Prefabbed Turbo Kits A place to discuss prefabricated turbo kits on the market

Need Help Fast, Anyone With A Greddy!!!!

Thread Tools
 
Search this Thread
 
Old 07-27-2006, 11:34 PM
  #1  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default Need Help Fast, Anyone With A Greddy!!!!

Which Fuel Line Am I Unplugging From The Fuel Rail And Into The Fpr? The One Towards The Rear Of The Car (green) Or The Front Of The Car (red)?
Attached Images
File Type: jpg
IMGA2516.JPG (52.4 KB, 39 views)
 
Old 07-27-2006, 11:36 PM
  #2  
Junior Member
iTrader: (1)
 
BrokeEnthusiast's Avatar
 
Join Date: Feb 2006
Location: Nashville, TN
Posts: 406
Total Cats: 0
Default

green arrow, but not from that location, do it from the hard line
BrokeEnthusiast is offline  
Old 07-27-2006, 11:38 PM
  #3  
Junior Member
iTrader: (1)
 
BrokeEnthusiast's Avatar
 
Join Date: Feb 2006
Location: Nashville, TN
Posts: 406
Total Cats: 0
Default

wait itlooks like you already have one pulged into the FPR, which is it the feed or return?
BrokeEnthusiast is offline  
Old 07-27-2006, 11:57 PM
  #4  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

SO FAR I'VE GOT A PRETTY FUCKED UP fpr SITUATION.......

ONE OF MY MANAGERS THAT HELPED ME WITH THE INSTALL HOOKED IT UP BY HIMSELF AND I DIDN'T CHECK IT....SOOOOOO THE RETURN LINE WAS GOING INTO THE OUTLET AND THE INLET ON THE FPR HAD THE HOSE GOING TO THE FUEL RAIL (RED ARROW) COMPLETELY *** BACKWARDS.....SO WHEN I REALIZED THE INLET/OUTLET WERE SWITCHED I SWITCHED THEM....RUNNING A LIL BETTER, BUT NOT MUCH.....NOW I'VE GOT THE LINE COMING FROM THE BLUE ARROW GOING INTO THE INLET OF THE FPR AND THE LINE FROM THE OUTLET IS GOING WHERE THE GREEN ARROW IS POINTING....AM I GOOD NOW?

(BLUE ARROW GOING INTO THE INLET......OUTLET GOING TO GREEN ARROW...RIGHT?)
Attached Images
File Type: jpg
IMGA2516.JPG (52.6 KB, 16 views)
 
Old 07-28-2006, 12:03 AM
  #5  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

And The Outlet (going To The Rail) Is The Fitting In The Center.....right?
 
Old 07-28-2006, 12:34 AM
  #6  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

I Think I've Still Got This Messed Up......i've Got Point 1 Going To The Offset Fitting And Point 2 Is Connected To The Center Fitting......it Needs To Be The Other Way Around..correct?
Attached Images
File Type: jpg
IMGA2517.JPG (51.9 KB, 18 views)
 
Old 07-28-2006, 01:10 AM
  #7  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

Anyone!?!?!?!?!?!?!?!?!?!?
 
Old 07-28-2006, 02:47 AM
  #8  
:(
iTrader: (7)
 
magnamx-5's Avatar
 
Join Date: Jul 2006
Location: nowhere
Posts: 8,255
Total Cats: 4
Default

the line that comes out by your stock fpr is the return i just checked mine.
magnamx-5 is offline  
Old 07-28-2006, 02:50 AM
  #9  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

This is how it's set up now........the line coming from point one in the last picture is in the center fitting and the line from point two is going into the side/offset fitting........is this correct?

Thanks
 
Old 07-28-2006, 02:54 AM
  #10  
:(
iTrader: (7)
 
magnamx-5's Avatar
 
Join Date: Jul 2006
Location: nowhere
Posts: 8,255
Total Cats: 4
Default

it shouldn't matter i have mine hooked up backwards from that but it isn't a vortech it is an obx the fpr creates a restriction no matter what so the entrance exit doesn't matter. why do you always post at such a late hour and make us go outside and look at our cars . just kidding
magnamx-5 is offline  
Old 07-28-2006, 09:40 AM
  #11  
Junior Member
iTrader: (1)
 
BrokeEnthusiast's Avatar
 
Join Date: Feb 2006
Location: Nashville, TN
Posts: 406
Total Cats: 0
Default

did you retard your timing to 6* before the install? that might be why your running bad???
BrokeEnthusiast is offline  
Old 07-28-2006, 10:26 AM
  #12  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,494
Total Cats: 4,080
Default

You'd take the hose off the hard line that feeds into the GREEN arrow.

Put that end into the OFFSET fitting of the FMU.

the CENTER fitting of the FMU should go back into the hardline.


Basically the fuel is fed into the rail, closest to the fans.

from there it exits near the firewall.

then it should travel into the offset fitting of the fmu

and leave the fmu out the center fitting into the return line.
Braineack is offline  
Old 07-28-2006, 02:00 PM
  #13  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

Originally Posted by BrokeEnthusiast
did you retard your timing to 6* before the install? that might be why your running bad???
I've got the bipes....set up like this for now:

Open
Open
Open
Closed
Open
Open
Closed
Closed
Closed
Open
 
Old 07-28-2006, 02:22 PM
  #14  
Boost Czar
iTrader: (62)
 
Braineack's Avatar
 
Join Date: May 2005
Location: Chantilly, VA
Posts: 79,494
Total Cats: 4,080
Default

most of us dont have our index cards handy
Braineack is offline  
Old 07-28-2006, 02:33 PM
  #15  
ruger988
Guest
 
Posts: n/a
Total Cats: 0
Default

Originally Posted by braineack
most of us dont have our index cards handy

SORRY (THAT'S A LINK BY THE WAY)
 
Related Topics
Thread
Thread Starter
Forum
Replies
Last Post
StratoBlue1109
Miata parts for sale/trade
21
09-30-2018 01:09 PM
viriiguy
General Miata Chat
5
09-28-2015 07:39 PM
JesseTheNoob
WTB
4
09-11-2015 01:25 PM



Quick Reply: Need Help Fast, Anyone With A Greddy!!!!



All times are GMT -4. The time now is 11:01 AM.