Prefabbed Turbo Kits A place to discuss prefabricated turbo kits on the market

Summary of latest turbo stud mounting recommendations?

Thread Tools
 
Search this Thread
 
Old 02-19-2015, 06:51 PM
  #41  
Elite Member
 
bbundy's Avatar
 
Join Date: Jul 2005
Location: Anacortes, WA
Posts: 2,478
Total Cats: 144
Default

Originally Posted by JasonC SBB
Did you chamfer the entrance of the manifold holes? Did you torque the studs in? What tool did you use?
The holes were countersunk down about 1/2" below the face of the flange. Threads had helicoils in them due to repeated repairs and buggered threads from broken off studs being drilled out and heat barbequing the mild steel threads. My diy manifold allows the thread holes to be extra deep. The first set of studs I got from BEGI were about 1/2" longer than the ones from track speed. They were not bottomed out in the holes as Corky suggests but they were double nutted and torqued in place. Also drilled and tapped small set screw holes in the flange 90 degrees to each stud. Set screws won’t allow studs to turn out.

Second set were from Track speed installed as Andrew said other than using helicoils in the holes before even using it for the first time on the car and they also have been entirely trouble free for over a year.

The material in the helecoils seems to hold up better to the heat for the threads cut in my mild steel flange. McMaster sells High temp nickel helicoils. In 10 and 15mm lengths. Bout the only thing I can say is they seem to work for me with my setup.
McMaster-Carr
bbundy is offline  
Leave a poscat 0 Leave a negcat
Old 02-19-2015, 08:01 PM
  #42  
Senior Member
 
timk's Avatar
 
Join Date: Dec 2004
Location: Brisbane, Australia
Posts: 1,278
Total Cats: 37
Default

Originally Posted by timk
Can I do any harm by tack welding the Inconel studs onto the manifold? On the non-face side obviously.
C'mon bitches you missed my important question because of all your girlyfightingwords!
timk is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 01:31 AM
  #43  
Elite Member
Thread Starter
 
JasonC SBB's Avatar
 
Join Date: Jul 2005
Posts: 6,420
Total Cats: 84
Default

Originally Posted by Savington
I'm not ignoring this question, but I am choosing not to answer it. My recommendation is that you purchase our kit and install it exactly as the instructions say to. If you want to DIY it, that's fine, but I don't think anyone here will expect me to assist you with that particular endeavor.
If you sold an M8 kit, I'd have bought 'em already.
JasonC SBB is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 01:35 AM
  #44  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

There is an m8 prototype. EO2K has them. Message Andrew about it.
aidandj is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 01:41 AM
  #45  
Elite Member
Thread Starter
 
JasonC SBB's Avatar
 
Join Date: Jul 2005
Posts: 6,420
Total Cats: 84
Default

Too late. I have M8's from FM years ago.
JasonC SBB is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 03:56 PM
  #46  
Elite Member
iTrader: (16)
 
patsmx5's Avatar
 
Join Date: Aug 2007
Location: Houston, TX
Posts: 9,297
Total Cats: 477
Default

Originally Posted by JasonC SBB
I guess that means you've tried it and it didn't work, eh?

The next question, is, with Resbond, is it necessary to torque the studs down?
Maybe not? Why NOT torque them a bit, to say, 10-15 ft*lbs?
patsmx5 is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 05:47 PM
  #47  
Elite Member
 
bbundy's Avatar
 
Join Date: Jul 2005
Location: Anacortes, WA
Posts: 2,478
Total Cats: 144
Default

Originally Posted by timk
C'mon bitches you missed my important question because of all your girlyfightingwords!
Try it and post your results. I doubt anybody has welded in inconel studs.
bbundy is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 05:48 PM
  #48  
SADFab Destructive Testing Engineer
iTrader: (5)
 
aidandj's Avatar
 
Join Date: Apr 2014
Location: Beaverton, USA
Posts: 18,642
Total Cats: 1,866
Default

Either way find the right filler.
aidandj is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 06:49 PM
  #49  
Elite Member
Thread Starter
 
JasonC SBB's Avatar
 
Join Date: Jul 2005
Posts: 6,420
Total Cats: 84
Default

Originally Posted by patsmx5
Maybe not? Why NOT torque them a bit, to say, 10-15 ft*lbs?
That's what I'm leaning towards. 30 ft-lbs seems a lot for M8's.
JasonC SBB is offline  
Leave a poscat 0 Leave a negcat
Old 02-20-2015, 10:29 PM
  #50  
Elite Member
 
nitrodann's Avatar
 
Join Date: Apr 2010
Location: Newcastle, Australia
Posts: 2,826
Total Cats: 67
Default

Originally Posted by timk
C'mon bitches you missed my important question because of all your girlyfightingwords!
I stock resbond so I dont typically do this but I have done it on manifolds which have had very poor damaged threads, its held up no trouble, TIG'd with 308L wire.

