Notices
Build Threads Building a motor? Post the progress here.

TSE EFR NB2 Build Thread

Old May 18, 2017 | 09:28 PM
  #721  
EO2K's Avatar
Elite Member
iTrader: (37)
 
Joined: Apr 2010
Posts: 10,477
Total Cats: 1,924
From: Very NorCal
Default

I don't know what you are talking about.

Old May 18, 2017 | 09:37 PM
  #722  
ridethecliche's Avatar
Elite Member
iTrader: (2)
 
Joined: Aug 2016
Posts: 3,890
Total Cats: 146
From: New Fucking Jersey
Default

Err, I though the guy in the mustard costume was hulk hogan for a second and I got very very confused.
Old May 18, 2017 | 09:59 PM
  #723  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

Originally Posted by EO2K
I don't know what you are talking about.
Old May 19, 2017 | 12:36 AM
  #724  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

On a more serious note, I'm having an issue with my oil temp gauge reading 230-255 all the time. Like, when I go to start the car up in the morning, I turn the key to let the fuel pump prime and the gauge says 23x. So would this be an issue with the sensor or with the gauge itself?
Old May 19, 2017 | 04:15 AM
  #725  
codrus's Avatar
Elite Member
 
Joined: Mar 2007
Posts: 5,298
Total Cats: 884
From: Santa Clara, CA
Default

Originally Posted by MiataMan00
On a more serious note, I'm having an issue with my oil temp gauge reading 230-255 all the time. Like, when I go to start the car up in the morning, I turn the key to let the fuel pump prime and the gauge says 23x. So would this be an issue with the sensor or with the gauge itself?
It could be either, or the wiring between them.

--Ian
Old May 19, 2017 | 11:14 AM
  #726  
aidandj's Avatar
SADFab Destructive Testing Engineer
iTrader: (5)
 
Joined: Apr 2014
Posts: 18,643
Total Cats: 1,870
From: Beaverton, USA
Default

What gauge. I would start with replacing the wiring. Thats the cheapest option. Then sensor.
Old May 19, 2017 | 11:25 AM
  #727  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

https://m.summitracing.com/parts/IZL-MS9108W

I have a feeling the wire coming from the sensor melted or something.
Old May 19, 2017 | 11:25 AM
  #728  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

https://m.summitracing.com/parts/IZL-MS9108W

I have a feeling the wire coming from the sensor melted or something.

Edit: oops, double post.
Old May 19, 2017 | 01:24 PM
  #729  
codrus's Avatar
Elite Member
 
Joined: Mar 2007
Posts: 5,298
Total Cats: 884
From: Santa Clara, CA
Default

Where is the gauge, and where is the sensor routed? Is it consistently broken, or just intermittent?

Start by checking for physical damage. If it looks OK, then unplug the sensor from the gauge and use your DVM to check the resistance across it. (it's a thermistor, right? Not a thermocouple?). That'll tell you if it's the gauge or the sensor.

--Ian
Old May 19, 2017 | 02:35 PM
  #730  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

You can see where the gauge is in the t-hill vid (under the radio). The sensor wire is routed through the firewall. I put the sensor itself in the drain plug, so I drilled a hole through the drain plug and stuck it in there. The gauge constantly shows over 230. But it does move up to 255ish. I have no idea what the difference is between a terminator and a thermocouple. I'll Google it. But it just looks like a brass nub basically. I posted a pic of the sensor a couple pages back or something.
Old May 19, 2017 | 02:46 PM
  #731  
shuiend's Avatar
mkturbo.com
iTrader: (24)
 
Joined: May 2006
Posts: 15,235
Total Cats: 1,700
From: Charleston SC
Default

I would say it is probably something to do with grounding. How many wires is the sensor?
Old May 19, 2017 | 02:49 PM
  #732  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

1 wire
Old May 19, 2017 | 02:57 PM
  #733  
shuiend's Avatar
mkturbo.com
iTrader: (24)
 
Joined: May 2006
Posts: 15,235
Total Cats: 1,700
From: Charleston SC
Default

Originally Posted by MiataMan00
1 wire
It could be a possible issue with the sensor not grounding correctly through the drain bolt. Or it could be some of the covering on the wire has rubbed off where it goes through the firewall and could be touching metal.
Old May 19, 2017 | 03:49 PM
  #734  
EO2K's Avatar
Elite Member
iTrader: (37)
 
Joined: Apr 2010
Posts: 10,477
Total Cats: 1,924
From: Very NorCal
Default

Dollars to donuts its the ground at the sensor.

