MS3X A/C Control issues
1 Attachment(s)
I'm having issues getting the a/c settings to work as my brain understands them to. The compressor will continue to cycle on and off very quickly even though I have the "delay since last on" set to 20 seconds. I have the "A/C on" button wired it so the 12v signal passes though both pressure/cycling switches before going into the DATA LOG input. Will wiring it this way "reset" the internal clock due to it working the same as the A/C switch being turned off and on?
https://cimg9.ibsrv.net/gimg/www.mia...0471b67537.jpg https://cimg2.ibsrv.net/gimg/www.mia...02646b1be6.jpg |
2 Attachment(s)
I got 2 data logs of when it's happening but can't seem to find where to look for the A/C status. Any help is appreciated.
|
Found my problem, I couldn't read my own wiring diagram and had the pressure/cycling switches on the wrong wire. Here is how it was actually wired. I fixed the wiring to match the one in the original post. AC now works as it should.
https://cimg1.ibsrv.net/gimg/www.mia...acfef7c26d.jpg |
All times are GMT -4. The time now is 09:59 PM. |