Alternator suddenly red hot?

Old Jul 15, 2019 | 03:26 PM
  #61  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

It's still odd to me it only gets hot upstream of the relay, at the relay itself, and nowhere else, even if that wire is much larger diameter. But I don't have an EE.

I went ahead and bought a AC/DC amp meter from Amazon for $30 because of Deal Days sale:

Amazon Amazon

One day it will be used.
Old Jul 15, 2019 | 03:27 PM
  #62  
Godless Commie's Avatar
Elite Member
iTrader: (2)
 
Joined: Jun 2009
Posts: 3,227
Total Cats: 1,707
From: Istanbul, Turkey
Default

I would kindly remind you of post number two in this thread, Steve.

Specifically the sentences talking about physical obstructions to the fan and free rotation and such.

"I would start with the fans, to see if there are any physical obstructions keeping them from rotating freely.
Next, I would check how much power (amps) they are drawing.


These two steps would eliminate the biggest source of power consumption if they check out fine."
Old Jul 15, 2019 | 03:58 PM
  #63  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Originally Posted by Godless Commie
I would kindly remind you of post number two in this thread, Steve.

Specifically the sentences talking about physical obstructions to the fan and free rotation and such.

"I would start with the fans, to see if there are any physical obstructions keeping them from rotating freely.
Next, I would check how much power (amps) they are drawing.


These two steps would eliminate the biggest source of power consumption if they check out fine."
You are correct, as usual.

It turned easily by hand and I didn't have an amp meter yet so I did what I could. The fan must have something wrong internally to draw so much more startup energy than it once did. The fan was the most expensive piece to replace at $125 plus shipping. The 80a relay was only $4. I already had the 10 gauge fuse holder in my box of electrical connections. I'm glad the other components are now upsized for reliability regardless of the extra trouble I went to.
Old Jul 15, 2019 | 04:11 PM
  #64  
skylinecalvin's Avatar
Junior Member
iTrader: (2)
 
Joined: Apr 2016
Posts: 486
Total Cats: 89
Default

Originally Posted by sixshooter
It's still odd to me it only gets hot upstream of the relay, at the relay itself, and nowhere else, even if that wire is much larger diameter. But I don't have an EE.

I went ahead and bought a AC/DC amp meter from Amazon for $30 because of Deal Days sale:

https://www.amazon.com/dp/B0721MKXBC..._LEglDb13E00RC

One day it will be used.
Impulse buy of the day.
Old Jul 17, 2019 | 09:58 AM
  #65  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Spal advises using 40 amp fuse and 40 amp relay with this fan! Running draw is 18 or 21 maximum depending upon where you read, and I know startup is higher.


Really surprised they use 14 gauge wire.
Attached Thumbnails Alternator suddenly red hot?-20190717_092056.jpg   Alternator suddenly red hot?-20190717_092038.jpg  
Old Jul 17, 2019 | 12:09 PM
  #66  
SpartanSV's Avatar
Senior Member
 
Joined: Apr 2017
Posts: 1,232
Total Cats: 169
From: Greeley, CO
Default

Originally Posted by sixshooter
Spal advises using 40 amp fuse and 40 amp relay with this fan! Running draw is 18 or 21 maximum depending upon where you read, and I know startup is higher.


Really surprised they use 14 gauge wire.
Did you use their wiring kit and it was 14 gauge the whole way? Or was it just a short length of wire off the motor that was 14 gauge?
Old Jul 17, 2019 | 01:12 PM
  #67  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Originally Posted by SpartanSV
Did you use their wiring kit and it was 14 gauge the whole way? Or was it just a short length of wire off the motor that was 14 gauge?
I did not buy their kit. Their wire is at least 24 in from the fan motor. I will hopefully get a closer look at the new one tonight. I'm reasonably confident my 10 and 12 gauge wire with 80 amp relay will be more substantial.

Is it possible my 30 amp fuse was just never large enough and that created heat in just that wire and relay? Do not know if that's possible.
Old Jul 17, 2019 | 01:44 PM
  #68  
Joe Perez's Avatar
Boost Pope
iTrader: (8)
 
Joined: Sep 2005
Posts: 34,402
Total Cats: 7,523
From: Chicago. (The less-murder part.)
Default

Originally Posted by sixshooter
Is it possible my 30 amp fuse was just never large enough and that created heat in just that wire and relay? Do not know if that's possible.
Weird stuff can happen when you restrict large currents.

