probably not to code, but if that cable is good enough for my dryer it's good enough to weld with.
I did the same thing, handy tool for finding weld power near any dryer.
I believe the other outlet is a 15/20A 220, I would not try to run the compressor on that but it shouldn't burn a house down, if it's to code. You won't be running it on it if it's too small, it will pop every time it tries to start. I'd check the wire gauge behind the plate if you are super worried.
I did the same thing, handy tool for finding weld power near any dryer.
I believe the other outlet is a 15/20A 220, I would not try to run the compressor on that but it shouldn't burn a house down, if it's to code. You won't be running it on it if it's too small, it will pop every time it tries to start. I'd check the wire gauge behind the plate if you are super worried.
I'm nearly certain that's a 20A wall AC plug, I used one to mine bitcoins when I had no more circuits free. I think that compressor wants 25A max, though 30A is probably a better margin.
Wall outlets are meant to be derated 20% when run on a constant load, more than 3hrs. You are already over the limit without even taking that into consideration.
If your house is wired proper it will pop the breaker immediately, if not it might start fires somewhere exposed if your lucky, down inside the wall if you're not.
Either way, the added resistance will probably lower the running voltage enough to totally **** the capacitors within a week. I've replaced three start capacitors, all nice quality ones, before I finally convinced a customer to do it right.
It's been fine since, well the motor runs at least. Never buy a puma compressor.
Wall outlets are meant to be derated 20% when run on a constant load, more than 3hrs. You are already over the limit without even taking that into consideration.
If your house is wired proper it will pop the breaker immediately, if not it might start fires somewhere exposed if your lucky, down inside the wall if you're not.
Either way, the added resistance will probably lower the running voltage enough to totally **** the capacitors within a week. I've replaced three start capacitors, all nice quality ones, before I finally convinced a customer to do it right.
It's been fine since, well the motor runs at least. Never buy a puma compressor.
Thread Starter
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Ugh. So I should rewire? Or probably ask the landlord to?
And yea. That guy runs a BP. And a ford 9 inch. Search worlds fastest miata. I dont remember the link.
And yea. That guy runs a BP. And a ford 9 inch. Search worlds fastest miata. I dont remember the link.
Yeah, I would. Either that or maybe find a smaller compressor motor if you don't need all the CFM. I think 3-5hp motor would fit under that 20A circuit.
If I had to guess from amps I'd say that's a 6-7 horse motor you've got now.
If I had to guess from amps I'd say that's a 6-7 horse motor you've got now.
So it does...
Well, maybe might get a slightly more efficient 5HP motor? My numbers were assuming 100% efficiency in watt/hp conversion. Whoops.
What you are looking for is something with a run amps around 15-18 and a start up to 20A, maybe a little more.
Well, maybe might get a slightly more efficient 5HP motor? My numbers were assuming 100% efficiency in watt/hp conversion. Whoops.
What you are looking for is something with a run amps around 15-18 and a start up to 20A, maybe a little more.
You should be able to, the puma compressor mentioned earlier got a very nice baldor, spendy too.
Mounting plate might need an adapter plate, but it shouldn't be more than you can handle.
https://lawrence.craigslist.org/tls/5256196129.html
Check that, 5HP with 15A. That would work beautiful.
Mounting plate might need an adapter plate, but it shouldn't be more than you can handle.
https://lawrence.craigslist.org/tls/5256196129.html
Check that, 5HP with 15A. That would work beautiful.
Thread Starter
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Yeah, that should work. I don't know if I'd trust a harbor freight electric motor though.
Check your Craigslist. Old dudes stash these things.
Then again, there might be less farm equipment near you...
Check your Craigslist. Old dudes stash these things.
Then again, there might be less farm equipment near you...
Thread Starter
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Bet that would fit in a flat rate box.
Let me see what the mount is when I get home. If it is standard this might be easier than i thought.
Let me see what the mount is when I get home. If it is standard this might be easier than i thought.







50% of the posts in here are aidan double and triple posting while talking to himself.