LC-1 Response and Autotune
1 Attachment(s)
I noticed my LC-1 response time is set to "instant" and AFR's are always bouncing. It's hard to tune by hand a single cell on the map since the AFR is constantly moving up and down with the exhaust pulses.
Attachment 204538 Maybe slowing down the response speed on the LC-1 can make autotune to work better. any thoughts? |
do you have it wired in via serial or analog?
|
Originally Posted by 18psi
(Post 434666)
do you have it wired in via serial or analog?
Does the serial output use the same setting as the analogs? |
HOw much is it bouncing? I would imagine at idle there might be some of that, but at 2000-3000 it should be steady within a +/-.1
|
+- 0.8 at idle, boost, cruise (very fast oscillation)
Maybe I'm the only one with this problem. I purchased a replacement v-band clamp for my downpipe to be sure that is not an exhaust leak. |
Originally Posted by ismael_pt
(Post 434697)
+- 0.8 at idle, boost, cruise (very fast oscillation)
Maybe I'm the only one with this problem. I purchased a replacement v-band clamp for my downpipe to be sure that is not an exhaust leak. |
... I've never had this before. I wonder whats different?? You could try setting the sampling back a little bit to average it, but you may sample it when its on the low side.
|
All times are GMT -4. The time now is 02:08 AM. |