anyone else experience heat harden external wastegate hoses?

what is the consequence? [loss of WG control, over boost???]

which is the best cure - S/S braid or high temperature hoses?

TIA
Old Jun 25, 2012 | 12:25 AM
  #2  
thirdgen's Avatar
Slowest Progress Ever
iTrader: (26)
 
Joined: Oct 2007
Posts: 6,029
Total Cats: 304
From: The coal ridden hills of Pennsylvania
Default

I had it harden my rubber water cooling lines and cause them to crack several times...but I just replace them cause it cost's me like 99 cents.
Someday I'll redo them in braided stainless.
I have never had an issue with a wastegate hose though.
Old Jun 25, 2012 | 02:15 AM
  #3  
curly's Avatar
Cpt. Slow
iTrader: (25)
 
Joined: Oct 2005
Posts: 15,168
Total Cats: 1,393
From: Oregon City, OR
Default

I've wrapped my wastegate hose and VTA breather hose with insulation ripped off an old carpet set, then taped it up with reflective aluminum ducting tape. Works wonders and it was free!

I looked into replacing all that crap with SS line, the breather hose, wastegate hose, and water line. Now that I refuse to use anything but Aeroquip fittings, it's somewhere around $100 shipped, I'll wait for an obvious issue to arise before spending that much dough on a few small hoses.
Old Jun 25, 2012 | 09:14 AM
  #4  
fooger03's Avatar
Elite Member
iTrader: (2)
 
Joined: Jan 2009
Posts: 4,149
Total Cats: 230
From: Columbus, OH
Default

Solution to high heat on signal hoses? Silicone.
Old Jun 25, 2012 | 09:31 AM
  #5  
mighty mouse's Avatar
Senior Member
iTrader: (9)
 
Joined: Jun 2007
Posts: 1,013
Total Cats: 21
From: NH
Default

I switched mine over to SS braided hose. Not cheap, but I don't have to worry about it.
Old Jun 25, 2012 | 10:30 AM
  #6  
Faeflora's Avatar
Elite Member
iTrader: (2)
 
Joined: Jan 2007
Posts: 8,682
Total Cats: 130
From: Los Angeles, CA
Default

SS braid will need to be replaced someday too.

Consequenses is no boost control. All the boost. It is good for you.

Just wrap the bastard in some thing.
Old Jun 25, 2012 | 06:14 PM
  #7  
mx594m's Avatar
Thread Starter
Junior Member
iTrader: (1)
 
Joined: Dec 2010
Posts: 279
Total Cats: 3
From: Knoxville, TN
Default

ok all; gonna try HT silicone
Old Jun 26, 2012 | 08:15 PM
  #8  
fwMiata's Avatar
Junior Member
 
Joined: Jan 2005
Posts: 237
Total Cats: 1
From: Fort Worth, Texas
Default

just get some aluminum tubing and flare it to fit the correct fitting, IE tial uses a bango, so get a banjo to AN, AN flare the tube then run it away from the heat a little ways then use whatever hose. the air doesnt care what it is in as long as it doesn't leak..
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
stoves
Suspension, Brakes, Drivetrain
5
Apr 21, 2016 03:00 PM
tazswing
Race Prep
20
Oct 3, 2015 11:04 AM
Aroundcorner
Miata parts for sale/trade
2
Oct 1, 2015 03:20 PM
mx592
Suspension, Brakes, Drivetrain
1
Oct 1, 2015 12:45 AM




All times are GMT -4. The time now is 05:54 AM.