ITT: Stupid People Doing Stupid MS Things to Old 'Merican Iron
#23
Uuughhh, I free'd up the fast idle linkage(was stuck and kinda rusty) and adjusted the choke to center and now the car just fast idles all the time and will die if I sit at stop lights in gear for too long. I'm over this ****. Going to order the TBI adapter plate and fuel pump and ****.
I'm thinking DIY MS2 unless someone can convince me otherwise.
I'm thinking DIY MS2 unless someone can convince me otherwise.
#25
So my summit order looks like this:
TRD-2210 TBI Adapter, 3-Bolt TBI to Square Bore Carbureted Manifold
ADO-219-607 Throttle Body Repair Kit (I'm not 100% sure this is the right kit, but it seems like it)
ATX-E8094 Fuel Pump - 17PSI and 50 GPH, should be fine without a regulator and includes mounting brackets and hose barbs
SUM-390561 Fuel Injection Hose Clamps
CEL-65152 Fuel Injection Hose
KNN-PF-1300 Fuel Filter (I'm only going to put one pre pump)
PRO-302-290 Fuel Pump Block-off Plate (I'm sure there are cheaper ones, but this one called out the it's compatible with the 390FE)
VPE-17193 P-Clamps for the fuel line
Given how fast summit is at shipping things, I'm sure I'll still be hemming and hawing about which MS to get by the time it all arrives.
#27
Elite Member
iTrader: (37)
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Ok, so my **** is going to get a little weird because I have a dual tank setup, but I want to run this by you "people" before I get too far down the rabbit hole.
This is a super generalized "flow" diagram of how the factory system is setup on my truck:
There is no regulator, and everything is gravity fed from the tanks in the rear all the way up to the engine mounted mechanical fuel pump. Simple as dirt, right?
(73 & 74 are "special" in that the dual tank models included a brass tank selector valve that is mounted to the floor next to the drivers seat. If one tank runs dry, you reach down and turn the handle to select the next tank.)
So with the TBI there is a pressure regulator mounted inside the TBI unit itself, right before the injectors, and there is a return line that I will need to add. Because I've got dual tanks this complicates things immensely. I can't just return to one tank because it then becomes a transfer pump, and eventually I'm going to overfill the tank with the return and start pumping fuel out the vapor vent in whatever tank I'm returning to. I don't have the mental bandwidth to remember to "use main tank first" or whatever. I really don't want to complicate my setup by adding 2 more ridiculously long fuel lines and another tank valve, so I've been having a think about this.
I've read "on the internet" (everything you read on the internet being true and all) that all you need to do is add a T on the suction side of the TBI pump and run your return line into the T. Because the engine is always using some amount of fuel, it shouldn't build any pressure in the return and you are good to go. This sounded too good to be true, so I started doing some reading. It turns out this may or may not be the way to do things, so I'm slightly nervous about setting it up this way.
After thinking about it for a while, I've come up with this:
Perhaps "accumulator" is the wrong word for this, but its what I stuck on the drawing. My main concern would be getting a bunch of air trapped in the "accumulator" and building pressure that would keep fuel from gravity feeding from the tanks. I could put an atmospheric vent in the "accumulator" that would allow it to vent, but it would need a check valve to prevent the pump from just sucking air. The line for that vent would have to go up higher than the highest point in the fuel system (lest it gravity drain) and due to the height of the engine, we are now talking a fuel line that runs up past the top of the hood. Plus this adds stupid complication that I don't want to deal with. Maybe the "accumulator" doesn't need a vent? Maybe it just needs to be purged of air occasionally?
I'm very curious to get some input on this from the brain trust.
This is a super generalized "flow" diagram of how the factory system is setup on my truck:
There is no regulator, and everything is gravity fed from the tanks in the rear all the way up to the engine mounted mechanical fuel pump. Simple as dirt, right?
(73 & 74 are "special" in that the dual tank models included a brass tank selector valve that is mounted to the floor next to the drivers seat. If one tank runs dry, you reach down and turn the handle to select the next tank.)
