Besides additional nozzles, tubing, fittings and a manifold/splitter is there anything else you would need to add to a basic DO kit to do port WI?

Edit: DO has a kit to upgrade to 4/6/8 direct port kits. 4 port is about $62.
jayc72 is offline   Reply With Quote
Old 11-13-2009, 03:53 PM   #22
Elite Member
iTrader: (12)
 
Join Date: May 2007
Location: Austin, TX
Posts: 1,923
Total Cats: 0
Default

What's the consensus on the newer high pressure pumps that should improve atomization?
JayL is offline   Reply With Quote
Old 11-13-2009, 04:03 PM   #23
Elite Member
iTrader: (1)
 
Join Date: May 2009
Location: Jacksonville, FL
Posts: 4,682
Total Cats: 216
Default

Yah I put thse holes there for direct port nitrous back in the day, I wanted to get them as far upstream as possible to prevent reversion and help atomization. Should be ideal for water as well
Full_Tilt_Boogie is offline   Reply With Quote
Old 11-13-2009, 04:04 PM   #24
Elite Member
iTrader: (1)
 
Join Date: May 2009
Location: Jacksonville, FL
Posts: 4,682
Total Cats: 216
Default

Quote:
Originally Posted by jayc72 View Post
Besides additional nozzles, tubing, fittings and a manifold/splitter is there anything else you would need to add to a basic DO kit to do port WI?

Edit: DO has a kit to upgrade to 4/6/8 direct port kits. 4 port is about $62.
check valve or solenoid, its connecting into vacuum so you need it stop the water from being drawn out
Full_Tilt_Boogie is offline   Reply With Quote
Old 11-13-2009, 04:12 PM   #25
Senior Member
iTrader: (6)
 
Join Date: Jul 2007
Location: Cocoa Beach, FL
Posts: 808
Total Cats: 3
Default

Quote:
Originally Posted by ZX-Tex View Post
Like I said...
Yeah, totally missed that post. I must have written mine at the same time and didn't realize you posted.

I guess I need to order some more nozzles and such. Are you using a home built system or DO or ? on/off or progressive? what size nozzles?

I'm really interested in seeing how your setup works out.
TrickerZ is offline   Reply With Quote
Old 11-13-2009, 05:23 PM   #26
Elite Member
iTrader: (15)
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,889
Total Cats: 28
Default

No worries

It is a Devil's Own universal with additional fittings to split it into four ports. I am using DO 2 GPH external nozzles. It will be progressive, controlled by my Adaptronic, but not by pulsing the pump. I found a used Aquamist high-speed nozzle and will be using that, controlled via PWM from an aux output. I am leaning towards mapping the WI to the FI duty cycle; the Adaptronic can do this. It can map it to whatever you want really, so I could map it to RPM, MAP, throttle position, moon phase...
ZX-Tex is offline   Reply With Quote
Old 11-13-2009, 05:33 PM   #27
Junior Member
iTrader: (6)
 
Join Date: Dec 2008
Location: Boulder, CO
Posts: 291
Total Cats: 7
Default

A high-speed check valve or solenoid will obviously prevent siphoning from the tank during vacuum, but I was wondering if you needed individual check valves to prevent siphoning fluid between the nozzles?

I don't know what's worse - the check-valves not opening at the same time or the small delay caused by having to fill up the empty lines.

--Ferdi
ftjandra is offline   Reply With Quote
Old 11-13-2009, 06:33 PM   #28
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Delicious and Moist.
Posts: 26,323
Total Cats: 1,920
Default

Quote:
Originally Posted by JayL View Post
What's the consensus on the newer high pressure pumps that should improve atomization?
Got a link? I can't say that I know off-hand exactly which pumps you mean, unless you're talking about the ShurFlo-style units that DO has listed with higher-pressure limit switches.
Joe Perez is offline   Reply With Quote
Old 11-13-2009, 07:29 PM   #29
Elite Member
iTrader: (15)
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,889
Total Cats: 28
Default

Quote:
Originally Posted by ftjandra View Post
A high-speed check valve or solenoid will obviously prevent siphoning from the tank during vacuum, but I was wondering if you needed individual check valves to prevent siphoning fluid between the nozzles?

I don't know what's worse - the check-valves not opening at the same time or the small delay caused by having to fill up the empty lines.

--Ferdi
Good question. There could be a local pressure differential, such as when the valves open and close, that would cause siphoning. Two things though make me think it is not a big deal:
1. The pressure differential will probably be short lived, and also not that large, certainly nothing like the pressure differential caused by the pump. So the overall siphoning flow rates would be low. Plus at some point the water in the tubes would probably just oscillate back and forth and not actually leave the nozzle.
2. Even if the entire system downstream of the main check valve were evacuated, I do not think it would take very long at all to push out the air and recharge it with water once the pump turned on (or PWM valve opened, whatever). Air will push through the atomizing nozzles very quickly since it has a much lower viscosity. I am guessing a second or less. BUT even if it were significant, it would be easy to compensate for. For example, if you are triggering based on MAP, just set the turn-on point a little lower. That way the air is all gone well before you actually need the WI to prevent detonation.

