Injector timing coolant temp based?
Hi,
i am having a small issue with my injector timing.
The injector timing table is set to "360", however when the engine coolant gets to 70*~ the injector timing goes down to 84~.
It happens every time.
I don't understand what causing this behaviour as the injector timing table doesn't use coolant temp.
Any idea what causing this and why?
The value that i am talking about is "injector timing pri" in the megalog viewer.
Log and tune are attached.
Thanks!
i am having a small issue with my injector timing.
The injector timing table is set to "360", however when the engine coolant gets to 70*~ the injector timing goes down to 84~.
It happens every time.
I don't understand what causing this behaviour as the injector timing table doesn't use coolant temp.
Any idea what causing this and why?
The value that i am talking about is "injector timing pri" in the megalog viewer.
Log and tune are attached.
Thanks!
Ok, it seems to happen because the vvt is going into action at 70*, and there is an option on the vvt settting "adjust inj. timing based on", mine is set to "cam1", what is the recommanded option?