When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
Running two thermistor NTC sensor on MS3 FW 1.5.1 possible ?
Hi,
I've got an issue with Tunerstudio / my MS3 FW 1.5.1
I'm trying to run two different thermistor temperature sensors via generic sensor inputs. But I can only calibrate one thermistor curve via *.inc file import > custom#1 temperature sensor calibration.
How can i run two different calibration tables for an oil and fuel temperature sensor in Tunerstudio / on my MS3 ?
Creating a custom channel as a workaround will display a second sensor with different curve, but then I can't use in the oil pressure / fuel pressure setting and trigger actions with it.
Also - I can't broadcast the information via CAN Broadcast when it's coming from a custom channel, correct ?
kind regards
Unfortunately there is no way to do that. You will need to use the same sensor type for both sensors OR use a GM sensor OR use CLT sensor you use as a temperature sensor.