well it seems like nothing ever goes my way, well i have a Innovative LC-1 Wideband with sqaure guage.......
my problem is that my reading's are never between 10.1 and 20.4, i even adjusted the fuel to see if at idle it would read something else..... no it either reads 10.1 or 20.4 and it will sometimes jump up and down that it, it does the same with the guage and on the megasquirt......
WHat do ya'll think ?
well it seems like nothing ever goes my way, well i have a Innovative LC-1 Wideband with sqaure guage.......
my problem is that my reading's are never between 10.1 and 20.4, i even adjusted the fuel to see if at idle it would read something else..... no it either reads 10.1 or 20.4 and it will sometimes jump up and down that it, it does the same with the guage and on the megasquirt......
WHat do ya'll think ?
#9
Elite Member
iTrader: (15)
Join Date: Dec 2007
Location: San Antonio, Texas
Posts: 4,847
Total Cats: 27
I have the LC-1 and the MS, gauge, and MLV all agree very closely, like within 0.1-0.2 AFR.
What I did:
1. Check to be sure the MSQ is set for Innovate LC-1 default ( 0-5V 0.5-1.5 lambda) using the configurator in Megatune
2. The analog out on the LC-1 connected to the MS should be set like above 0-5V = 0.5 - 1.5 lambda
3. Set the analog out one the LC-1 connected to your gauge to the settings required for that gauge (check the manual for the gauge).
4. Make sure megalogviewer is set for Innovate LC-1 Default
Once you do all this they should agree very closely. If not then you probably have a ground offset issue. Like Brain said they should all be grounded to the same spot.
What I did:
1. Check to be sure the MSQ is set for Innovate LC-1 default ( 0-5V 0.5-1.5 lambda) using the configurator in Megatune
2. The analog out on the LC-1 connected to the MS should be set like above 0-5V = 0.5 - 1.5 lambda
3. Set the analog out one the LC-1 connected to your gauge to the settings required for that gauge (check the manual for the gauge).
4. Make sure megalogviewer is set for Innovate LC-1 Default
Once you do all this they should agree very closely. If not then you probably have a ground offset issue. Like Brain said they should all be grounded to the same spot.