Dann
nitrodann is offline  
Leave a poscat 0 Leave a negcat
Old 02-21-2015, 03:26 AM
  #51  
Senior Member
 
timk's Avatar
 
Join Date: Dec 2004
Location: Brisbane, Australia
Posts: 1,278
Total Cats: 37
Default

Thanks Dann I'll try the Resbond again first. I might have to hit you up for a bottle!

Cheers
timk is offline  
Leave a poscat 0 Leave a negcat
Old 02-22-2015, 09:27 AM
  #52  
Senior Member
iTrader: (9)
 
Rallas's Avatar
 
Join Date: Oct 2006
Location: Lexington SC
Posts: 1,176
Total Cats: 35
Default

I tigged one 8 mm FM in Inconel stud to a nut on my MSM turbo with L309 filer. Not structural, just three small tacks.
FM seems to be only real Inconel 8 mm option. They are pricey too considering no resbond and only 8 mm studs. The Trackspeed 10 mm are not bad at $155. If they made 8 mm I would have gone Trackspeed in a heartbeat.

I still want to try the Nissan 8 mm studs on my downpipe to turbo connection.
Rallas is offline  
Leave a poscat 0 Leave a negcat
Old 02-23-2015, 05:07 PM
  #53  
Supporting Vendor
iTrader: (3)
 
ThePass's Avatar
 
Join Date: Jul 2006
Location: San Diego
Posts: 3,303
Total Cats: 1,216
Default

Originally Posted by sixshooter
This is what I use in case anyone is interested:
The points others have brought up about those studs and nuts aside, I've personally had those nord-lock washers fail completely when I tried them.

-Ryan
__________________
Ryan Passey
ThePass is offline  
Leave a poscat 0 Leave a negcat
Old 02-23-2015, 05:25 PM
  #54  
Elite Member
iTrader: (2)
 
fooger03's Avatar
 
Join Date: Jan 2009
Location: Columbus, OH
Posts: 4,140
Total Cats: 229
Default

Nordlocks have failed on my street car.
fooger03 is offline  
Leave a poscat 0 Leave a negcat
Old 02-23-2015, 06:06 PM
  #55  
Elite Member
 
bbundy's Avatar
 
Join Date: Jul 2005
Location: Anacortes, WA
Posts: 2,478
Total Cats: 144
Default

how did the nordlocks fail?
I've never had them fail. They did not make non Inconel studs work at all, nothing did, but I've never had them fail by themselves.

Inconel studs nordlock and resbond worked for me as did inconel studs stage 8 and resbond. Both with helicoiled stud holes in a mild steel manifold.

I've had the AN hardened high strenght nuts fail miserbly as they shattered into pieces.

Last edited by bbundy; 02-23-2015 at 07:42 PM.
bbundy is offline  
Leave a poscat 0 Leave a negcat
Old 02-23-2015, 08:13 PM
  #56  
Elite Member
iTrader: (2)
 
fooger03's Avatar
 
Join Date: Jan 2009
Location: Columbus, OH
Posts: 4,140
Total Cats: 229
Default

2x manifold studs backed out until they hit the manifold. 3x other nuts were loose on the studs.
fooger03 is offline  
Leave a poscat 0 Leave a negcat
Old 02-23-2015, 08:38 PM
  #57  
Elite Member
 
codrus's Avatar
 
Join Date: Mar 2007
Location: Santa Clara, CA
Posts: 5,167
Total Cats: 856
Default

Originally Posted by fooger03
2x manifold studs backed out until they hit the manifold. 3x other nuts were loose on the studs.
With inconels, or SS studs?

--Ian
codrus is offline  
Leave a poscat 0 Leave a negcat
Old 02-23-2015, 09:50 PM
  #58  
Elite Member
iTrader: (2)
 
fooger03's Avatar
 
Join Date: Jan 2009
Location: Columbus, OH
Posts: 4,140
Total Cats: 229
Default

not inconels.

I had inconels ready to go in, but the shop that rebuilt my engine is a piece of **** - didn't install with the thread pitch I told them to install.

****, just realized these were manifold to block studs, not turbo to manifold studs. My post above is not relevant to this thread.
fooger03 is offline  
Leave a poscat 0 Leave a negcat
Old 02-24-2015, 01:42 AM
  #59  
Former Vendor
iTrader: (31)
 
Savington's Avatar
 
Join Date: Nov 2006
Location: Sunnyvale, CA
Posts: 15,442
Total Cats: 2,100
Default

If you are seeing failures on the manifold/head hardware, your manifold is warped. The OEM hardware should work on every application (street to full race).
Savington is offline  
Leave a poscat 0 Leave a negcat
Old 02-24-2015, 09:03 AM
  #60  
VladiTuned
iTrader: (76)
 
18psi's Avatar
 
Join Date: Apr 2008
Posts: 35,821
Total Cats: 3,481
Default

Full Race, you say?
18psi is offline  
Leave a poscat 0 Leave a negcat


Quick Reply: Summary of latest turbo stud mounting recommendations?



All times are GMT -4. The time now is 02:47 AM.