Flex sensor, ms3x not reading anything?
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
Car is at the shop, it's getting ready for the dyno, I'm currently away taking care of my gf for an operation and they say the flex sensor reads nothing.
I'm sure I verified continuity to the signal and flex sensor input on the db37.
Aside from enabling in MS, is there anything else that has to be done? Resistor is handled internally already?
I'm sure I verified continuity to the signal and flex sensor input on the db37.
Aside from enabling in MS, is there anything else that has to be done? Resistor is handled internally already?
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
I'm really honestly lame with megasquirt. Adding wires is all I can really do. I didn't have it enabled otherwise and didn't know how to test for things.
I'm away from my laptop sitting in a preop waiting room, I'll see if I can find a semi recent tune in email
I'm away from my laptop sitting in a preop waiting room, I'll see if I can find a semi recent tune in email
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
Yea it's that gut feeling validated and feeling helpless being afar.
I think it just doesn't register anything as far as I've been told. Sensor is grounded directly to the head at the same point as ecu, power and signal is connected to the unused "purge valve" wiring to the ecu.
Right now if it can't be figured out, they will touch up the 93oct tune, drain the tank and save a separate file for e85 tune.
Then when I can figure out the wiring, I'll bring it back and they can merge the two and put it on the dyno for any blending.
Still moving forward even if it has to be temporarily e85 only.
I think it just doesn't register anything as far as I've been told. Sensor is grounded directly to the head at the same point as ecu, power and signal is connected to the unused "purge valve" wiring to the ecu.
Right now if it can't be figured out, they will touch up the 93oct tune, drain the tank and save a separate file for e85 tune.
Then when I can figure out the wiring, I'll bring it back and they can merge the two and put it on the dyno for any blending.
Still moving forward even if it has to be temporarily e85 only.
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
I also have a second flex sensor on the fuel system from the Innovate ecf-1 gauge that ended up being defective and sent out for warranty. I made a suggestion to switch the plugs in case it's the sensor itself.
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
Megasquirt Support Forum (MSEXTRA) ? MS3pro Flex Fuel NO SIGNAL (View topic)
From basic on phone googlefu, I found the above thread. I know it's for pro, but wonder if it's the same issue.
Does it matter that I used 12V? Matt also recommended not grounding at the head but onto sensor ground at squirt.
Was there anything on my end that still required some use of a resistor? I thought I read that power didn't have to be 5v
From basic on phone googlefu, I found the above thread. I know it's for pro, but wonder if it's the same issue.
Does it matter that I used 12V? Matt also recommended not grounding at the head but onto sensor ground at squirt.
Was there anything on my end that still required some use of a resistor? I thought I read that power didn't have to be 5v
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
https://www.miataturbo.net/megasquir...2/#post1341625
Seems I have mine wired very similar to the above, so aside from miswiring or continuity break, I'm not sure what can change. Unless it's something within megasquirt that needs to be done.
Thread Starter
Elite Member
iTrader: (4)
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
OK so I just got in, replaced the o2 sensor in the parking lot since it threw an e8 code. This is the third sensor in two months. Added the hbx-1 heatsink. Hoping it will last a tiny bit longer.
The sensor gets power and has good ground. The continuity in the signal failed on the ecu harness. From sensor pin to ecu plug is fine. Just the pin on the adapter harness isn't connecting. Both sides of the pin pass the beep test so I'm at a loss, I just cut the wires and jumped it outside the ecu plug/adapter harness just to get the dyno time back on the table.
Edit: sad panda, have to reschedule because they loaded another car up.
On the plus, everything works now for real. Oh well, no numbers for another 3 weeks.
The sensor gets power and has good ground. The continuity in the signal failed on the ecu harness. From sensor pin to ecu plug is fine. Just the pin on the adapter harness isn't connecting. Both sides of the pin pass the beep test so I'm at a loss, I just cut the wires and jumped it outside the ecu plug/adapter harness just to get the dyno time back on the table.
Edit: sad panda, have to reschedule because they loaded another car up.
On the plus, everything works now for real. Oh well, no numbers for another 3 weeks.
Last edited by psyber_0ptix; Apr 29, 2017 at 12:47 PM.