Sokool 03-20-2013 06:12 PM

MS3 EGT settings problem. Can't use a value less then -40
 
I'm running a digital analog faced AEM EGT gauge (30-5131). My problem is AEM thought it would be cool to make 0.5v = 0 degrees F and 4.5v = 1800 degrees F. That gives a formula of 450 * V - 225 = EGT Temp. Well at 0.0v that gives a value of -225. Tunerstudio won't let me input a value under -40. Is there work around for this or am I screwed? In the mean time I'm using a generic sensor input, which lets me input -225, to be able to log EGT but would like to use the built in safety system if I could.

HELP!

Braineack 03-20-2013 07:44 PM

post on msextra, see if ken or james can make you a new firmware to fix.

Sokool 03-20-2013 10:01 PM

That was my next stop. I like asking you guys better.

Reverant 03-21-2013 02:13 AM

Edit the .ini file to allow inputing -255.

Ben 03-22-2013 11:48 AM


Originally Posted by Sokool (Post 992009)
I'm running a digital analog faced AEM EGT gauge (30-5131). My problem is AEM thought it would be cool to make 0.5v = 0 degrees F and 4.5v = 1800 degrees F. That gives a formula of 450 * V - 225 = EGT Temp. Well at 0.0v that gives a value of -225. Tunerstudio won't let me input a value under -40. Is there work around for this or am I screwed? In the mean time I'm using a generic sensor input, which lets me input -225, to be able to log EGT but would like to use the built in safety system if I could.

HELP!

I didn't check your math, but since the output is linear, why not calculate the -40° value?

450V -225 = -40
450V = 185
V = .41
-40° = .41v

Braineack 03-22-2013 12:03 PM

but doesn't the MS3 software specifically ask for the 0v value, so what he's saying is that 0v = -255°F

if 0.5v=0°F and 4.5v = 1800°F

it's not asking for the voltage at -40°F...

Sokool 03-22-2013 04:27 PM

Brain is correct...

Sokool 03-24-2013 01:55 PM

I decided to update to 1.2.1 today and before I assigned the .ini I went ahead and fixed the egtcal_temp0 from -40 to -255. Works like a charm!

Reverant 03-24-2013 02:01 PM

Yay!

Sokool 03-24-2013 03:16 PM

2 Attachment(s)
Spoke too soon... It lets me put in a value of -225 now but now it constantly shows EGT as -100. Switch back to using generic inputs and it will display fine.... What went wrong? Added my .msq for gigs.