DIY Turbo Discussion greddy on a 1.8? homebrew kit?

Coolant supply options.

Thread Tools
 
Search this Thread
 
Old 01-26-2008, 10:39 PM
  #1  
Elite Member
Thread Starter
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default Coolant supply options.

What kind of thread is on the coolant ports, I am looking for options other then banjo bolts to get coolant in and out of the turbo.

Maybe a 90 degree with a barb, if there is such a thing? I doubt a straight barb will clear the manifold.
Saml01 is offline  
Old 01-26-2008, 10:52 PM
  #2  
Elite Member
iTrader: (13)
 
cjernigan's Avatar
 
Join Date: Oct 2006
Location: Atlanta, GA
Posts: 8,091
Total Cats: 7
Default

anplumbing.com
cjernigan is offline  
Old 01-26-2008, 11:22 PM
  #3  
Elite Member
Thread Starter
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default

What size is that?
Saml01 is offline  
Old 01-26-2008, 11:32 PM
  #4  
Elite Member
iTrader: (13)
 
cjernigan's Avatar
 
Join Date: Oct 2006
Location: Atlanta, GA
Posts: 8,091
Total Cats: 7
Default

http://www.anplumbing.com/shop/index...&dept=Aluminum
Any size you want, scroll down.
cjernigan is offline  
Old 01-27-2008, 01:06 AM
  #5  
Elite Member
Thread Starter
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default

So the banjo bolts are M14 x 1.5 pitch.

I was thinking of getting two of these.
http://www.atpturbo.com/Merchant2/me..._Code=ATP-FTG1
and some 90 degree -6an -> 3/8 barbs if such a thing exists or just a -6 to -6 90 degree adapater and a -6an to 3/8 barb.

Last edited by Saml01; 01-27-2008 at 01:23 AM.
Saml01 is offline  
Old 01-27-2008, 03:12 AM
  #6  
Elite Member
iTrader: (6)
 
kenzo42's Avatar
 
Join Date: Sep 2007
Location: CA
Posts: 2,016
Total Cats: 13
Default

Sorry to threadjack, but is the only reason to upgrade these is for clearance reasons? I was hoping I could use what came on the turbo:

Name:  Photo0075.jpg
Views: 74
Size:  39.7 KB
kenzo42 is offline  
Old 01-27-2008, 03:15 AM
  #7  
Former Vendor
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,100
Default

Kenzo, for the outside you are fine, but on the inside the issue is that the water line goes straight into the manifold. Your turbo isn't clocked right in that photo; the oil drain needs to point down, and once you do that you'll see that the inner coolant barb will need to be changed.
Savington is offline  
Old 01-27-2008, 10:57 AM
  #8  
Elite Member
Thread Starter
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default

^ Savington, you're saying even with what I outlined in my last post, I may still hit the manifold with the fittings?
Saml01 is offline  
Old 01-27-2008, 11:15 AM
  #9  
Elite Member
iTrader: (7)
 
samnavy's Avatar
 
Join Date: Apr 2006
Location: VaBch, VA
Posts: 6,451
Total Cats: 322
Default

Another consideration is the heat-transfer properties of aluminum vs. brass. I'm pretty sure that brass is a better conductor of heat. The CHRA gets pretty ******* hot... transferring the heat through your barb and into the hose. Typical coolant hoses aren't designed for that kind of heat. I've never heard of hose melting to a barb... if that's how I did it, I'd probably replace those hoses every year or so for preventative maint.
samnavy is offline  
Old 01-27-2008, 11:55 AM
  #10  
Junior Member
iTrader: (3)
 
mx5roadster's Avatar
 
Join Date: Jul 2005
Location: AL
Posts: 206
Total Cats: 0
Default

Originally Posted by cjernigan
anplumbing.com
Thanks for that site, the stuff on there is way cheaper than I've found before.
mx5roadster is offline  
Old 01-27-2008, 12:57 PM
  #11  
Elite Member
Thread Starter
iTrader: (9)
 
Saml01's Avatar
 
Join Date: Jul 2007
Location: NYC
Posts: 5,710
Total Cats: 3
Default

Originally Posted by samnavy
Another consideration is the heat-transfer properties of aluminum vs. brass. I'm pretty sure that brass is a better conductor of heat. The CHRA gets pretty ******* hot... transferring the heat through your barb and into the hose. Typical coolant hoses aren't designed for that kind of heat. I've never heard of hose melting to a barb... if that's how I did it, I'd probably replace those hoses every year or so for preventative maint.
I doubt its gonna get hot enough to melt rubber, but I am also planning to use the same type of hose for the coolant as the oil drain.
Saml01 is offline  
Old 01-27-2008, 01:45 PM
  #12  
Senior Member
iTrader: (1)
 
PaKMaN's Avatar
 
Join Date: Oct 2006
Location: Burbank, CA
Posts: 536
Total Cats: 0
Default

Name:  Photo0075.jpg
Views: 62
Size:  39.7 KB


I have SS water lines and have these gold things at the end with a 2 inch rubber line that goes from the gold thing to the water pump's nipples.
PaKMaN is offline  
Old 01-27-2008, 04:08 PM
  #13  
Junior Member
 
BIGTURBO's Avatar
 
Join Date: Dec 2005
Location: Greece, athens
Posts: 98
Total Cats: 0
Default

I am advising to not try silicone hoses there but make high pressure stainless steel water lines (like the brakes).You will pay for one and last time
BIGTURBO is offline  
Old 01-27-2008, 04:15 PM
  #14  
Elite Member
iTrader: (13)
 
cjernigan's Avatar
 
Join Date: Oct 2006
Location: Atlanta, GA
Posts: 8,091
Total Cats: 7
Default

Originally Posted by Saml01
I doubt its gonna get hot enough to melt rubber, but I am also planning to use the same type of hose for the coolant as the oil drain.
Turbine housings get hot enough to glow red, the chra and fittings for coolant are what.. 1" away at most. It gets hot enough.
cjernigan is offline  
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
slomiata
MEGAsquirt
5
10-07-2015 01:11 PM
FrankB
Race Prep
10
10-02-2015 09:00 PM
shooterschmidty
Engine Performance
8
09-30-2015 10:28 PM



Quick Reply: Coolant supply options.



All times are GMT -4. The time now is 05:46 AM.