MS3 EGT settings problem. Can't use a value less then -40
#1
Junior Member
Thread Starter
iTrader: (1)
Join Date: Jan 2009
Location: Bradenton, FL
Posts: 290
Total Cats: 5
MS3 EGT settings problem. Can't use a value less then -40
I'm running a digital analog faced AEM EGT gauge (30-5131). My problem is AEM thought it would be cool to make 0.5v = 0 degrees F and 4.5v = 1800 degrees F. That gives a formula of 450 * V - 225 = EGT Temp. Well at 0.0v that gives a value of -225. Tunerstudio won't let me input a value under -40. Is there work around for this or am I screwed? In the mean time I'm using a generic sensor input, which lets me input -225, to be able to log EGT but would like to use the built in safety system if I could.
HELP!
HELP!
#5
Supporting Vendor
iTrader: (33)
Join Date: Jul 2006
Location: atlanta-ish
Posts: 12,659
Total Cats: 134
I'm running a digital analog faced AEM EGT gauge (30-5131). My problem is AEM thought it would be cool to make 0.5v = 0 degrees F and 4.5v = 1800 degrees F. That gives a formula of 450 * V - 225 = EGT Temp. Well at 0.0v that gives a value of -225. Tunerstudio won't let me input a value under -40. Is there work around for this or am I screwed? In the mean time I'm using a generic sensor input, which lets me input -225, to be able to log EGT but would like to use the built in safety system if I could.
HELP!
HELP!
450V -225 = -40
450V = 185
V = .41
-40° = .41v
#10
Junior Member
Thread Starter
iTrader: (1)
Join Date: Jan 2009
Location: Bradenton, FL
Posts: 290
Total Cats: 5
Spoke too soon... It lets me put in a value of -225 now but now it constantly shows EGT as -100. Switch back to using generic inputs and it will display fine.... What went wrong? Added my .msq for gigs.