I am fine taking mine without the hose and clamps. It isn't that I am in a hurry, but this is in stock locally.
M2Ken is offline  
Old 02-20-2017, 07:58 AM
  #102  
Elite Member
iTrader: (9)
 
TurboTim's Avatar
 
Join Date: Jun 2006
Location: Chesterfield, NJ
Posts: 6,898
Total Cats: 399
Default

Is there a counterbore for the o-ring to go into? From your pics, it looks like I can still see the Oring, and the hex portion of the ORB isn't bottomed out on your part.

If there's no counterbore, you're just tightening the oring against the spot face?
TurboTim is offline  
Old 02-20-2017, 08:53 AM
  #103  
Elite Member
iTrader: (8)
 
bahurd's Avatar
 
Join Date: Apr 2013
Posts: 2,381
Total Cats: 314
Default

Originally Posted by TurboTim
Is there a counterbore for the o-ring to go into? From your pics, it looks like I can still see the Oring, and the hex portion of the ORB isn't bottomed out on your part.

If there's no counterbore, you're just tightening the oring against the spot face?
I can see a c'bore. The o'ring isn't captured on the face + sides according to the SAE J1926 PORT dimensions but the c'bore provides a flat sealing face.


bahurd is offline  
Old 02-21-2017, 02:46 PM
  #104  
Former Vendor
Thread Starter
iTrader: (8)
 
TheBandit's Avatar
 
Join Date: Mar 2005
Location: Broken Arrow,Ok
Posts: 1,185
Total Cats: 57
Default

The O-ring will seal on the counterbore, which the drawing describes as a spotface. In this low pressure situation I didn't see the need in making the part significantly more expensive and machining the tight tolerance multi-angle bevel that is shown in the above drawing.

In other news, the first shipments will go out today!

If you followed us on FB you'd already know that.


TheBandit is offline  
Old 02-21-2017, 03:20 PM
  #105  
Junior Member
 
ChrisLol's Avatar
 
Join Date: Mar 2016
Location: Lexington, KY
Posts: 150
Total Cats: 75
Default

You would release these right after I searched and searched and searched and finally just cut/welded my factory piece.

Looks like another quality part from Hawley! Still enjoying my reroute spacer!
ChrisLol is offline  
Old 02-26-2017, 02:54 PM
  #106  
Junior Member
iTrader: (11)
 
mrryanbaker's Avatar
 
Join Date: Oct 2008
Location: Vancouver, WA
Posts: 164
Total Cats: 16
Default

Got mine yesterday. Looks awesome, can't wait to get it installed.
mrryanbaker is offline  
Old 02-27-2017, 09:13 AM
  #107  
Junior Member
 
Joseph Conley's Avatar
 
Join Date: Jan 2016
Location: Wadsworth, Ohio
Posts: 417
Total Cats: 67
Default

Fits like a charm. Don't mind the dirt.

Joseph Conley is offline  
Old 02-27-2017, 09:24 AM
  #108  
Elite Member
iTrader: (9)
 
TurboTim's Avatar
 
Join Date: Jun 2006
Location: Chesterfield, NJ
Posts: 6,898
Total Cats: 399
Default

Originally Posted by TheBandit
The O-ring will seal on the counterbore, which the drawing describes as a spotface. In this low pressure situation I didn't see the need in making the part significantly more expensive and machining the tight tolerance multi-angle bevel that is shown in the above drawing.
Fancy tapered official ORB geometry would indeed be expensive to reproduce. Standard square edge O-Ring counterbore would cost nothing more to do, using the tool that's already making your counterbore (spotface).

Our ORB machining for the same application (engine coolant) was initially done as you have made yours. Ultimately there were issues with it. There's many variables at play that affect how well that oring seals. You are relying on the end user to tighten the fitting to xx oring squish, and that the fitting doesn't rotate (not an issue with yours, is an issue if you use an AN fitting that also get's a hose screwed to the opposite end), and the variable squish of the oring changing with temps/age/coolant contamination. The only thing keeping the oring from expanding and ultimately splitting is it's press between two theoretically parallel surfaces. Coolant is slippery. Aluminum expands when warm. Engine vibrates a lot. Spraying coolant on the track/road is not ideal.

Creating a simple Oring c'bore solves all of this and costs nothing extra. Well maybe adding a 45° chamfer/oring lead to the c'bore with your spot face tool but your edge breaks look nice after the tumbling.

