Resistance vs temperature points for 1.6 AFM ?
I am sure this is well known, but I swear I've searched in every place I can think of and I can't find it. :noob:
Don't make me measure it. Anyone? I need it for here: http://www.boost-instruments.com/ms/tablegen.PNG (The flapper will go away eventually but not right now.) |
I got this out of the enthusiast's manual:
-20C: 13,600-18,400 20C: 2,210-2,690 60C: 493-667 Is that for the MS2? I don't remember seeing that dialog. |
Everyone says to use the RX7 defaults in Easytherm (which I know you don't have since you're MS2) so here they are:
-20°C = 16,200 20°C = 2,450 80°C = 320 I can't vouch for these since I never ran the AFM (or its sensor) but nobody has complained so far. |
These are the values we use.
-4 degrees F / 16000 ohms 68 degrees F / 2450 ohms 140 degrees F / 580 ohms |
Thanks guys.
Yes, this is for MS2-Extra. I guess I should do some sort of writeup when I'm done, since everybody else seems to be running MS1-Extra... |