In other words, I am not going to worry about it too much, and will only use one check valve. Hell just test it. Drain the system, turn on the pump, and see how long it takes before water sprays.
ZX-Tex is offline   Reply With Quote
Old 11-13-2009, 07:43 PM   #30
Junior Member
iTrader: (6)
 
Join Date: Dec 2008
Location: Boulder, CO
Posts: 291
Total Cats: 7
Default

Quote:
Originally Posted by ZX-Tex View Post
In other words, I am not going to worry about it too much, and will only use one check valve.
You mentioned that you were using an Aquamist high-speed valve - why the need for a check valve then?

--Ferdi
ftjandra is offline   Reply With Quote
Old 11-13-2009, 09:23 PM   #31
Elite Member
iTrader: (12)
 
Join Date: May 2007
Location: Austin, TX
Posts: 1,923
Total Cats: 0
Default

Quote:
Originally Posted by Joe Perez View Post
Got a link? I can't say that I know off-hand exactly which pumps you mean, unless you're talking about the ShurFlo-style units that DO has listed with higher-pressure limit switches.
Something like this.
JayL is offline   Reply With Quote
Old 11-13-2009, 11:36 PM   #32
Elite Member
iTrader: (15)
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,889
Total Cats: 28
Default

Quote:
Originally Posted by ftjandra View Post
You mentioned that you were using an Aquamist high-speed valve - why the need for a check valve then?

--Ferdi
You are right. No need for a check valve. I just used the term check valve since that is what most use. Not a lot of people are using an HSV.

Speaking of which I guess that means I will have an unused check valve if anyone needs one. Not that they are expensive.
ZX-Tex is offline   Reply With Quote
Old 11-14-2009, 12:34 AM   #33
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Delicious and Moist.
Posts: 26,323
Total Cats: 1,920
Default

Quote:
Originally Posted by JayL View Post
Something like this.
Ok, same as the DO 8031.
Joe Perez is offline   Reply With Quote
Old 11-14-2009, 12:40 AM   #34
Senior Member
iTrader: (6)
 
tyson87's Avatar
 
Join Date: Aug 2008
Location: West Palm Beach, FL
Posts: 1,023
Total Cats: 1
Default

my WI kit is going in tomorrow morning along with a dyno pull.
i am using the solenoid that is offered by DO with my MS controlling it.
tyson87 is offline   Reply With Quote
Old 11-14-2009, 12:46 AM   #35
Elite Member
iTrader: (15)
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,889
Total Cats: 28
Default

Quote:
Originally Posted by tyson87 View Post
i am using the solenoid that is offered by DO with my MS controlling it.
To do PWM? Or just to open/close the solenoid at the trigger point?
ZX-Tex is offline   Reply With Quote
Old 11-14-2009, 10:16 AM   #36
Senior Member
iTrader: (6)
 
tyson87's Avatar
 
Join Date: Aug 2008
Location: West Palm Beach, FL
Posts: 1,023
Total Cats: 1
Default

Quote:
Originally Posted by zx-tex View Post
to do pwm? Or just to open/close the solenoid at the trigger point?


pwm...
tyson87 is offline   Reply With Quote
Old 11-14-2009, 12:05 PM   #37
Elite Member
iTrader: (14)
 
Join Date: Mar 2006
Location: Edmonton, AB
Posts: 4,921
Total Cats: 0
Default

Doesn't the pump prime the lines when it is powered up?
jayc72 is offline   Reply With Quote
Old 11-14-2009, 12:36 PM   #38
Elite Member
iTrader: (15)
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,889
Total Cats: 28
Default

Quote:
Originally Posted by tyson87 View Post
pwm...
Are you sure that valve can handle PWM? I thought it was just intended as an on/off solenoid to act as a an alternative to a check valve (without the pressure drop).
ZX-Tex is offline   Reply With Quote
Old 11-14-2009, 02:36 PM   #39
Boost Pope
iTrader: (8)
 
Joe Perez's Avatar
 
Join Date: Sep 2005
Location: Delicious and Moist.
Posts: 26,323
Total Cats: 1,920
Default

Quote:
Originally Posted by ZX-Tex View Post
Are you sure that valve can handle PWM? I thought it was just intended as an on/off solenoid to act as a an alternative to a check valve (without the pressure drop).
The valve that DO sells appears to be the same Ingersoll unit that FM uses for their EBC. In that application, it seems to work somewhat linearly as a PWM proportional flow control valve. It will be interesting to see if it functions equally well with water.

Tyson, what frequency are you planning to drive it at?
Joe Perez is offline   Reply With Quote
Old 11-14-2009, 04:05 PM   #40
Elite Member
iTrader: (15)
 
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,889
Total Cats: 28
Default

Ahhh OK well maybe it will work then. I hope it does.
ZX-Tex is offline   Reply With Quote
 
 
Reply

Related Topics
Thread Thread Starter Forum Replies Last Post
Raleigh: Fiberglass headlight scope, 1.6L ECU, AFM, Hardtop latches, more bigmackloud Miata parts for sale/trade 13 09-22-2017 01:34 PM
Another Cast Manifold Corky Bell Prefabbed Turbo Kits 18 11-22-2016 10:01 PM
1994 Spec Miata Race Car SM/SM2/SSM For Sale Quinn Cars for sale/trade 6 10-23-2016 08:58 AM
Low oil pressure after 1.8 swap and new turbo setup JesseTheNoob DIY Turbo Discussion 15 09-30-2015 03:44 PM
NA Seat Sliders and Seat Belt Receivers skipstr Miata parts for sale/trade 2 09-28-2015 11:53 PM


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



All times are GMT -4. The time now is 04:46 AM.