernigan 04-03-2008 12:42 PM

I'll upload my data as well to msextra.

cjernigan 04-03-2008 05:28 PM

Hey guys.
In the meantime until we find a solution to this problem we can use a custom filter in MLV under the advanced options. Just click on "custom filter" and then enter this [MAP] = 100 && [TP] = 0
That will filter out all of the spikes where TP = 0 and MAP = 100. I just tried it out and it works great. Instead of it adding 20 extra VE in my 100 kpa row it made accurate adjustments.

The_Pipefather 04-03-2008 07:38 PM

Or if you dont have a TPS you can say [MAP]=100 and [O2]=4.99 too, isn't that right?

Joe Perez 04-04-2008 01:06 AM


Originally Posted by cjernigan (Post 237809)
In the meantime until we find a solution to this problem we can use a custom filter in MLV under the advanced options. Just click on "custom filter" and then enter this [MAP] = 100 && [TP] = 0

Genius! At least someone has been reading and paying attention. :bigtu: That works nicely.

Joe Perez 06-06-2008 10:55 AM

The problem has been properly solved by Keithg: http://www.msextra.com/viewtopic.php...187749#p187749

Short version: it's the kpafactor4250.inc file in the /mtCfg/ directory. The one which comes with MegaTune only has valid values down to 12 kPa, and considers anything below that to be a sensor error. The one which comes in the /hr10x/src/ directory (and is compiled into the bin) has valid data down to 10 kPa. So, every time the MAP voltage drops to ~.05v or less, even though the MS itself is able to interpret this properly, MT considers it an error and throws a 100.

Copy the version of the file that came with the hr distribution into /mtCfg/, and the problem is no more! :bigtu:

hustler 06-06-2008 10:58 AM

shoulda gone hydra, son.

y8s 06-06-2008 11:58 AM


Originally Posted by hustler (Post 267526)
shoulda gone hydra, son.

right because hydra would just say "sorry, we cannot fix your version of the software. do not run below 12kpa"


All times are GMT -4. The time now is 12:19 AM.