MS2 fan control
2 Attachment(s)
Hi,
I have a MS2 built by reverant. When I switch on the ignition the fan starts and does not stop. (engine cold). At approx 80-84 deg C the thermostat opens and coolant flows into the radiator. As far as I can see in the output port settings the fan is switch on/off depending on the coolant temp. I have had overheating problems on track and don't know if my fan is contributing to them. Its probably a airflow through my rad problem, but I would like to know how to control the fan anyway. Can anyone help |
enhanced unit?
|
What's the serial number on the unit?
|
4 Attachment(s)
Wow, that was quick Reverant. I can't get to the car today to check the serial no. but i did take these pics of inside a while ago. It was built for stuart-oxford on mx5nutz about sept last year. If this dosn't help I will get the serial tomorrow.
Thanks again for quick response. |
Did you happen to load another person's basemap by any chance? Fan control on this unit is on the Warmup LED.
|
Eh, yes actually and I thought it worked perfectly. So what does the warmup out do? Will I change anything?
|
copy settings from accel led to warmup led.
|
4 Attachment(s)
Just noticed I also have coolant settings in PAO too
|
this is why loading random maps is stupid
|
Originally Posted by Braineack
(Post 895210)
copy settings from accel led to warmup led.
I agree with not loading other peoples maps, but the map I had didn't start the car. I found this map on here, it was the very same spec car so I tried it. It started and apart from this I have had no problems. |
look on the board and see what ALED etc is wired to. that will tell you what it (might) be used for.
|
its one your spark outputs. it's overriding anything set in the outputs...
|
Accel LED and Injection LED are spark outputs on ALL of my units, Enhanced or not.
|
Originally Posted by Braineack
(Post 895210)
copy settings from accel led to warmup led.
|
Two questions:
Why are none of my outputs checked "enabled"? I can simply lower RPM value to zero and the fan will run when the engine is not running but key is on "ACC", right?
Originally Posted by Braineack
(Post 895222)
this is why loading random maps is stupid
|
1. if you have a a reverant enhanced ms2, he doesn't use the MS2 cpu to control the fan.
2. not sure, in ms3 we have a parameter under the fan control section that allows you to enable to fan with power or not. |
Originally Posted by hustler
(Post 905793)
Two questions:
Why are none of my outputs checked "enabled"? I can simply lower RPM value to zero and the fan will run when the engine is not running but key is on "ACC", right? 404.invert.spark This saves 2 outputs on the MS, which are free for you to use on anything else, like programmable outputs or sequential ignition. |
Originally Posted by Reverant
(Post 906071)
I have moved fan control from the MS processor board, to my expansion board.
This saves 2 outputs on the MS, which are free for you to use on anything else, like programmable outputs or sequential ignition. |
They are not adjustable on the current model, they are on the next-gen.
|
Originally Posted by Reverant
(Post 906129)
They are not adjustable on the current model, they are on the next-gen.
I'm planning on getting my Reverant MS2v3 setup in the next week or so, if the fans are identical to stock then I'd like to perform the "parallel fan" wiring mod. If not and the 2nd A/C fan will switch on at a pre-determined temp without the A/C active then the mod would be un-necessary. Thanks! |
All times are GMT -4. The time now is 05:44 AM. |
© 2024 MH Sub I, LLC dba Internet Brands