Last edited by TurboTim; 02-27-2017 at 09:35 AM.
TurboTim is offline  
Old 03-02-2017, 08:23 AM
  #109  
Former Vendor
Thread Starter
iTrader: (8)
 
TheBandit's Avatar
 
Join Date: Mar 2005
Location: Broken Arrow,Ok
Posts: 1,185
Total Cats: 57
Default

Thanks for the overwhelming interest in these parts. We're working to get another batch in as soon as our machine shop can pop them out. Shooting for 1-2 weeks, but I should have a more concrete eta by the end of the week.
TheBandit is offline  
Old 03-07-2017, 12:30 PM
  #110  
Elite Member
iTrader: (4)
 
psyber_0ptix's Avatar
 
Join Date: Mar 2012
Location: Northern VA
Posts: 4,648
Total Cats: 544
Default

I'm a bit worried this won't clear my A/C belt tensioner :(
psyber_0ptix is offline  
Old 03-07-2017, 01:10 PM
  #111  
Junior Member
iTrader: (4)
 
julio's Avatar
 
Join Date: Oct 2012
Posts: 130
Total Cats: 23
Default

I almost ordered one too but looking at the pics wasn't sure it would work with AC. Curious......
julio is offline  
Old 03-07-2017, 01:26 PM
  #112  
Newb
 
adam crane's Avatar
 
Join Date: Feb 2017
Posts: 7
Total Cats: 0
Default

Please count me in for one, with radiator hose in your next batch. Provided it's been confirmed to clear an NB with AC
adam crane is offline  
Old 03-07-2017, 02:09 PM
  #113  
Elite Member
iTrader: (4)
 
psyber_0ptix's Avatar
 
Join Date: Mar 2012
Location: Northern VA
Posts: 4,648
Total Cats: 544
Default




For me, it'd undoubtedly hit the frame of the tensioner. I could just flip it and run it like standard, but that defeats the purpose as my stocker is doing just fine otherwise.

I may post mine up for sale if anyone wants it sooner than the next batch.
psyber_0ptix is offline  
Old 03-07-2017, 04:26 PM
  #114  
Newb
 
adam crane's Avatar
 
Join Date: Feb 2017
Posts: 7
Total Cats: 0
Default

Originally Posted by psyber_0ptix



For me, it'd undoubtedly hit the frame of the tensioner. I could just flip it and run it like standard, but that defeats the purpose as my stocker is doing just fine otherwise.

I may post mine up for sale if anyone wants it sooner than the next batch.
so you're saying it won't clear your AC pully?
adam crane is offline  
Old 03-07-2017, 04:28 PM
  #115  
Elite Member
iTrader: (4)
 
psyber_0ptix's Avatar
 
Join Date: Mar 2012
Location: Northern VA
Posts: 4,648
Total Cats: 544
Default

It won't clear the belt tensioner. The A/C compressor isn't hooked up in the picture, but you can see that the outlet would pass right up against the metal bracket of the tensioner and may even interfere directly with the pulley on the tensioner.
psyber_0ptix is offline  
Old 03-08-2017, 08:48 PM
  #116  
Newb
 
2798jmitch's Avatar
 
Join Date: Feb 2017
Location: maryland
Posts: 21
Total Cats: 0
Default

great idea! will be interested when my cars back together and i have money again haha
2798jmitch is offline  
Old 03-09-2017, 09:31 AM
  #117  
Former Vendor
Thread Starter
iTrader: (8)
 
TheBandit's Avatar
 
Join Date: Mar 2005
Location: Broken Arrow,Ok
Posts: 1,185
Total Cats: 57
Default

Originally Posted by psyber_0ptix
It won't clear the belt tensioner. The A/C compressor isn't hooked up in the picture, but you can see that the outlet would pass right up against the metal bracket of the tensioner and may even interfere directly with the pulley on the tensioner.
Psyber - Sorry about the fitment issue. I probably should have noted something about fitment with accessories. None of our cars still have A/C so I didn't give it a second thought.

If you'd rather return it, just let me know.
TheBandit is offline  
Old 03-09-2017, 09:47 AM
  #118  
Elite Member
iTrader: (4)
 
psyber_0ptix's Avatar
 
Join Date: Mar 2012
Location: Northern VA
Posts: 4,648
Total Cats: 544
Default

I am pretty stubborn and haven't given up A/C because DC area is a swamp.

I'll pm you later today
psyber_0ptix is offline  
Old 03-09-2017, 09:52 AM
  #119  
Elite Member
iTrader: (8)
 
bahurd's Avatar
 
Join Date: Apr 2013
Posts: 2,381
Total Cats: 314
Default

My car has no A/C or PWR Steering either. Maybe a version, change to have the -16 ORB coming out 90 degrees to the current design would do both.
bahurd is offline  
Old 08-15-2017, 08:28 AM
  #120  
Former Vendor
Thread Starter
iTrader: (8)
 
TheBandit's Avatar
 
Join Date: Mar 2005
Location: Broken Arrow,Ok
Posts: 1,185
Total Cats: 57
Default

Just as a reminder, we do have these inlets in stock with hoses and fittings!

https://squareup.com/store/hawleyper...r-pump-inlet-1
TheBandit is offline  