Old Oct 21, 2015 | 01:28 AM
  #4721  
patsmx5's Avatar
Elite Member
iTrader: (16)
 
Joined: Aug 2007
Posts: 9,406
Total Cats: 559
From: Houston, TX
Default

Originally Posted by aidandj
How did you run wires through the bulkhead?
Drilled a hole, ran wire through it, sealed it with JB quick weld.
Old Oct 21, 2015 | 01:31 AM
  #4722  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

Originally Posted by patsmx5
Drilled a hole, ran wire through it, sealed it with JB quick weld.
Any issue with fuel wicking up the wire?
Old Oct 21, 2015 | 01:32 AM
  #4723  
patsmx5's Avatar
Elite Member
iTrader: (16)
 
Joined: Aug 2007
Posts: 9,406
Total Cats: 559
From: Houston, TX
Default

Originally Posted by aidandj
Any issue with fuel wicking up the wire?
No, I did it out of the car obviously. It's sealed and then reinstalled.
Old Oct 21, 2015 | 01:38 AM
  #4724  
deezums's Avatar
Elite Member
iTrader: (3)
 
Joined: May 2014
Posts: 3,146
Total Cats: 206
From: Kansas
Default

Something to watch out for is thermal runaway, I don't think it'd be a problem with stock wire in the tank, but as you feed too much current through a small wire it will heat up, further increasing it's resistance which makes it heat up all the more, thermal runaway. It is killer of LEDs and laser diodes, unless fed constant current instead of fixed voltage.

It happens a lot in terminals on cars, headlights, the blower fan resistor coil in my Colorado, some piece of **** kia I fixed...

For wicking you can add a drip loop if it'd fit, maybe it'd help?

Old Oct 21, 2015 | 02:13 PM
  #4725  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

Originally Posted by patsmx5
No, I did it out of the car obviously. It's sealed and then reinstalled.
I don't mean while installing it. I mean while its sitting in the fuel.

Would a drip loop work with an insulated wire?
Old Oct 21, 2015 | 02:18 PM
  #4726  
patsmx5's Avatar
Elite Member
iTrader: (16)
 
Joined: Aug 2007
Posts: 9,406
Total Cats: 559
From: Houston, TX
Default

Originally Posted by aidandj
I don't mean while installing it. I mean while its sitting in the fuel.

Would a drip loop work with an insulated wire?
It's sealed, it's never going to leak. Mine I just ran the wires straight to the pump. It don't leak, I've pulled the cover to check it a couple times.

If it makes you feel all warm and fuzzy, I added a pick up tube for a fuel system for nitrous back in 2006 on this car. I tach welded it into the hanger, and JB-welded it to seal it. In 2006, and it still doesn't leak as of 10/21/2015.
Old Oct 21, 2015 | 02:20 PM
  #4727  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

I still don't mean leaking around the seal. I mean the wires submersed in fuel. Wicking up inside the insulation.
Old Oct 21, 2015 | 02:41 PM
  #4728  
patsmx5's Avatar
Elite Member
iTrader: (16)
 
Joined: Aug 2007
Posts: 9,406
Total Cats: 559
From: Houston, TX
Default

Originally Posted by aidandj
I still don't mean leaking around the seal. I mean the wires submersed in fuel. Wicking up inside the insulation.
Oh. Well I dunno, if it's a problem I haven't experienced it yet. I googled it and found a few people did what I did, so I did it. I guess if you're worried about it, I think about 100 dollars will buy a good connector, and 2-3 hundred buys the tools to crimp pins for it. Then you can add a metal connector that is sealed and better. That's the only easy way I know to improve this given that the hanger is steel. Maybe cut a section of steel out, epoxy a piece of plastic in its place, and then use threw bolts and connect to those. Lot of work, in the end would be better than what I did though.
Old Oct 21, 2015 | 08:02 PM
  #4729  
Leafy's Avatar
Elite Member
iTrader: (1)
 
Joined: Jun 2012
Posts: 9,491
Total Cats: 105
From: NH
Default

The connector from racetronix is actually for some dealer approved retrofit on GM cars or something like that. It was the best option I could find this side of a **** load of money. Pat they do sell insulated bolt terminals like you'd use to have battery lugs on the outside of a racecar and some people do use those with some globs of fuel rated rtv instead. If I was you though I'd have a sniff at the relay end of the wire poking out of your fuel tank and see if you can smell the gasoline thats probably inside the wire.
Old Oct 21, 2015 | 08:23 PM
  #4730  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