During the runup to the 2016 presidential election, when I was working in New York, one of our news vans was out at the Democratic National Convention in Philly. Due to a snafu in the booking, the venue provided us with ashore-power connector that we didn't have the proper cable for. (It was a 3 phase, 50 amp circuit, and the truck expects single-phase 120v 30A.) Rather foolishly, the truck operator cobbled together a collection of adapters and cables which allowed him to plug in the truck, and part of this consisted of a 20 foot extension cord with a 15 amp plug and rating, I think it was an 18 AWG cable.

Anyway, he fires up the truck, gets the air conditioner going, raises the satellite dish and fires up the transmitter, and basically just starts doing truck stuff. And it works for a while. Then he starts to smell something. Something burn-ey.

Long story short, the 30A power receptacle on the side of the truck was melting. The 15A extension cord was also in poor shape, but the big 30A twist-lock plug going into the side of the truck was sagging about 20° from horizontal, and smoke was coming out of it.

I have utterly no idea what caused that.

Humorous coda: when you're parked inside the secure area at the Democratic National Convention, surrounded by FBI and Secret Service, you don't want smoke to be coming out of your vehicle. That makes the men with the guns nervous.
Old Jul 17, 2019 | 02:03 PM
  #69  
gooflophaze's Avatar
Senior Member
 
Joined: May 2007
Posts: 997
Total Cats: 156
From: Atlanta
Default

A fuse is just a short wire that burns. Wire ampacity is somewhat rated similarly - it's not that copper burns if you go over X amps for a certain gauge, the sheath melts. PVC covering melts much lower than TXL. 14ga is perfectly sufficient for a foot at 20a sustained if the sheathing doesn't melt. Smaller gauge does accrue higher resistance - that resistance is converted to heat.

The main critique I have of your setup is your crimper - I'm not a fan of stake crimpers - they're very inconsistent, tend to pierce coverings, only really contact a small area that leaves the rest of the wire open to oxidation. A ratcheting crimper is betterer - repeatable crimps that compress a larger area, won't pierce the heatshrink buttsplices I like to use (oxidation), better conduction. I suspect you've got a bad joint on the relay - and that heat is conducting down the line somewhere.

I'm pretty much guessing at this point though - mostly because of my hatred for stake crimps.
Old Jul 17, 2019 | 02:57 PM
  #70  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

I Googled ratcheting crimper and I think I own one. I didn't buy it, I inherited a bunch of electrical stuff from a guy who installed home audio and electronic systems for many years. I've got boxes of thousands of crimp connectors, most of them red ones with various ends to be screwed down or otherwise connected.

I also inherited a telephone receiver that has a couple of clamps on wires hanging out of it. I guess you could go up to someone's exterior phone box and make long-distance calls.
Old Jul 17, 2019 | 03:07 PM
  #71  
gooflophaze's Avatar
Senior Member
 
Joined: May 2007
Posts: 997
Total Cats: 156
From: Atlanta
Default

https://www.summitracing.com/ga/parts/ttn-11477 is what I currently have after my original one wore out. https://www.harborfreight.com/30-pac...ors-66729.html are in my box for less-critical joints, https://www.delcity.net/store/Perma!...12022.h_812023 have a longer barrel and better seal.
Old Jul 17, 2019 | 04:47 PM
  #72  
Joe Perez's Avatar
Boost Pope
iTrader: (8)
 
Joined: Sep 2005
Posts: 34,402
Total Cats: 7,523
From: Chicago. (The less-murder part.)
Default

Originally Posted by sixshooter
I also inherited a telephone receiver that has a couple of clamps on wires hanging out of it. I guess you could go up to someone's exterior phone box and make long-distance calls.
When I was in high school, a friend and I did exactly this. We typically would open the green can in the neighborhood, rather than hitting individual houses.

I also kind of agree w/ gooflophaze about your crimper. It's not impossible to make a good crimp with the one you have, but using a ratcheting crimper makes it easier and more pleasant. I own two of them. (One at home, one at work.)
Old Jul 20, 2019 | 01:16 PM
  #73  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Old fan running- 21.5 amps
New fan running- 22.4 amps

Resistance across relay- 151 ohms
Resistance across fuse and its wire (measured at relay and main 80a fuse output)- 22 ohms

Fuse wire temperature around 245 degrees Fahrenheit during continuous operation of fan. 80a relay also hot. All other wires good temp.

Power entering main 80a fuse 13.8-14v.

Fan ground wire to chassis was replaced with 10 gauge now.

I'm not sure what the max temperature of the relay, wire, or fuse holder might be but it seems warm.

Heading to Lowe's for the reccomended crimper. Not sure what to do otherwise. Maybe I'll increase the size of the high current lead from the relay to the fan to 10 gauge.

