DIYAutotune CAN-EGT Setup Error
Thread Starter
Junior Member
iTrader: (2)
Joined: Sep 2013
Posts: 266
Total Cats: 7
From: Pittsburgh PA
Is there a way to tell if you are actually communicating to the CAN device? I am trying to use DIY's CANEGT and all I get from the CANEGO is the "Default AFR value in case of error" that I program into it. It does not seem obvious to me if the problem is with the connection between the CAGEGT and the MS3, or between the CANEGT and the LC-2 I am trying to use.
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
The point of the "Default AFR value in case of error" is so that you tell where the error is coming from. If Tunerstudio is displaying that AFR then you know that it is communicating with the CANEGT just fine. The error is between the LC-2 and the CANEGT. Make sure you are using the right port on the LC-2
Also if you were able to set the default error AFR value then you are communicating with the CAN-EGT over CANBus
Also if you were able to set the default error AFR value then you are communicating with the CAN-EGT over CANBus