Notices
Miata parts for sale/trade Buy, trade or sell your Miata parts here.

Coolant Block-Off and Reroute Spacer // EGR Block-Off // EGR Block-Off with FPR Mount

Thread Tools
 
Search this Thread
 
Old Jan 23, 2017 | 05:45 AM
  #101  
yossi126's Avatar
Senior Member
iTrader: (6)
 
Joined: Sep 2013
Posts: 901
Total Cats: -13
Default

Don't know what this guy did wrong, but his hose sits way too close to the intake. Mine clears the intake elbow just enough and I'm with a 53 mm mishimoto and bent brackets.
Old Jan 23, 2017 | 08:21 AM
  #102  
TheBandit's Avatar
Thread Starter
Former Vendor
iTrader: (8)
 
Joined: Mar 2005
Posts: 1,185
Total Cats: 57
From: Broken Arrow,Ok
Default

We've found that for N/A applications there shouldn't be any issue running the included hose. For those with turbo applications it is sometimes required to cut the radiator end a little differently or splice in another hose to gain clearance for the IC tubing. I'm hoping I get some time to work on a more elegant solution to this in the sometime this year.
Old Jan 28, 2017 | 06:41 PM
  #103  
Gimpster's Avatar
Junior Member
 
Joined: Aug 2016
Posts: 65
Total Cats: 7
From: Miami Beach, FL
Default

Well, here is what it looks like installed on my NA8. Sorry for the bad pictures, good as I could get my camera into some tight spots. I was lucky in that I was also doing clutch/flywheel so I could tip my motor forward to install vs. try to shove my fat hands behind there.





I found it worked best if I threaded the hose UNDER the engine harness and behind the clutch line. I also massaged the fuel feed and return hoses to get the hose to "lay down".



Because of the oil cooler water hose outlet there, you can only get the clamp so far back.. I kept pushing thinking, why isn't this going?

Old Jan 28, 2017 | 06:44 PM
  #104  
Gimpster's Avatar
Junior Member
 
Joined: Aug 2016
Posts: 65
Total Cats: 7
From: Miami Beach, FL
Default

Oh, and you might find this "interesting" but I designed a little slide/snap in piece for the upper timing cover and printed it on my 3d printer in in black ABS. I'll fix a few issues with it and put it on Thingiverse if anyone else wants to print one.
Old Mar 1, 2017 | 08:07 PM
  #105  
LownSlow616's Avatar
Senior Member
 
Joined: May 2015
Posts: 514
Total Cats: -10
From: Grand Rapids, MI
Default

Sent email but no reply. Regarding the reroute spacer-- there are 3 threaded holes in it. One is used by the factory coolant temp sensor. What size are the threads in the other 2 holes?
Old Mar 2, 2017 | 04:36 AM
  #106  
TheBlack7's Avatar
Junior Member
 
Joined: Jan 2017
Posts: 58
Total Cats: 3
From: Marysville, Ohio
Default

Just made my order for a reroute! Can't wait
Old Mar 2, 2017 | 08:16 AM
  #107  
TheBandit's Avatar
Thread Starter
Former Vendor
iTrader: (8)
 
Joined: Mar 2005
Posts: 1,185
Total Cats: 57
From: Broken Arrow,Ok
Default

Originally Posted by LownSlow616
Sent email but no reply. Regarding the reroute spacer-- there are 3 threaded holes in it. One is used by the factory coolant temp sensor. What size are the threads in the other 2 holes?
We get a lot of email everyday, and we make our best effort to reply to all of them but that doesn't mean one gets missed once in a while. My apologies if that's the case.

One hole is for the hose nipple that connects to the heater core and the other is for use with gauges or whatever you choose to do with it. If you'd rather not use this port, just grab a 3/8" NPT plug to seal off this port.
Old Mar 2, 2017 | 09:35 AM
  #108  
LownSlow616's Avatar
Senior Member
 
Joined: May 2015
Posts: 514
Total Cats: -10
From: Grand Rapids, MI
Default

Originally Posted by TheBandit
We get a lot of email everyday, and we make our best effort to reply to all of them but that doesn't mean one gets missed once in a while. My apologies if that's the case.

One hole is for the hose nipple that connects to the heater core and the other is for use with gauges or whatever you choose to do with it. If you'd rather not use this port, just grab a 3/8" NPT plug to seal off this port.
What size threads in the heater core fitting hole? I want to use a different fitting than the provided one
Old Mar 2, 2017 | 10:16 AM
  #109  
TheBandit's Avatar
Thread Starter
Former Vendor
iTrader: (8)
 
Joined: Mar 2005
Posts: 1,185
Total Cats: 57
From: Broken Arrow,Ok
Default

Originally Posted by LownSlow616
What size threads in the heater core fitting hole? I want to use a different fitting than the provided one
It is also a 3/8" NPT.
Old Mar 2, 2017 | 05:04 PM
  #110  
Shibby's Avatar
Junior Member
iTrader: (4)
 
Joined: Oct 2006
Posts: 230
Total Cats: 39
From: Hagerstown, MD
Default

The uppermost hole on the spacer is much smaller than the two on the sides. Can you double check the necessary plug size? I'd do it myself, but I have the spacer mounted on the head already.

