Help Radiator fans not working?

Old Jul 2, 2007 | 06:44 PM
  #1  
SMRACER's Avatar
Thread Starter
Junior Member
 
Joined: Mar 2007
Posts: 50
Total Cats: 0
From: Denver, CO
Default Help Radiator fans not working?

So on one of the hottest days of the year here (100 degrees) I find out that my radiator fans are not working. I have both the AC fan and the radiator fan wired together and neither of them turned on. Any suggestions on what to check. Is there a fuse somewhere for them? Thanks.
Old Jul 2, 2007 | 11:28 PM
  #2  
timhill78's Avatar
Junior Member
iTrader: (3)
 
Joined: Aug 2006
Posts: 241
Total Cats: 0
From: Oregon
Default

I have a 1.8 but I had to switch the temp sensor in the emu perameters to a honda one. Do a search in emanaged miatas.
Old Jul 3, 2007 | 08:04 AM
  #3  
Racer46's Avatar
Junior Member
 
Joined: Oct 2006
Posts: 125
Total Cats: 0
From: Orlando, FL
Default

Looking back on some of your other posts, you seem to have a '91. On top of the thermostat housing there is a plug that goes into the temp. sensor. Is the wire broken? If so fix the wire. If not unhook the plug and insert a paper clip into the plug, then touch it to ground, the lift ring makes a good ground, with the engine running. Do the fans come on now? If so replace the temp. sensor. If not time to troubleshoot the relay. I don’t have the book with me so I can’t help you with that right now but the above fixes the problem 90% of the time.
Old Jul 3, 2007 | 12:05 PM
  #4  
SMRACER's Avatar
Thread Starter
Junior Member
 
Joined: Mar 2007
Posts: 50
Total Cats: 0
From: Denver, CO
Default

Cool thanks guys. I pulled the plug like you suggested Pete and used the paperclip and the fans did not work. I replaced the relay and everything works fine now. Thanks.
Old Jul 3, 2007 | 01:28 PM
  #5  
Racer46's Avatar
Junior Member
 
Joined: Oct 2006
Posts: 125
Total Cats: 0
From: Orlando, FL
Default

Welcome to the 10% club. I read some place that the fan relay was 15 amps and the fans were 10 amps each. So if you have them wired together you're drawing 20 amps. A little more than the relay is designed for. On the other hand I know of people who have been running the fans together for years with no problems.

Glad I could be of help.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
StratoBlue1109
Miata parts for sale/trade
21
Sep 30, 2018 01:09 PM
tazswing
Race Prep
20
Oct 3, 2015 11:04 AM
lsc224
Miata parts for sale/trade
2
Oct 1, 2015 09:17 AM
shooterschmidty
Engine Performance
8
Sep 30, 2015 10:28 PM


Thread Tools
Search this Thread

All times are GMT -4. The time now is 08:41 PM.