40 amp fuse is holding.

I'm lost unless this type of heat is in the realm of acceptability. Totally lost.
Attached Thumbnails Alternator suddenly red hot?-1563642971579.jpg   Alternator suddenly red hot?-20190720_130341.jpg  

Last edited by sixshooter; Jul 20, 2019 at 01:48 PM.
Old Jul 20, 2019 | 02:06 PM
  #74  
Ted75zcar's Avatar
Tweaking Enginerd
iTrader: (2)
 
Joined: Mar 2013
Posts: 1,873
Total Cats: 383
From: Boulder, CO
Default

Those resistance measurements are whack. 20A through 151 ohms would be ~3000 volts.

Do you have any local friends who are EEs or electronics technicians?

This honestly shouldn't be this complicated.
Old Jul 20, 2019 | 03:24 PM
  #75  
DNMakinson's Avatar
Elite Member
iTrader: (3)
 
Joined: Jan 2013
Posts: 5,030
Total Cats: 861
From: Seneca, SC
Default

Originally Posted by Ted75zcar
Those resistance measurements are whack. 20A through 151 ohms would be ~3000 volts.

Do you have any local friends who are EEs or electronics technicians?

This honestly shouldn't be this complicated.
I'm guessing that was the coil reading. 1.1 watt coil is sensible.

EDIT: However, if across the contacts, one does not know if contacts are fritted or not, so a low voltage measurement is not valid. Much better to measure current and voltage drop on a set of closed contacts. Especially Silver Tin Oxide.

EDIT(2): 22 Amps should not blow a 30A fuse, whether slow or fast acting. IIRC, your fuse did not blow on start-up or locked rotor, but after fan was running for a minute or so.

Is Alternator hot?
Old Jul 20, 2019 | 03:41 PM
  #76  
Joe Perez's Avatar
Boost Pope
iTrader: (8)
 
Joined: Sep 2005
Posts: 34,402
Total Cats: 7,523
From: Chicago. (The less-murder part.)
Default

Originally Posted by sixshooter
Resistance across relay- 151 ohms
This seems wrong.

Assuming 14v and 20a, that's 280 watts being dissipated across the relay. While this is less than the output of the sun, it's quite a bit more than any normal relay could sink without bursting into flame.

I'm not exaggerating here. 280 watts across the contacts of automotive style relay would cause it to melt, and emit smoke and fire.

Old Jul 20, 2019 | 07:15 PM
  #77  
SpartanSV's Avatar
Senior Member
 
Joined: Apr 2017
Posts: 1,232
Total Cats: 169
From: Greeley, CO
Default

Originally Posted by Joe Perez
This seems wrong.

Assuming 14v and 20a, that's 280 watts being dissipated across the relay. While this is less than the output of the sun, it's quite a bit more than any normal relay could sink without bursting into flame.

I'm not exaggerating here. 280 watts across the contacts of automotive style relay would cause it to melt, and emit smoke and fire.
That's obviously the resistance across the coil. Totally reasonable value.
Old Jul 20, 2019 | 07:16 PM
  #78  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Switched to the other 80a relay (it was a two pack) and measured an identical 151 ohms when contacts closed and fan running. Not normal?

I changed the fuse holder wire segments out and ran a new 10 gauge wire (employing better crimpers) from the fuse block to the 40a fuse and from the 40a fuse to the 80a relay.

I employed a new 10 gauge wire from the relay to the fan utilising macho crimpers.

I moved the fan ground wire (already 10 gauge) to a different chassis location and made use of a star washer to ensure excellent contact. I also re-squoze the crimp.

Tested.

Fuse wires not nearly as hot to the touch. Fuse itself gets warm but that's expected, I guess. Relay gets good and warm but not as bad.

Startup for fan measured at 31amps for a flash and then steady at 22 amps.

I'm trying to decide if this is workable. If it keeps working and there's no fire = solution?

Should I just send it?
Old Jul 20, 2019 | 07:18 PM
  #79  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Originally Posted by Ted75zcar
This honestly shouldn't be this complicated.
The gravity of this reality is not lost on me.
Old Jul 20, 2019 | 07:20 PM
  #80  
sixshooter's Avatar
Thread Starter
Moderator
iTrader: (12)
 
Joined: Nov 2008
Posts: 22,204
Total Cats: 3,560
From: Tampa, Florida
Default

Originally Posted by SpartanSV
That's obviously the resistance across the coil. Totally reasonable value.
As a reply to you and DKM:
Not resistance across the coil, unfortunately. That's the 30 to 87 resistance while contacted.

And I didn't grab the new alternator to check if warm.