Attach a wire to a known, good, solid, clean ground point somewhere on the car. Strip back 2"+ of insulation off the other end of said wire and wrap it around the exposed metal BODY of the sensor, preferably around the threaded portion that is exposed becauseNPT. Secure with small hose clamp. Report results.
Old May 19, 2017 | 03:59 PM
  #735  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

will try that tonight. Thanks homies.
Old May 19, 2017 | 05:08 PM
  #736  
codrus's Avatar
Elite Member
 
Joined: Mar 2007
Posts: 5,298
Total Cats: 884
From: Santa Clara, CA
Default

A thermistor is a resistor whose resistance varies with temperature. The gauge for one is basically just an ohmmeter with a different scale on the front. They're really cheap and really simple, most oil & coolant gauges are thermistors.

A thermocouple is a device where two wires of different metals will generate a voltage between them, and that voltage depends on the difference in temperature between the ends. They're more precise and faster than thermistors, but also more expensive and harder to use. The voltage they make is really small, so you need a very precise amplifier circuit to read them. Thermocouples are usually only used for EGT.

Anyway, yes, I agree that the problem is probably related to the 1-wire sensor. Generally speaking, a dedicated ground wire is much better.

--Ian
Old May 19, 2017 | 05:18 PM
  #737  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

Thanks for the insight Ian, im sure that will be helpful for other people browsing my thread as well. I'm basically gonna do what G said and report back.
Old May 21, 2017 | 08:13 PM
  #738  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

Welp, I signed up for a track day at Laguna on the 8th as a reward for finishing finals. I haven't messed with my car yet, too busy studying for next week (finals). But this means ill have the next week off, so I will mess with it then and report back about the grounding situation. I also really need to find out where my downpipe is vibrating. Its driving me nuts.

I also ordered blueprinted front hubs a few days ago in hopes that they will fix my pad knock back issue. Fingers crossed.
Old Jun 2, 2017 | 02:26 PM
  #739  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

The new front hubs came in a couple days ago. I didn't bother to remove my ARP studs from my old hubs and transfer them over. It was a nightmare for me last time I did it so I just ordered the hubs with the studs installed. Anyone want some front ARP studs?


While I was in there, I threw on the drivers side 3' duct. I mentioned in a previous post how I wasn't able to install it at the track due to a stuck bolt. Well, that bolt snapped when I tried to remove it. But thankfully I was able to remove it by using a tiny drill bit and going in diagonally.


I have also had a pretty bad oil leak ever sense I fixed the oil seals. It looks to be coming from right above the oil feed block. Its just really odd that it started happening right after I changed the oil seals What makes it even worse it that to even get to that fitting I have to remove all the stuff below it (oil feed block/line/pressure sender) and that is not easy because I have very little access to it. I have a feeling that its tight and is coming from somewhere else but its the only sport that I can visually see oil coming from.

Old Jun 2, 2017 | 09:31 PM
  #740  
icantlearn's Avatar
Thread Starter
Elite Member
 
Joined: Sep 2015
Posts: 1,939
Total Cats: 118
From: San Jose, CA
Default

I have also not gotten around to fixing the ground issue with my oil temp gauge. But I've been thinking about it. if I insulate the signal wire with rubber, couldnt I just crimp on a ring tounge connector onto the ground wire and do it that way? As opposed to wrapping/taping the ground wire around the brass body of the sensor?

Thread Tools
Search this Thread

All times are GMT -4. The time now is 12:14 AM.