MEGAsquirt A place to collectively sort out this megasquirt gizmo

Running on 2 cyl under 40F COPS

Thread Tools
 
Search this Thread
 
Old 09-29-2009, 11:12 AM
  #1  
Senior Member
Thread Starter
iTrader: (8)
 
turbobluemiata's Avatar
 
Join Date: Aug 2006
Location: Springfield, IL
Posts: 1,012
Total Cats: 0
Default Running on 2 cyl under 40F COPS

Okay I searched and some other members are having this same problem. The car fires right up and runs on 2 cylinders. anytime its under 40F outside. once it warms up it runs perfect again. if its 45F outside no problems. what makes it not spark under 40F no one else's thread had a solution? It never did this before the COPS conversion.?
turbobluemiata is offline  
Old 09-29-2009, 11:14 AM
  #2  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

are you sure it's running on 2, or just running like ****?
Braineack is offline  
Old 09-29-2009, 03:54 PM
  #3  
Senior Member
Thread Starter
iTrader: (8)
 
turbobluemiata's Avatar
 
Join Date: Aug 2006
Location: Springfield, IL
Posts: 1,012
Total Cats: 0
Default

I'm sure its running on 2, its full lean and pure gas is pouring out the exhaust. I don't get it? being 45F is 100% different
turbobluemiata is offline  
Old 09-29-2009, 03:58 PM
  #4  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

your cold start settings tuned good?
Braineack is offline  
Old 09-29-2009, 04:00 PM
  #5  
Elite Member
iTrader: (8)
 
wayne_curr's Avatar
 
Join Date: Aug 2007
Location: Bellingham, Wa
Posts: 2,712
Total Cats: 4
Default

fouling plugs?
wayne_curr is offline  
Old 09-29-2009, 04:05 PM
  #6  
Senior Member
Thread Starter
iTrader: (8)
 
turbobluemiata's Avatar
 
Join Date: Aug 2006
Location: Springfield, IL
Posts: 1,012
Total Cats: 0
Default

i think the cold settings are tuned good it fires up good, just runs like poop and if its fouling plugs by starting then this sucks... I saw a thread a while ago about someone making a switch for COPS in the cold I dont remember what it was but I couldnt find it in search
turbobluemiata is offline  
Old 09-29-2009, 04:05 PM
  #7  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

post a log.
Braineack is offline  
Old 09-29-2009, 04:11 PM
  #8  
Senior Member
Thread Starter
iTrader: (8)
 
turbobluemiata's Avatar
 
Join Date: Aug 2006
Location: Springfield, IL
Posts: 1,012
Total Cats: 0
Default

Well tomorrow its supposed to be below 40 again in the morning so ill try then, but I wanna figure it out before winter is in full force
turbobluemiata is offline  
Old 09-29-2009, 04:25 PM
  #9  
Elite Member
iTrader: (8)
 
wayne_curr's Avatar
 
Join Date: Aug 2007
Location: Bellingham, Wa
Posts: 2,712
Total Cats: 4
Default

I'm gonna bet on fouling plugs. What are your cranking settings? I foul plugs and start on 2 cyls atleast once every 2 weeks, could be more often than that. Started happening with my 550s. Since doing Joe's spark out mod, its better, but not 100% solved.

Keep in mind that fuel atomizes better in cold weather as well. This could also be what is leading to your fouled plugs.
wayne_curr is offline  
Old 09-29-2009, 04:28 PM
  #10  
Senior Member
Thread Starter
iTrader: (8)
 
turbobluemiata's Avatar
 
Join Date: Aug 2006
Location: Springfield, IL
Posts: 1,012
Total Cats: 0
Default

yea Im building up the courage to do joes mod still... but good to know it helped but still someone made a switch/box last year that he said made cold start with cops flawless but I cant find the thread?
turbobluemiata is offline  
Old 09-29-2009, 05:20 PM
  #11  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,493
Total Cats: 4,080
Default

jeez i replaced my plugs once in the last like 2-3 years.
Braineack is offline  
Old 09-29-2009, 05:21 PM
  #12  
Elite Member
iTrader: (12)
 
neogenesis2004's Avatar
 
Join Date: Aug 2006
Posts: 4,413
Total Cats: 20
Default

I run adaptronic....my car runs on 4 cylinders.
neogenesis2004 is offline  
Old 09-30-2009, 05:27 PM
  #13  
Senior Member
iTrader: (5)
 
bcrx7's Avatar
 
Join Date: Jul 2005
Posts: 697
Total Cats: 53
Default

I have find out that the problem was the coils. Perhaps b/c of the different dwell, if one of the coils does not fire (which means two of them are not firing since it's not a true sequential COP). The cold somehow effect the ignitor in the toyota COP. I dropped in some new coils and that fixed the problem.
bcrx7 is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Full_Tilt_Boogie
Build Threads
84
04-12-2021 04:21 PM
90 Turbo
MEGAsquirt
19
10-19-2015 03:23 PM
The Gleas
MEGAsquirt
3
10-01-2015 09:30 AM
FrankB
Miata parts for sale/trade
6
09-30-2015 11:48 AM



Quick Reply: Running on 2 cyl under 40F COPS