What is going on with my AFR
3 Attachment(s)
Suddenly this started to happen after I changed my idle to openloop en played with my air density table:
Attachment 230542 I know the idle and air density settings shouldn't matter so could it be a defective wideband? It's a innovate mtx something with the LSU 4.9 sensor. Oh and btw, I ran a little too rich last week because of a major human error . That rich that there was a lot of unburned fuel in the exhaust and a huge cloud of black smoke. I calibrated the sensor yesterday so that couldn't be it.. |
What I would suggest you try, based on the picture.
Turn off EGO and see if oscillation goes away. If it does, then that is your cause. I believe that it is. |
Originally Posted by DNMakinson
(Post 1387651)
What I would suggest you try, based on the picture.
Turn off EGO and see if oscillation goes away. If it does, then that is your cause. I believe that it is. |
your cl ego control is probably set to adjust too fast and too aggressive
|
All times are GMT -4. The time now is 12:55 PM. |