MEGAsquirt A place to collectively sort out this megasquirt gizmo

Idle valve sometime close right after startup

Thread Tools
 
Search this Thread
 
Old 07-25-2019, 01:49 PM
  #1  
Newb
Thread Starter
 
p0staldude's Avatar
 
Join Date: Oct 2014
Posts: 37
Total Cats: 3
Default Idle valve sometime close right after startup

I have been tuning my MS3x for the last week and there is an annoying issue that I haven't managed to fix. Sometime, right after startup (doesn't matter if the car is hot or cold), the megasquirt will close the idle valve abruptly stalling the engine. If I try to restart the car right after it usually does not do it, the idle valve slowly close to bring the RPM down.

Any idea what could cause this? In the attached log you can see at 33 seconds the idle valve closing from 36% duty cycle to 20% duty cycle. At 40 seconds I restart the car and you can see the idle valve slowly closing after
Attached Files
File Type: msl
IdleValveProblem.msl (1.33 MB, 49 views)
File Type: msq
CurrentTune.msq (287.3 KB, 35 views)
p0staldude is offline  
Old 07-25-2019, 03:23 PM
  #2  
Junior Member
 
HowPrayGame's Avatar
 
Join Date: Oct 2018
Location: Tampa FL
Posts: 412
Total Cats: 28
Default

Are your closed loop idle initial values too low? I forgot how that table is scaled but it looks like the values between 700 rpm and 900 rpm would interpolate to something around 20%
HowPrayGame is offline  
Old 07-25-2019, 05:16 PM
  #3  
Newb
Thread Starter
 
p0staldude's Avatar
 
Join Date: Oct 2014
Posts: 37
Total Cats: 3
Default

Originally Posted by HowPrayGame
Are your closed loop idle initial values too low? I forgot how that table is scaled but it looks like the values between 700 rpm and 900 rpm would interpolate to something around 20%
Under closed loop I have the Crank to Run Taper setting set to 5 seconds, shouldn't it gradually decrease the duty cycle to 20% instead of going to 20% straight away?
p0staldude is offline  
Old 07-25-2019, 05:21 PM
  #4  
Junior Member
 
HowPrayGame's Avatar
 
Join Date: Oct 2018
Location: Tampa FL
Posts: 412
Total Cats: 28
Default

Yes, I am just wondering as your min values for your idle valve are starting at 16%, and 20% is barely opening the idle valve at all. You might want to give the car more air when its warming up so it doesn't stall, that's sounds like what is happening. Depends on how far in your idle bypass screw is
HowPrayGame is offline  
Old 07-25-2019, 06:22 PM
  #5  
Newb
Thread Starter
 
p0staldude's Avatar
 
Join Date: Oct 2014
Posts: 37
Total Cats: 3
Default

One more question, is there a way to know if closed loop was active at a specific time with just the log?
p0staldude is offline  
Old 08-02-2019, 07:19 PM
  #6  
Junior Member
iTrader: (2)
 
konmo's Avatar
 
Join Date: Dec 2014
Location: Salinas, CA
Posts: 307
Total Cats: 23
Default

What firmware are you on? If on the latest, could be your engine states not set correctly.
konmo is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
ravinaziankid
MSPNP
3
01-06-2019 11:17 PM
Fatvod
MEGAsquirt
5
10-31-2015 12:01 AM
elior77
MEGAsquirt
15
11-05-2014 03:06 AM
miatauser884
MEGAsquirt
19
08-28-2012 11:21 PM
hustler
MEGAsquirt
2
12-13-2008 04:50 PM



Quick Reply: Idle valve sometime close right after startup