MS is dead after cleaning with acetone
Thread Starter
Junior Member
iTrader: (4)
Joined: Oct 2007
Posts: 245
Total Cats: 1
From: santa cruz
I built a MSI V3.0 and passed all tests up to and including step 55.
Controlled Megatune gages with Stim pots.
Finished building board to the end.
Washed board with acetone and re-inspected all joints. Everything was spick and span.
Woke up this morning and hooked MS to DB9 cable and Stim and I get nothing. Fresh battery. Nothing. Double checked my cable, jumped pins 2&3 and got echo. Plugged cable back into MS, jumped U1 pins 12 & 13, no echo. If I jump DB9 pins 2 & 3 on the board, I get appropriate echo so I know DB9 cable is connected to MS.
Stuck at test in step 26.g.
Pin 4 of processor shows 32.76hz
Testing on the MAX232 shows
Pin 16 is 4.95
Pin 15 = 0.6 Ω to the middle pin of U5
Pin 11 to CPU Pin12 = ~0.3 Ω
Pin 12 to CPU pin 13 ~0.3 Ω
Power supply testing on U1 pins all succesful.
I have 5 volts between pins 19 (ground) and 20 (+5), there is also +5 on pin 1 and 31 (checked against ground at pin 19), and there is ground potential on pins 2 and 32 (checked against +5V on pin 20). The processor has power on the 40-pin socket but none of the LEDs on the MS respond. Capacitors with polarity and all diodes were triple checked for correct orientation and all checks out.
As I stated before, everything passed testing up to and including step 55. Then I brushed off the flux with acetone, gently blew it off with compressed air and waited approx. 12 hours. Hooked back up and now I don’t get response.
I’ve spent several hours searching and troubleshooting and I’d greatly appreciate any assistance.
Thanks
Controlled Megatune gages with Stim pots.
Finished building board to the end.
Washed board with acetone and re-inspected all joints. Everything was spick and span.
Woke up this morning and hooked MS to DB9 cable and Stim and I get nothing. Fresh battery. Nothing. Double checked my cable, jumped pins 2&3 and got echo. Plugged cable back into MS, jumped U1 pins 12 & 13, no echo. If I jump DB9 pins 2 & 3 on the board, I get appropriate echo so I know DB9 cable is connected to MS.
Stuck at test in step 26.g.
Pin 4 of processor shows 32.76hz
Testing on the MAX232 shows
Pin 16 is 4.95
Pin 15 = 0.6 Ω to the middle pin of U5
Pin 11 to CPU Pin12 = ~0.3 Ω
Pin 12 to CPU pin 13 ~0.3 Ω
Power supply testing on U1 pins all succesful.
I have 5 volts between pins 19 (ground) and 20 (+5), there is also +5 on pin 1 and 31 (checked against ground at pin 19), and there is ground potential on pins 2 and 32 (checked against +5V on pin 20). The processor has power on the 40-pin socket but none of the LEDs on the MS respond. Capacitors with polarity and all diodes were triple checked for correct orientation and all checks out.
As I stated before, everything passed testing up to and including step 55. Then I brushed off the flux with acetone, gently blew it off with compressed air and waited approx. 12 hours. Hooked back up and now I don’t get response.
I’ve spent several hours searching and troubleshooting and I’d greatly appreciate any assistance.
Thanks
I've damaged a processor before so if everything else checks out don't rule out a dead processor as a possibility. Anyone near you have an MS so you can try out their chip?