PLX wideband...settings?
Figure I better get this right, because the autotune will not work correctly unless I do. At idle, my wideband gauge is reading correctly, but in MT it's reading around 16.7afr. EGO settings must be off. Anyone else here using a PLX wideband and care to share the settings?
|
Think I may have found my answer, but still not sure why the readings in MT are incorrect.
http://www.plxdevices.com/products/w...utputGraph.jpg |
Check the voltage at the connection to the MS - what voltage is it reading at what AFR?
|
Make sure your PLX is grounded to the same spot as your MS.
|
Originally Posted by TrickerZ
(Post 390108)
Make sure your PLX is grounded to the same spot as your MS.
|
I always recommend this with Innovate units, and it would be a good idea to do it with a PLX as well: Ground the wideband directly to the block or to the cylinder head. Don't try grounding it to the chassis; that's just asking for ground offsets.
|