Knock sensor ground

Thread Tools
 
Search this Thread
 
Old Jan 5, 2016 | 11:11 AM
  #1  
btabor's Avatar
Thread Starter
Senior Member
iTrader: (3)
 
Joined: Oct 2008
Posts: 610
Total Cats: 12
From: Indianapolis
Default Knock sensor ground

I'm installing a vvt motor in my na. Currently butchering the vvt engine harness, removing unnecessary wiring and splicing into the na chassis wiring. Should I take the knock sensor ground to the megasquirt analog ground or would the back of the head work well for a good ground?
Old Jan 5, 2016 | 11:22 AM
  #2  
psyber_0ptix's Avatar
Elite Member
iTrader: (4)
 
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
Default

I had mine grounded at the head and it was too noisy to use. I would say with megasquirt, you should locate a free sensor ground and just wire it to that. I'm going to explore shielding as well.
Old Jan 5, 2016 | 11:30 AM
  #3  
btabor's Avatar
Thread Starter
Senior Member
iTrader: (3)
 
Joined: Oct 2008
Posts: 610
Total Cats: 12
From: Indianapolis
Default

the original knock sensor wire is twice as thick as all the other ones. I think I will run the ground to the MS then and a stand alone shielded wire to the ms by itself.
In the MS instructions it says the DB 37 pin 2 should be used for the wideband and pin 3 is "analog ground", should I ground it to pin 3 then? the knock sensor signal should be analog
Old Jan 5, 2016 | 05:15 PM
  #4  
sparkybean's Avatar
Junior Member
 
Joined: Mar 2012
Posts: 110
Total Cats: 13
Default

I had my knock sensor grounded at the ECU end (ECU power ground), picked up a ton of alternator whine below 3krpm.

Its now grounded at the block side (ring terminal onto bolt), and is better. Still not perfect, but much better.



EDIT: Knock sensor always grounded at ecu, knock sensor SHIELD grounded at ecu, then moved to block. I has the stupid.

Last edited by sparkybean; Jan 6, 2016 at 04:49 PM.
Old Jan 5, 2016 | 07:30 PM
  #5  
gooflophaze's Avatar
Senior Member
 
Joined: May 2007
Posts: 997
Total Cats: 156
From: Atlanta
Default

On my MS3 I used the sensor ground on the ECU side. I also uses shielded cable that was grounded to the block.

Wire - 2 Core Shielded 20 Gauge - 10&#39 DIYAutoTune.com

My knock logs were pretty clean.
Old Jan 5, 2016 | 08:01 PM
  #6  
aidandj's Avatar
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

Originally Posted by btabor
the original knock sensor wire is twice as thick as all the other ones. I think I will run the ground to the MS then and a stand alone shielded wire to the ms by itself.
In the MS instructions it says the DB 37 pin 2 should be used for the wideband and pin 3 is "analog ground", should I ground it to pin 3 then? the knock sensor signal should be analog
Running 1 unshielded and one shielded ruins the point of running a shielded ground. You are still going to get noise in the unshielded ground.
Old Jan 5, 2016 | 09:33 PM
  #7  
Joe Perez's Avatar
Boost Pope
iTrader: (8)
 
Joined: Sep 2005
Posts: 34,382
Total Cats: 7,504
From: Chicago. (The less-murder part.)
Default

Broadly speaking:

Sensor ground should be located at the ECU itself for all analog sensors (pressure, temperature, airflow, EGO, etc.) Where external signal-conditioning electronics are used (as with many knock sensor installations), the sensor should be grounded at the conditioning circuit, which should in turn be grounded at the ECU.

Shields, where present, should be grounded at one end only, and at the end nearest likely sources of EMI/RFI which, for most purposes, is the engine block.


These are general rules, and not every install is the same. But this is how the "professionals" do it, whether the application is automotive, industrial, broadcast / recording, etc.
Old Jan 6, 2016 | 08:58 AM
  #8  
btabor's Avatar
Thread Starter
Senior Member
iTrader: (3)
 
Joined: Oct 2008
Posts: 610
Total Cats: 12
From: Indianapolis
Default

I ended up using a shielded 3 strand ( 1 signal, 1 ground and extra non insulated wire -may hook this one up to the block- ) and 4 strand shielded for the extra 2 injector wires and vvt signal. They all end in the DB37 at their respective pins.
I think this should work fairly well.
Old Jan 6, 2016 | 09:51 AM
  #9  
Joe Perez's Avatar
Boost Pope
iTrader: (8)
 
Joined: Sep 2005
Posts: 34,382
Total Cats: 7,504
From: Chicago. (The less-murder part.)
Default

Originally Posted by btabor
I ended up using a shielded 3 strand ( 1 signal, 1 ground and extra non insulated wire
Does the overall arrangement of the cable look like this?



If so, the "extra non insulated wire" is the drain wire, and it's electrically connected to the shield. This is how you ground the shield (at one end only) to provide a drain for any energy which the shield absorbs.
Attached Thumbnails Knock sensor ground-usb26153.jpg  
Old Jan 6, 2016 | 10:11 AM
  #10  
btabor's Avatar
Thread Starter
Senior Member
iTrader: (3)
 
Joined: Oct 2008
Posts: 610
Total Cats: 12
From: Indianapolis
Default

That's exactly how it looks plus tin foil around the cables. Since the shielded cable doesn't run all the way to the knock sensor itself but to the knock sensor plug, could I wire the shield to be grounded to the back of the head?
Old Jan 6, 2016 | 10:40 AM
  #11  
Joe Perez's Avatar
Boost Pope
iTrader: (8)
 
Joined: Sep 2005
Posts: 34,382
Total Cats: 7,504
From: Chicago. (The less-murder part.)
Default

Originally Posted by btabor
That's exactly how it looks plus tin foil around the cables.
Yeah, that particular photo was of Belden 9451, in which the foil is bonded to the jacket such that it breaks away when the jacket is stripped (makes prepping the cables easier.) It's there, you just can't see it.

This is Belden 8451, which lacks the foil bond, so you can see that the foil remains in place after the jacket is stripped:



Both cables function the same, it's just a matter of preference. Some old-timers prefer the original design where you have to trim the foil away manually, I like the newer stuff which takes care of itself.


949 Racing


Originally Posted by btabor
Since the shielded cable doesn't run all the way to the knock sensor itself but to the knock sensor plug, could I wire the shield to be grounded to the back of the head?
Yeah, you can bond the drain wire (the uninsulated wire that's in contact with the shield) to whatever point is convenient. In the OEM design, I believe it went to ground somewhere near the front of the intake manifold, but any spot on the engine will be fine.

Last edited by Joe Perez; Feb 21, 2016 at 01:48 PM.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
fjs0001
Engine Performance
10
Jan 6, 2016 05:30 PM
dcamp2
Miata parts for sale/trade
0
Jan 4, 2016 10:02 PM
btabor
Engine Performance
8
Jan 4, 2016 09:56 PM
Savington
Miata parts for sale/trade
2
Jan 4, 2016 08:41 PM
ihiryu
Engine Performance
19
Jan 4, 2016 06:56 PM




All times are GMT -4. The time now is 09:37 AM.