Possible PSA, MS3 Basic 9697 ac input pin
Just helped a buddy figure out a high idle issue on his 97, running MS Labs MS3 Basic. The AC was always being registered as ~on~. Turns out the tune had tableswitch mapped to the AC input pin, but digital in was the actual input that toggled with turning the AC on and off.
I don't have an MS3 Basic basemap, so I do not know if this is how it is there or not. v1.40FW |
"Datalog in" is the A/C input on the Basic MS3. Table switching is off by default but assigned to the "Tableswitch" input. Second hand unit?
|
Not sure if it is second hand or not. If your basemap has Datalog In assigned to AC In, my guess is that this unit had a DIY tune loaded at some point or something.
Not a big deal, My Google-Fu did not get me a MS3 Basic pin map for pins in the car harness, I was a little surprised by that. Maybe I didn't look hard enough. |