Thanks!
Old Mar 2, 2017 | 05:31 PM
  #111  
TheBandit's Avatar
Thread Starter
Former Vendor
iTrader: (8)
 
Joined: Mar 2005
Posts: 1,185
Total Cats: 57
From: Broken Arrow,Ok
Default

Originally Posted by Shibby
The uppermost hole on the spacer is much smaller than the two on the sides. Can you double check the necessary plug size? I'd do it myself, but I have the spacer mounted on the head already.

Thanks!
Shot from the hip and missed.

It's a 1/8 NPT hole. My apologies.
Old Mar 5, 2017 | 11:36 AM
  #112  
LownSlow616's Avatar
Senior Member
 
Joined: May 2015
Posts: 514
Total Cats: -10
From: Grand Rapids, MI
Default

Is the 30.25mm freeze plug the right size for a '99 head? Barely took any force to get it flush with the head. Couple taps with a hammer and it was "in" Felt like I could've pressed it in with my hands

Edit: never installed a freeze plug before. Is it supposed to be that easy?
Old Mar 5, 2017 | 01:24 PM
  #113  
Bronson M's Avatar
Senior Member
iTrader: (1)
 
Joined: Feb 2015
Posts: 1,109
Total Cats: 220
Default

The hole might be larger on the BP4W, my first attempt at running just a plug without a plate ended with a "pop" and a shower of coolant.
Old Mar 6, 2017 | 08:23 AM
  #114  
TheBandit's Avatar
Thread Starter
Former Vendor
iTrader: (8)
 
Joined: Mar 2005
Posts: 1,185
Total Cats: 57
From: Broken Arrow,Ok
Default

Originally Posted by LownSlow616
Is the 30.25mm freeze plug the right size for a '99 head? Barely took any force to get it flush with the head. Couple taps with a hammer and it was "in" Felt like I could've pressed it in with my hands

Edit: never installed a freeze plug before. Is it supposed to be that easy?
I haven't experienced a situation where it didn't seal, but if you're worried about it throw a gasket or some rtv between the plate and the head.

I definitely would not recommend running the plug without a plate to secure it. It's very cheap insurance at that point.
Old Mar 6, 2017 | 09:43 AM
  #115  
Gimpster's Avatar
Junior Member
 
Joined: Aug 2016
Posts: 65
Total Cats: 7
From: Miami Beach, FL
Default

I used good ole Indian Head shellac on my plug (I posted the Dorman # earlier for the brass model), because that's how I was taught long long ago by my old man :P I then put anaerobic sealant around the plate for *****.
Old Mar 19, 2017 | 12:07 PM
  #116  
Shibby's Avatar
Junior Member
iTrader: (4)
 
Joined: Oct 2006
Posts: 230
Total Cats: 39
From: Hagerstown, MD
Default

Originally Posted by TheBandit
Thanks for the feedback! Sometimes geometry is a funny thing and often times we run into the whole 10lbs of stuff in a 5lb bag, which is the case here. I tried to give as much clearance as I could while not making the part anymore difficult to machine and thus keeping the price at a very economical level.
Agree with rigidbigelsworth. Something should really be done about the spacing between the sensor and heater core nipple. Is extremely difficult/frustrating to try to make them play nicely together. Couldn't you swap the location of the large and small sensor ports?

For anyone doing this going forward, install as many hoses on the head as you can before putting the head/motor back in the car.

That being said, everything else is top notch! Pleasure doing business with you.
Old Mar 19, 2017 | 08:15 PM
  #117  
LownSlow616's Avatar
Senior Member
 
Joined: May 2015
Posts: 514
Total Cats: -10
From: Grand Rapids, MI
Default

Torque spec on the reroute spacer/thermostat housing bolts?
Old Mar 19, 2017 | 08:37 PM
  #118  
bahurd's Avatar
Elite Member
iTrader: (8)
 
Joined: Apr 2013
Posts: 2,408
Total Cats: 316
Default

Originally Posted by LownSlow616
Torque spec on the reroute spacer/thermostat housing bolts?
Why would it be different than stock? Same bolt thread.

https://sites.google.com/a/philb.us/...engine-cooling
Old Apr 5, 2017 | 05:04 PM
  #119  
TheBandit's Avatar
Thread Starter
Former Vendor
iTrader: (8)
 
Joined: Mar 2005
Posts: 1,185
Total Cats: 57
From: Broken Arrow,Ok
Thumbs up

We're continuing to add some new products. This one is a slight spin off an existing product, but has been requested by several customers.

Introducing the EGR Nipple Block-Off

Need an additional vacuum source, or possibly a shorter and cleaner routing to parts near the firewall like a FPR? This should help you out!


Old Apr 5, 2017 | 08:01 PM
  #120  
psyber_0ptix's Avatar
Elite Member
iTrader: (4)
 
Joined: Mar 2012
Posts: 4,648
Total Cats: 544
From: Northern VA
Default

YAS. is it an NPT fitting? One can use a 90° barb and a quick elbow of a vacuum line right to theFPR mounted on a Hawley Performance EGR/FPR mount. So clean.



All times are GMT -4. The time now is 01:02 AM.