So with the TBI there is a pressure regulator mounted inside the TBI unit itself, right before the injectors, and there is a return line that I will need to add. Because I've got dual tanks this complicates things immensely. I can't just return to one tank because it then becomes a transfer pump, and eventually I'm going to overfill the tank with the return and start pumping fuel out the vapor vent in whatever tank I'm returning to. I don't have the mental bandwidth to remember to "use main tank first" or whatever. I really don't want to complicate my setup by adding 2 more ridiculously long fuel lines and another tank valve, so I've been having a think about this.
I've read "on the internet" (everything you read on the internet being true and all) that all you need to do is add a T on the suction side of the TBI pump and run your return line into the T. Because the engine is always using some amount of fuel, it shouldn't build any pressure in the return and you are good to go. This sounded too good to be true, so I started doing some reading. It turns out this may or may not be the way to do things, so I'm slightly nervous about setting it up this way.
After thinking about it for a while, I've come up with this:
Perhaps "accumulator" is the wrong word for this, but its what I stuck on the drawing. My main concern would be getting a bunch of air trapped in the "accumulator" and building pressure that would keep fuel from gravity feeding from the tanks. I could put an atmospheric vent in the "accumulator" that would allow it to vent, but it would need a check valve to prevent the pump from just sucking air. The line for that vent would have to go up higher than the highest point in the fuel system (lest it gravity drain) and due to the height of the engine, we are now talking a fuel line that runs up past the top of the hood. Plus this adds stupid complication that I don't want to deal with. Maybe the "accumulator" doesn't need a vent? Maybe it just needs to be purged of air occasionally?
I'm very curious to get some input on this from the brain trust.
#28
Elite Member
iTrader: (37)
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Also, before you all go batshit insane, I know Ford made a reservoir/tank switch assembly that they used on 1980's dual tank F250/F350s that would take care of this problem. The part number is F1UZ-9B263-B and unfortunately they are quite expensive new:
https://www.ebay.com/itm/Genuine-For...B/302173280449
And I've never seen a dual tank anything in the junkyard. Anecdotal evidence (again, the internet) also says they tend to be quite failure prone. It feels like a bad idea to design a system around a somewhat rare and possibly failure prone part. K.I.S.S. and all.
I'm unaware as to how other manufacturers do this, but I'm open to suggestions.
https://www.ebay.com/itm/Genuine-For...B/302173280449
And I've never seen a dual tank anything in the junkyard. Anecdotal evidence (again, the internet) also says they tend to be quite failure prone. It feels like a bad idea to design a system around a somewhat rare and possibly failure prone part. K.I.S.S. and all.
I'm unaware as to how other manufacturers do this, but I'm open to suggestions.
#32
Elite Member
iTrader: (37)
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Actually, while we are here, does @18psi want to tune these things? Fuel only, you'll have no control over the timing. Should be fun, right?
To me, the "accumulator" idea seems like the simplest solution. If you guys don't think it'll work, I'd love to hear why.
#36
Elite Member
iTrader: (37)
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
Yeah, we should probably figure this out. Any one have any input?
@Monk? @aidandj?
I'm a cheap bastard and feel like the MS1 would get the job done, but don't have a problem with an MS2. Again, it would be nice to share notes.
@sixshooter, were you going to come play with us too?
@Monk? @aidandj?
I'm a cheap bastard and feel like the MS1 would get the job done, but don't have a problem with an MS2. Again, it would be nice to share notes.
@sixshooter, were you going to come play with us too?
#38
Elite Member
iTrader: (37)
Join Date: Apr 2010
Location: Very NorCal
Posts: 10,441
Total Cats: 1,899
You posted your project and asked if you needed to start spending money on it. The answer is obviously yes, so I assumed you would be playing along?
If not its cool, I just didn't want to leave anyone out from the stupid TBI funtimes
If not its cool, I just didn't want to leave anyone out from the stupid TBI funtimes