Notices
MEGAsquirt A place to collectively sort out this megasquirt gizmo

DIYAutotune CAN-EGT Setup Error

Thread Tools
 
Search this Thread
 
Old Jun 20, 2017 | 11:19 AM
  #1  
Davezorz's Avatar
Thread Starter
Junior Member
iTrader: (2)
 
Joined: Sep 2013
Posts: 266
Total Cats: 7
From: Pittsburgh PA
Default DIYAutotune CAN-EGT Setup Error

Is there a way to tell if you are actually communicating to the CAN device? I am trying to use DIY's CANEGT and all I get from the CANEGO is the "Default AFR value in case of error" that I program into it. It does not seem obvious to me if the problem is with the connection between the CAGEGT and the MS3, or between the CANEGT and the LC-2 I am trying to use.
Old Jun 20, 2017 | 11:45 AM
  #2  
aidandj's Avatar
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

The point of the "Default AFR value in case of error" is so that you tell where the error is coming from. If Tunerstudio is displaying that AFR then you know that it is communicating with the CANEGT just fine. The error is between the LC-2 and the CANEGT. Make sure you are using the right port on the LC-2

Also if you were able to set the default error AFR value then you are communicating with the CAN-EGT over CANBus
Old Jun 20, 2017 | 12:10 PM
  #3  
Davezorz's Avatar
Thread Starter
Junior Member
iTrader: (2)
 
Joined: Sep 2013
Posts: 266
Total Cats: 7
From: Pittsburgh PA
Default

Thanks, I wasn't sure if the Megasquirt would report the same values if it lost contact with the CANEGT. I'll look over my connections and LC-2 setup when I get home.
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
Carloverx
MEGAsquirt
12
Feb 16, 2019 10:13 PM
lyonnate23
MEGAsquirt
1
Nov 19, 2016 05:56 PM
Yuen74
Race Prep
30
Nov 2, 2016 06:41 AM
spag
MEGAsquirt
4
Oct 31, 2016 07:17 AM
Aussie Driver
MEGAsquirt
33
May 21, 2006 07:50 AM




All times are GMT -4. The time now is 02:04 PM.