Old 02-26-2007, 11:14 PM
  #1  
Senior Member
Thread Starter
iTrader: (2)
 
adbradley's Avatar
 
Join Date: Feb 2006
Location: Mesa, AZ
Posts: 999
Total Cats: 0
Default ms grounds

ok i have the the 5 grounds 8,9,10, 11, and 19 all connected to one wire comming from the db37, what pin on the ecu should i connect this to??
adbradley is offline  
Old 02-26-2007, 11:26 PM
  #2  
Senior Member
 
Al Hounos's Avatar
 
Join Date: Oct 2005
Location: Knoxville
Posts: 1,168
Total Cats: 0
Default

stock ecu ground...
Al Hounos is offline  
Old 02-26-2007, 11:33 PM
  #3  
Senior Member
Thread Starter
iTrader: (2)
 
adbradley's Avatar
 
Join Date: Feb 2006
Location: Mesa, AZ
Posts: 999
Total Cats: 0
Default

whitch one, there are like 4?

2a, 2b, 2c, 2d
adbradley is offline  
Old 02-26-2007, 11:37 PM
  #4  
Junior Member
 
mschlang's Avatar
 
Join Date: Jun 2006
Location: LV, NV
Posts: 225
Total Cats: 0
Default

I ran the ground to the stock grounds on the engine near the CAS and FP regulator. You can never have too good of a ground connection.
mschlang is offline  
Old 02-27-2007, 07:57 AM
  #5  
Junior Member
 
ecugrad's Avatar
 
Join Date: Feb 2006
Location: Greenville, NC
Posts: 211
Total Cats: 0
Default

Originally Posted by mschlang
I ran the ground to the stock grounds on the engine near the CAS and FP regulator. You can never have too good of a ground connection.
I ran mine to roughly the same location.
ecugrad is offline  
Old 02-27-2007, 09:45 AM
  #6  
Senior Member
Thread Starter
iTrader: (2)
 
adbradley's Avatar
 
Join Date: Feb 2006
Location: Mesa, AZ
Posts: 999
Total Cats: 0
Default

so pin 8,9,10,11, and 19 on the ms connector can all connect to the ground near the engine??
adbradley is offline  
Old 02-27-2007, 02:10 PM
  #7  
Elite Member
iTrader: (3)
 
Arkmage's Avatar
 
Join Date: May 2006
Location: Houston, TX
Posts: 2,895
Total Cats: 0
Default

I grounded them to one of the stock ecu mounting bolts. Also, what gauge wire did you use for your ground? If you connect all of them together in the DB37 (I did) you need to make sure you have a low enough gauge wire to support all those grounds without noise interference.
Arkmage is offline  
Old 02-27-2007, 02:24 PM
  #8  
Elite Member
iTrader: (13)
 
cjernigan's Avatar
 
Join Date: Oct 2006
Location: Atlanta, GA
Posts: 8,091
Total Cats: 7
Default

What would you recommend than arkmage?
cjernigan is offline  
Old 02-27-2007, 02:26 PM
  #9  
Senior Member
Thread Starter
iTrader: (2)
 
adbradley's Avatar
 
Join Date: Feb 2006
Location: Mesa, AZ
Posts: 999
Total Cats: 0
Default

i used like a 10 gauge
adbradley is offline  
Old 02-27-2007, 05:19 PM
  #10  
Elite Member
iTrader: (3)
 
Arkmage's Avatar
 
Join Date: May 2006
Location: Houston, TX
Posts: 2,895
Total Cats: 0
Default

Originally Posted by cjernigan
What would you recommend than arkmage?
10-12 ga would be ideal... I wouldn't use anything higher than 14.
Arkmage is offline  
Old 02-27-2007, 05:45 PM
  #11  
Senior Member
Thread Starter
iTrader: (2)
 
adbradley's Avatar
 
Join Date: Feb 2006
Location: Mesa, AZ
Posts: 999
Total Cats: 0
Default

done
adbradley is offline  
Old 02-27-2007, 07:01 PM
  #12  
Newb
 
mazdasly75's Avatar
 
Join Date: Feb 2007
Location: Qc, Canada
Posts: 43
Total Cats: 0
Default

I always run the grounds to the battery to avoid spike into the inputs, but as long as there is less than 0.3 ohms in your connection, you are okay.

Last edited by mazdasly75; 03-01-2007 at 03:52 PM.
mazdasly75 is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Full_Tilt_Boogie
Build Threads
84
04-12-2021 04:21 PM
chris101
Miata parts for sale/trade
5
02-19-2016 07:13 PM
interestedofold
Suspension, Brakes, Drivetrain
5
09-29-2015 01:42 PM
btabor
ECUs and Tuning
10
09-28-2015 05:33 PM



Quick Reply: ms grounds



All times are GMT -4. The time now is 03:34 PM.