I'm leaning towards the bolt terminals. If I can find them cheap. Saw some for like $12 on a quick search, but **** that's halfway to the racetronix thing.
Old Oct 21, 2015 | 09:50 PM
  #4731  
hi_im_sean's Avatar
SadFab CEO
iTrader: (3)
 
Joined: Sep 2012
Posts: 4,560
Total Cats: 1,143
From: your mom's house phoenix, AZ
Default

You can get proper "open barrel" terminal crimpers for about $20 that cover about 2 to 3 different gauges.
Old Oct 21, 2015 | 09:55 PM
  #4732  
hi_im_sean's Avatar
SadFab CEO
iTrader: (3)
 
Joined: Sep 2012
Posts: 4,560
Total Cats: 1,143
From: your mom's house phoenix, AZ
Default

Molex Style Crimp Tool Wiring Harness Crimping Crimper Open Barrel 14 24 AWG | eBay
The $2-300, ratcheting, depth stopped, replaceable die crimpers are awesome, but not necessary.


Dont feel like deciphering the last 10 pages or whatever, but whats the deal with this bulk head connector obsession. You keep mentioning it, whats the problem? Cant find one you like? Are you over complicating **** again?
Old Oct 21, 2015 | 10:24 PM
  #4733  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

Fuel safe. Big wire. Not racetronix because they are ********.

I bought a walbro400 e85
Old Oct 21, 2015 | 10:47 PM
  #4734  
hi_im_sean's Avatar
SadFab CEO
iTrader: (3)
 
Joined: Sep 2012
Posts: 4,560
Total Cats: 1,143
From: your mom's house phoenix, AZ
Default

Originally Posted by aidandj
Fuel safe. Big wire. Not racetronix because they are ********.

I bought a walbro400 e85
Oh, so you want a bulk head connector for the gas tank? I can see that being difficult and expensive.

Having never messed with a miata gas tank- other than converting to the proper gauge, whats the issue with the stock "bulk head" connector?

Edit- goggle images answered my question. I have nothing to add at this point. Carry on.
Old Oct 21, 2015 | 10:49 PM
  #4735  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

Attached Thumbnails Aidan's loose oily bunghole actually runs a track lap-80-b2iywx8vjhoms2fk559k_a856a37f490025be0c654b84848951b9c77b70a7.jpg  
Old Oct 21, 2015 | 10:50 PM
  #4736  
Leafy's Avatar
Elite Member
iTrader: (1)
 
Joined: Jun 2012
Posts: 9,491
Total Cats: 105
From: NH
Default

Originally Posted by hi_im_sean
Having never messed with a miata gas tank- other than converting to the proper gauge, whats the issue with the stock "bulk head" connector?
Putting 14 or more amps though a connector thats probably not even rated for 12 amps going into a gas tank is scary.
Old Oct 21, 2015 | 10:52 PM
  #4737  
hi_im_sean's Avatar
SadFab CEO
iTrader: (3)
 
Joined: Sep 2012
Posts: 4,560
Total Cats: 1,143
From: your mom's house phoenix, AZ
Default

Originally Posted by Leafy
Putting 14 or more amps though a connector thats probably not even rated for 12 amps going into a gas tank is scary.
So what you are saying is, this is perfect for aidan?
Old Oct 21, 2015 | 10:59 PM
  #4738  
hi_im_sean's Avatar
SadFab CEO
iTrader: (3)
 
Joined: Sep 2012
Posts: 4,560
Total Cats: 1,143
From: your mom's house phoenix, AZ
Default

FD dudes be like




Triple-R: Engine Rebuild - Dual Fuel Pumps and Tank Improvements
Attached Thumbnails Aidan's loose oily bunghole actually runs a track lap-80-electricalbulkhead_b19d6931f4959a62ec0ba05bad2aa1f32fe1fc0d.jpg  
Old Oct 21, 2015 | 11:00 PM
  #4739  
Leafy's Avatar
Elite Member
iTrader: (1)
 
Joined: Jun 2012
Posts: 9,491
Total Cats: 105
From: NH
Default

Originally Posted by hi_im_sean
Yeah those are the sketchy things I mentioned earlier. You ever notice how often FDs catch on fire, especially during photoshoots...
Old Oct 21, 2015 | 11:01 PM
  #4740  
aidandj's Avatar
Thread Starter
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

Keep reading. He had to add a whole bunch of fuel safe sealant to make them work. What's the cheapest you can find those?