v1.5 upgrade error on Rev MS3 Basic
I upgraded my Rev-built MS3 Basic from 1.4.1 to the new 1.5 firmware and applied the old settings using the TunerStudio tool. Afterwards I got an error saying "zeros set in baro, air density, or warmup. This won't work."
I went through the tune and verified I'm not using baro correction and my air density and warmup settings are the same as before the upgrade. I also Googled this error message and couldn't find anything. I went back to 1.4.1 and everything is working fine again. Has anybody else seen this error? Any ideas on how to correct it? https://cimg0.ibsrv.net/gimg/www.mia...37ba57a11c.jpg |
Where did you find the new firmware? I'm still on 1.3.4
|
New firmware versions are available at Megasquirt Downloads Firmware and Software - Megasquirt EFI.
|
Go here, Megasquirt Downloads Firmware and Software - Megasquirt EFI
The Ms Labs MS3 Basic uses the standard firmware. |
Thanks! I was somehow under the impression Reverent used custom firmware.
|
Originally Posted by Alternative
(Post 1389383)
Thanks! I was somehow under the impression Reverent used custom firmware.
|
you went from an old map, you need to update it to work with newer firmware. those tables it's referencing are in %s, but 100% = no enrichment. those tables USED to be 0 = no enrichment. just go back in and make sure there's no invalid numbers in those tables, even if unused.
|
Originally Posted by Braineack
(Post 1389434)
you went from an old map, you need to update it to work with newer firmware. those tables it's referencing are in %s, but 100% = no enrichment. those tables USED to be 0 = no enrichment. just go back in and make sure there's no invalid numbers in those tables, even if unused.
|
@Braineack, thanks for the pointer. I had to enable barometric correction, reset to 100% instead of 0%, and turn it back off. Everything's working great now.
|
All times are GMT -4. The time now is 09:57 PM. |